Inadequate gastric preparation and its associated factors for magnetically controlled capsule endoscopy

被引:2
|
作者
Kong, Qing-Zhou [1 ]
Peng, Cheng [1 ]
Li, Zhen [1 ]
Tian, Bao-Ling [1 ]
Li, Yue-Yue [1 ]
Chen, Fei-Xue [1 ,2 ,3 ]
Zuo, Xiu-Li [1 ,2 ,3 ]
Li, Yan-Qing [1 ,2 ,3 ]
机构
[1] Shandong Univ, Qilu Hosp, Dept Gastroenterol, Jinan, Shandong, Peoples R China
[2] Shandong Prov Clin Res Ctr Digest Dis, Jinan, Shandong, Peoples R China
[3] Shandong Univ, Qilu Hosp, Robot Engn Lab Precise Diag & Therapy GI Tumor, Jinan, Shandong, Peoples R China
基金
国家重点研发计划;
关键词
magnetically controlled capsule endoscopy; gastric disease; preparation; proton pump inhibitor; simethicone; CONVENTIONAL GASTROSCOPY; IMPROVING VISIBILITY; ACID SUPPRESSANTS; N-ACETYLCYSTEINE; PREMEDICATION; SIMETHICONE; RABEPRAZOLE; PRONASE;
D O I
10.3389/fphar.2023.1184754
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Goals: To explore factors associated with inadequate gastric preparation for MCE.Background: Factors associated with inadequate gastric preparation for magnetically controlled capsule endoscopy (MCE) remains unclear.Study: Data of patients who underwent MCE from June 2021 to July 2022 were prospectively collected. The gastric cleanliness score (GCS) of the six stomach regions (gastric cardia, fundus, body, angulus, antrum, and pylorus) was recorded. Patients with GCS score =18 were defined as the adequate preparation. Factors related to inadequate gastric preparation were analyzed using a logistic regression model with estimated odds ratios (OR).Results: The mean GCS score of 211 patients was 17.01 & PLUSMN; 2.82. In the multivariable analysis, proton pump inhibitor (PPI) use (OR 3.57; 95% CI 1.69-7.95; p < 0.01) and premedication time after administering simethicone <30 min (OR 2.86; 95% CI 1.10-7.39; p = 0.03) were independent risk factors for inadequate gastric preparation. Comparing the gastric cleanliness of different locations, the median GCS of the lower stomach [10.00, IQR (9.50, 11.00)] was significantly higher than that of the upper stomach [7.00, IQR (6.00, 8.00)] (p <0.001).Conclusion: PPI use and inadequate premedication time (<30 min) may reduce the quality of gastric preparation for MCE. The type, dose, duration of medication, and discontinuation time of PPIs was well worth further exploration. Appropriate control of the type and time of premedication may be the key to improving overall gastric cleanliness.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Magnetically controlled capsule endoscopy for the evaluation of the stomach. Are we ready for this?
    Spada, Cristiano
    Hassan, Cesare
    Costamagna, Guido
    DIGESTIVE AND LIVER DISEASE, 2018, 50 (10) : 1047 - 1048
  • [22] Does magnetically assisted capsule endoscopy improve small bowel capsule endoscopy completion rate? A randomised controlled trial
    Hale, Melissa F.
    Drew, Kaye
    Sidhu, Reena
    McAlindon, Mark E.
    ENDOSCOPY INTERNATIONAL OPEN, 2016, 4 (02) : E215 - E221
  • [23] SPRITE ZERO® FOR BETTER GASTRIC PREPARATION FOR CAPSULE ENDOSCOPY EXAMINATION: A RANDOMIZED CONTROLLED PILOT STUDY
    Zhu, Jia-Hui
    Qian, Yang-Yang
    Liu, Xiao
    Liao, Zhuan
    GASTROINTESTINAL ENDOSCOPY, 2021, 93 (06) : AB37 - AB37
  • [24] Real-time identification of gastric lesions and anatomical landmarks by artificial intelligence during magnetically controlled capsule endoscopy
    Pan, Jun
    Xia, Ji
    Jiang, Bin
    Zhang, Hang
    Zhang, Hao
    Li, Zhao-Shen
    Liao, Zhuan
    ENDOSCOPY, 2022, 54 (11) : E622 - E623
  • [25] Detachable string magnetically controlled capsule endoscopy for complete viewing of the esophagus and stomach
    Chen, Yi-Zhi
    Pan, Jun
    Luo, Yuan-Yuan
    Jiang, Xi
    Zou, Wen-Bin
    Qian, Yang-Yang
    Zhou, Wei
    Liu, Xiao
    Li, Zhao-Shen
    Liao, Zhuan
    ENDOSCOPY, 2019, 51 (04) : 360 - 364
  • [26] Current and future role of magnetically assisted gastric capsule endoscopy in the upper gastrointestinal tract
    Ching, Hey-Long
    Hale, Melissa Fay
    McAlindon, Mark Edward
    THERAPEUTIC ADVANCES IN GASTROENTEROLOGY, 2016, 9 (03) : 313 - 321
  • [27] Screening for gastric cancer with magnetically controlled capsule gastroscopy in asymptomatic individuals
    Zhao, An-Jing
    Qian, Yang-Yang
    Sun, Hui
    Hou, Xi
    Pan, Jun
    Liu, Xiao
    Zhou, Wei
    Chen, Yi-Zhi
    Jiang, Xi
    Li, Zhao-Shen
    Liao, Zhuan
    GASTROINTESTINAL ENDOSCOPY, 2018, 88 (03) : 466 - +
  • [28] NOVEL USE OF MAGNETICALLY CONTROLLED CAPSULE ENDOSCOPY AND ARTIFICAL INTELLIGENCE VIDEO ANALYSIS TO STUDY GASTRIC MOTILTY IN GASTROPARESIS AND FUNCTIONAL DYSPEPSIA
    Kamath, Rahul
    Ehrlich, Dean
    Mahurkar-Joshi, Swapna
    Sedarat, Alireza
    Sohn, Jessica
    Chang, Lin
    GASTROENTEROLOGY, 2023, 164 (06) : S630 - S630
  • [29] Magnetically Controlled Capsule Endoscopy for Assessment of Antiplatelet Therapy-Induced Gastrointestinal Injury
    Han, Yaling
    Liao, Zhuan
    Li, Yi
    Zhao, Xianxian
    Ma, Shuren
    Bao, Dan
    Qiu, Miaohan
    Deng, Jie
    Wang, Jinhai
    Qu, Peng
    Jiang, Chunmeng
    Jia, Shaobin
    Yang, Shaoqi
    Ru, Leisheng
    Feng, Jia
    Gao, Wei
    Huang, Yonghui
    Tao, Ling
    Han, Ying
    Yang, Kan
    Wang, Xiaoyan
    Zhang, Wenjuan
    Wang, Bangmao
    Li, Yue
    Yang, Youlin
    Li, Junxia
    Sheng, Jiangqiu
    Ma, Yitong
    Cui, Min
    Ma, Sicong
    Wang, Xiaozeng
    Li, Zhaoshen
    Stone, Gregg W.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (02) : 116 - 128
  • [30] A Multi-task Neural Network for Image Recognition in Magnetically Controlled Capsule Endoscopy
    Xu, Ting
    Li, Yuan-Yi
    Huang, Fang
    Gao, Min
    Cai, Can
    He, Song
    Wu, Zhi-Xuan
    DIGESTIVE DISEASES AND SCIENCES, 2024, 69 (11) : 4231 - 4239