Evaluation of monte carlo to support commissioning of the treatment planning system of new pencil beam scanning proton therapy facilities

被引:0
|
作者
Botnariuc, D. [1 ,2 ]
Court, S. [3 ]
Lourenco, A. [1 ,2 ]
Gosling, A. [3 ]
Royle, G. [1 ]
Hussein, M. [2 ]
Rompokos, V [3 ]
Veiga, C. [1 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, Gower St, London WC1E 6BT, England
[2] Metrol Med Phys Ctr, Natl Phys Lab, Hampton Rd, Teddington TW11 0LW, England
[3] Univ Coll London Hosp NHS Fdn Trust, Radiotherapy Phys Serv, 250 Euston Rd, London NW1 2PG, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 04期
关键词
proton therapy; monte carlo; beam modelling; commissioning; DOSE-CALCULATION; NUCLEAR HALO; SIMULATION; PLATFORM; PERFORMANCE; CHALLENGES; GATE; CODE;
D O I
10.1088/1361-6560/ad1272
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To demonstrate the potential of Monte Carlo (MC) to support the resource-intensive measurements that comprise the commissioning of the treatment planning system (TPS) of new proton therapy facilities. Approach. Beam models of a pencil beam scanning system (Varian ProBeam) were developed in GATE (v8.2), Eclipse proton convolution superposition algorithm (v16.1, Varian Medical Systems) and RayStation MC (v12.0.100.0, RaySearch Laboratories), using the beam commissioning data. All models were first benchmarked against the same commissioning data and validated on seven spread-out Bragg peak (SOBP) plans. Then, we explored the use of MC to optimise dose calculation parameters, fully understand the performance and limitations of TPS in homogeneous fields and support the development of patient-specific quality assurance (PSQA) processes. We compared the dose calculations of the TPSs against measurements (DDTPSvs.Meas.) or GATE (DDTPSvs.GATE) for an extensive set of plans of varying complexity. This included homogeneous plans with varying field-size, range, width, and range-shifters (RSs) (n = 46) and PSQA plans for different anatomical sites (n = 11). Main results. The three beam models showed good agreement against the commissioning data, and dose differences of 3.5% and 5% were found for SOBP plans without and with RSs, respectively. DDTPSvs.Meas. and DDTPSvs.GATE were correlated in most scenarios. In homogeneous fields the Pearson's correlation coefficient was 0.92 and 0.68 for Eclipse and RayStation, respectively. The standard deviation of the differences between GATE and measurements (+/- 0.5% for homogeneous and +/- 0.8% for PSQA plans) was applied as tolerance when comparing TPSs with GATE. 72% and 60% of the plans were within the GATE predicted dose difference for both TPSs, for homogeneous and PSQA cases, respectively. Significance. Developing and validating a MC beam model early on into the commissioning of new proton therapy facilities can support the validation of the TPS and facilitate comprehensive investigation of its capabilities and limitations.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Application of Monte Carlo Simulation for Treatment Planning System Commissioning and Dose Calculation for a Pencil Beam Scanning Proton Therapy System
    Hu, H.
    Liu, H.
    Jia, Y.
    Zheng, Y.
    Ding, S.
    Wang, B.
    Li, Y.
    Huang, X.
    Li, Z.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E860 - E860
  • [2] Validation and Application of a Commercial Proton Monte Carlo Pencil Beam Scanning Treatment Planning System
    Huang, S.
    Maslowski, A.
    Hiltunen, P.
    Lin, L.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E589 - E589
  • [3] A standardized commissioning framework of Monte Carlo dose calculation algorithms for proton pencil beam scanning treatment planning systems
    Chang, Chih-Wei
    Huang, Sheng
    Harms, Joseph
    Zhou, Jun
    Zhang, Rongxiao
    Dhabaan, Anees
    Slopsema, Roelf
    Kang, Minglei
    Liu, Tian
    McDonald, Mark
    Langen, Katja
    Lin, Liyong
    [J]. MEDICAL PHYSICS, 2020, 47 (04) : 1545 - 1557
  • [4] A Golden Beam Data Commissioning Framework of Monte Carlo Dose Calculation Algorithms of Two Pencil Beam Scanning Proton Therapy Treatment Planning Systems
    Chang, C.
    Harms, J.
    Zhang, R.
    Zhou, J.
    Lin, Y.
    Slopsema, R.
    Dhabaan, A.
    Liu, T.
    McDonald, M.
    Langen, K.
    Lin, L.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E167 - E167
  • [5] An Automatic Beam Model Commissioning Method for Monte Carlo Simulations in Pencil-Beam Scanning Proton Therapy
    Qin, N.
    Shen, C.
    Tian, Z.
    Jiang, S.
    Jia, X.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3335 - 3335
  • [6] Experimental Validation and Calculation Benchmark for a Commercial Monte Carlo Pencil Beam Scanning Proton Therapy Treatment Planning System in Water
    Lin, L.
    Huang, S.
    Kang, M.
    Ainsley, C.
    Hiltunen, P.
    Vanderstraeten, R.
    Lindberg, J.
    Siljamaki, S.
    Wareing, T.
    Davis, I.
    Barnett, A.
    McGhee, J.
    Solberg, T.
    McDonough, J.
    Simone, C., II
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3497 - 3497
  • [7] A benchmarking method to evaluate the accuracy of a commercial proton monte carlo pencil beam scanning treatment planning system
    Lin, Liyong
    Huang, Sheng
    Kang, Minglei
    Hiltunen, Petri
    Vanderstraeten, Reynald
    Lindberg, Jari
    Siljamaki, Sami
    Wareing, Todd
    Davis, Ian
    Barnett, Allen
    McGhee, John
    Simone, Charles B., II
    Solberg, Timothy D.
    McDonough, James E.
    Ainsley, Christopher
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (02): : 44 - 49
  • [8] Monte Carlo Dose Verification of Pencil Beam Scanning Proton Therapy
    Giantsoudi, D.
    Clasie, B.
    Grassberger, C.
    Dowdell, S.
    Depauw, N.
    Madden, T.
    Kooy, H.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [9] Commissioning of a synchrotron-based proton beam therapy system for use with a Monte Carlo treatment planning system
    Azcona, Juan-Diego
    Aguilar, Borja
    Perales, Alvaro
    Polo, Ramon
    Zucca, Daniel
    Irazola, Leticia
    Vinals, Alberto
    Cabello, Pablo
    Delgado, Jose-Miguel
    Pedrero, Diego
    Bermudez, Rocio
    Fayos-Sola, Roser
    Huesa-Berral, Carlos
    Burguete, Javier
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2023, 204
  • [10] Commissioning of a Facility-Specific Beam Data Library for a Fast Monte Carlo Code for Pencil Beam Scanning Proton Therapy
    Hong, L.
    Souris, K.
    Cohilis, M.
    Rossomme, S.
    Liu, H.
    Li, Z.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E587 - E587