System identification: a feasible, reliable and valid way to quantify upper limb motor impairments

被引:0
|
作者
van de Ruit, Mark [1 ,2 ]
van der Velden, Levinia L. [2 ]
Onneweer, Bram [2 ,3 ]
Benner, Joyce L. [2 ]
Haarman, Claudia J. W. [4 ,5 ]
Ribbers, Gerard M. [2 ]
Selles, Ruud W. [2 ]
机构
[1] Delft Univ Technol, Dept Biomech Engn, Mekelweg 2, NL-2628 CD Delft, Netherlands
[2] Erasmus MC Univ Med Ctr Rotterdam, Dept Rehabil Med, Doctor Molewaterpl 40, NL-3015 GD Rotterdam, Netherlands
[3] Rijndam Rehabil, Westersingel 300, NL-3015 LJ Rotterdam, Netherlands
[4] Univ Twente, Dept Biomech Engn, Enschede, Netherlands
[5] Hankamp Rehab, Enschede, Netherlands
基金
荷兰研究理事会;
关键词
Viscoelasticity; Biomechanics; Upper limb; Diagnostics; Motor impairments; MODIFIED ASHWORTH SCALE; HUMAN ANKLE STIFFNESS; FUGL-MEYER ASSESSMENT; REFLEX CONTRIBUTIONS; RELIABILITY; SPASTICITY; STROKE; JOINT; ELBOW; ACTIVATION;
D O I
10.1186/s12984-023-01192-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background Upper limb impairments in a hemiparetic arm are clinically quantified by well-established clinical scales, known to suffer poor validity, reliability, and sensitivity. Alternatively, robotics can assess motor impairments by characterizing joint dynamics through system identification. In this study, we establish the merits of quantifying abnormal synergy, spasticity, and changes in joint viscoelasticity using system identification, evaluating (1) feasibility and quality of parametric estimates, (2) test-retest reliability, (3) differences between healthy controls and patients with upper limb impairments, and (4) construct validity. Methods Forty-five healthy controls, twenty-nine stroke patients, and twenty cerebral palsy patients participated. Participants were seated with the affected arm immobilized in the Shoulder-Elbow-Perturbator (SEP). The SEP is a one-degree-of-freedom perturbator that enables applying torque perturbations to the elbow while providing varying amounts of weight support to the human arm. Participants performed either a `do not intervene' or a resist task. Elbow joint admittance was quantified and used to extract elbow viscosity and stiffness. Fifty-four of the participants performed two sessions to establish the test-retest reliability of the parameters. Construct validity was assessed by correlating system identification parameters to parameters extracted using a SEP protocol that objectifies current clinical scales (Re-Arm protocol). Results Feasibility was confirmed by all participants successfully completing the study protocol within similar to 25 min without reporting pain or burden. The parametric estimates were good with a variance-accounted-for of similar to 80%. A fair to excellent test-retest reliability was found (ICC = 0.46 - 0.98) for patients, except for elbow stiffness with full weight support (ICC = 0.35). Compared to healthy controls, patients had a higher elbow viscosity and stiffness during the `do not intervene' task and lower viscosity and stiffness during the resist task. Construct validity was confirmed by a significant (all p < 0.03) but weak to moderate (r = 0.36 - 0.50) correlation with parameters from the Re-Arm protocol. Conclusions This work demonstrates that system identification is feasible and reliable for quantifying upper limb motor impairments. Validity was confirmed by differences between patients and controls and correlations with other measurements, but further work is required to optimize the experimental protocol and establish clinical value.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Virtual Reality Upper Limb Motor and Proprioception Assessment System for Stroke Patients
    Hong, Woongpyo
    Lee, Jongho
    Woong, Choi
    Kim, Jaehyo
    [J]. 2017 IEEE 6TH GLOBAL CONFERENCE ON CONSUMER ELECTRONICS (GCCE), 2017,
  • [32] Touch location and force sensing interactive system for upper limb motor rehabilitation
    Nadia Garcia-Hernandez
    Karely Huerta-Cervantes
    Iram Muñoz-Pepi
    Vicente Parra-Vega
    [J]. Multimedia Tools and Applications, 2022, 81 : 14133 - 14152
  • [33] Priming the motor system enhances the effects of upper limb therapy in chronic stroke
    Barber, P. Alan
    Stinear, Cathy M.
    Coxon, James P.
    Fleming, Melanie K.
    Byblow, Winston D.
    [J]. NEUROLOGY, 2008, 70 (11) : A234 - A234
  • [34] Comparison of EEG measurement of upper limb movement in motor imagery training system
    Arpa Suwannarat
    Setha Pan-ngum
    Pasin Israsena
    [J]. BioMedical Engineering OnLine, 17
  • [35] Priming the motor system enhances the effects of upper limb therapy in chronic stroke
    Stinear, Cathy M.
    Barber, P. Alan
    Coxon, James P.
    Fleming, Melanie K.
    Byblow, Winston D.
    [J]. BRAIN, 2008, 131 : 1381 - 1390
  • [36] Comparison of EEG measurement of upper limb movement in motor imagery training system
    Suwannarat, Arpa
    Pan-ngum, Setha
    Israsena, Pasin
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [37] Touch location and force sensing interactive system for upper limb motor rehabilitation
    Garcia-Hernandez, Nadia
    Huerta-Cervantes, Karely
    Munoz-Pepi, Iram
    Parra-Vega, Vicente
    [J]. MULTIMEDIA TOOLS AND APPLICATIONS, 2022, 81 (10) : 14133 - 14152
  • [38] A Novel and Clinically Feasible Instrument for Quantifying Upper Limb Muscle Tone and Motor Function via Indirect Measure Methods
    Hsu, Chieh-Hsiang
    Lin, Yu-Chen
    Hsu, Hsiu-Yun
    Chieh, Hsiao-Feng
    Lin, Chien-Ju
    Ling, Shih-Fu
    Su, Fong-Chin
    Kuo, Li-Chieh
    [J]. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2022, 10
  • [39] Somatosensory impairments in the upper limb post stroke: Distribution, impact of visuo-spatial neglect and association with motor function
    Meyer, S.
    De Bruyn, N.
    Lafosse, C.
    Van Dijk, M.
    Michielsen, M.
    Thijs, L.
    Truyens, V
    Oostra, K.
    Krumlinde-Sundholm, L.
    Peeters, A.
    Thijs, V
    Feys, H.
    Verheyden, G.
    [J]. INTERNATIONAL JOURNAL OF STROKE, 2015, 10 : 56 - 56
  • [40] A Portable and Cost-Effective Upper Extremity Rehabilitation System for Individuals with Upper Limb Motor Deficits
    Lin, Feng
    Ajay, Jerry
    Langan, Jeanne
    Cavuoto, Lora
    Nwogu, Ifeoma
    Subryan, Heamchand
    Xu, Wenyao
    [J]. 2016 IEEE WIRELESS HEALTH (WH), 2016, : 157 - 163