Attack Angle Parametrization for Capacity Augmentation and Wake Management by Vortex Generators in Finned Compact Heat Exchangers

被引:0
|
作者
Arora, Amit [1 ]
Subbarao, P. M. V. [2 ]
机构
[1] Malaviya Natl Inst Technol Jaipur, Dept Mech Engn, Jaipur 302017, Rajasthan, India
[2] Indian Inst Technol Delhi, Dept Mech Engn, New Delhi 110016, India
关键词
energy systems; extended surfaces/fins; heat exchangers; heat transfer enhancement; AIR-SIDE PERFORMANCE; TRANSFER ENHANCEMENT; PLATE-FIN; BANK FIN; TUBE; FLOW; LOCATION; ARRAYS;
D O I
10.1115/1.4063046
中图分类号
O414.1 [热力学];
学科分类号
摘要
Enhancing gas-side thermal conductance is essential for the compact sizing of finned-tube heat exchangers, and this study attempts it by integrating vortex generators. The orientation of the vortex generators, which is defined by its attack angle, has a strong bearing on the degree of augmentation. As the energy efficiency keeps varying with the attack angle, the thrust of this investigation is to identify the best attack angle(s) for the stipulated task. For that purpose, four distinct attack angles (i.e., 15 deg, 30 deg, 45 deg and 60 deg), representing the entire effective range, are considered. Since spatial positioning of the generators too has a strong bearing on energy efficiency, therefore, its effect is duly accounted for a comprehensive investigation. For the selection of optimal designs, regression-based phenomenological models are used as they apply thermo-hydraulic trade-offs. After determining the best angle(s), a study is carried out to evaluate their robustness under varying operating conditions. Although phenomenological models are adequate for design optimization, they do not describe the physics of thermo-hydraulic enhancement. Therefore, a study explaining the bearing of design modifications on the local characteristics too is carried out. Additionally, a study discussing the effect of generators' attack angle on heat transfer over the wake-affected surfaces, which has a predominant existence in baseline flows, is reported. It has been found that thermal augmentation over the said surfaces is the key to compact sizing of the system. For a selected wake-region deployment, the highest relative Colburn j-factor corresponding to wake-affected fin equals 3.07 at the specified Reynolds number.
引用
收藏
页数:12
相关论文
共 34 条
  • [31] OPTIMIZATION OF THE ANGLE OF ATTACK OF DELTA-WINGLET VORTEX GENERATORS VERA BANK OF ELLIPTICAL-TUBES HEAT EXCHANGER
    Godazandeh, K.
    Ansari, M. H.
    Godazandeh, B.
    Ashjaee, M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 8A, 2014,
  • [32] Thermal-hydraulic performance optimization of inline and staggered fin-tube compact heat exchangers applying longitudinal vortex generators
    Salviano, Leandro O.
    Dezan, Daniel J.
    Yanagihara, Jurandir I.
    APPLIED THERMAL ENGINEERING, 2016, 95 : 311 - 329
  • [33] Study of Flow and Heat Transfer Characteristics of non-periodical attack angle in Narrow Rectangular Channel with Longitudinal Vortex generators
    Wang, L.
    Huang, J.
    6TH INTERNATIONAL SYMPOSIUM ON MULTIPHASE FLOW, HEAT MASS TRANSFER AND ENERGY CONVERSION, 2010, 1207 : 513 - +
  • [34] Effect of Flow Attack Angle of V-Ribs Vortex Generators in a Square Duct on Flow Structure, Heat Transfer, and Performance Improvement
    Boonloi, Amnart