Point of use SERS-based lateral flow test for pathogenic infections

被引:1
|
作者
Hassanain, Waleed A. [1 ]
Sloan-Dennison, Sian [1 ]
Spoors, Julia [2 ]
Johnson, Christopher L. [2 ]
Keegan, Neil [2 ]
Faulds, Karen [1 ]
Graham, Duncan [1 ]
机构
[1] Univ Strathclyde, Technol & Innovat Ctr, Dept Pure & Appl Chem, Glasgow G1 1RD, Lanark, Scotland
[2] Newcastle Univ, Translat & Clin Res Inst, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1117/12.2675805
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Lateral flow immunoassays are paper-based tests that can be used to detect different pathogenic biomarkers at the point-of-use. Conventionally, detection antibodies labelled with gold nanoparticles form sandwich immunoassays between the target antigen and capture antibody on the test line/spot when the biomarker is present in a sample. They provide rapid, visual and yes/no answers based on the appearance of the gold nanoparticles on the strip. However, lateral flow tests suffer from poor sensitivity which can lead to false negative results when the biomarker concentration is below the visual threshold of the test, especially at early infection stages. They also can't accurately quantify the biomarker concentration which is important in monitoring the progression of an infection or the effectiveness of a treatment. Accordingly, lateral flow test should be combined with a read-out system that is convenient for points of use and could enable the accurate, sensitive and rapid quantification of the test results. In this work, we discuss the integration of surface enhanced Raman scattering technique with the lateral flow test in one platform to improve the test sensitivity and quantification capability, while maintaining the user-friendly and point-of-use features the lateral flow test provides. We have applied this approach for the detection of Clostridioides difficile and SARS-COV-2, as demonstrators for pathogenic infections, using new recognition elements in the test as a proof-of-concept.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] SERS-Based Ultrasensitive Lateral Flow Assay for Quantitative Sensing of Protein Biomarkers
    Gunawardhana, Loku
    Kourentzi, Katerina
    Danthanarayana, Adheesha N.
    Brgoch, Jakoah
    Shan, Xiaonan
    Willson, Richard C.
    Wei-Chuan Shih
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2021, 27 (05)
  • [2] The development and application of SERS-based lateral flow immunochromatography in the field of food safety
    Liu, Wenxi
    Wang, Hao
    Zhong, Wenhui
    Zhang, Yichun
    Liu, Yingyue
    Gao, Xibao
    Yan, Mengmeng
    Zhu, Chao
    MICROCHIMICA ACTA, 2025, 192 (04)
  • [3] Rapid and Sensitive SERS-Based Lateral Flow Test for SARS-CoV2-Specific IgM/IgG Antibodies
    Srivastav, Supriya
    Dankov, Asen
    Adanalic, Mujo
    Grzeschik, Roland
    Vi Tran
    Pagel-Wieder, Sibylle
    Gessler, Frank
    Spreitzer, Ingo
    Scholz, Tatjana
    Schnierle, Barbara
    Anastasiou, Olympia E.
    Dittmer, Ulf
    Schluecker, Sebastian
    ANALYTICAL CHEMISTRY, 2021, 93 (36) : 12391 - 12399
  • [4] Simultaneous Detection ofListeria monocytogenesandSalmonella typhimuriumby a SERS-Based Lateral Flow Immunochromatographic Assay
    Zhengzong Wu
    Food Analytical Methods, 2019, 12 : 1086 - 1091
  • [5] Rapid and sensitive detection of zearalenone in corn using SERS-based lateral flow immunosensor
    Yin, Limei
    You, Tianyan
    El-Seedi, Hesham R.
    El-Garawani, Islam M.
    Guo, Zhiming
    Zou, Xiaobo
    Cai, Jianrong
    FOOD CHEMISTRY, 2022, 396
  • [6] Development of a SERS-Based Rapid Vertical Flow Assay for Point-of Care Diagnostics
    Clarke, O. J. R.
    Goodall, B. L.
    Hui, H. P.
    Vats, N.
    Brosseau, C. L.
    ANALYTICAL CHEMISTRY, 2017, 89 (03) : 1405 - 1410
  • [7] A SERS-based immune-nanoprobe for ultrasensitive detection of glycinin via a lateral flow assay
    Huang, Pengbo
    Yang, Shuo
    Chen, Zixin
    Shang, Achen
    Liu, Deguo
    Xi, Jun
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 305
  • [8] RETRACTED ARTICLE: A SERS-based lateral flow assay for the stroke biomarker S100-β
    Ying Wang
    Yajun Hou
    Hanxia Li
    Mingfeng Yang
    Peng Zhao
    Baoliang Sun
    Microchimica Acta, 2019, 186
  • [9] Simultaneous Detection of Dual Nucleic Acids Using a SERS-Based Lateral Flow Assay Biosensor
    Wang, Xiaokun
    Choi, Namhyun
    Cheng, Ziyi
    Ko, Juhui
    Chen, Lingxin
    Choo, Jaebum
    ANALYTICAL CHEMISTRY, 2017, 89 (02) : 1163 - 1169
  • [10] Retraction Note to: A SERS-based lateral flow assay for the stroke biomarker S100-β
    Ying Wang
    Yajun Hou
    Hanxia Li
    Mingfeng Yang
    Peng Zhao
    Baoliang Sun
    Microchimica Acta, 2021, 188