Inadequate gastric preparation and its associated factors for magnetically controlled capsule endoscopy

被引:2
|
作者
Kong, Qing-Zhou [1 ]
Peng, Cheng [1 ]
Li, Zhen [1 ]
Tian, Bao-Ling [1 ]
Li, Yue-Yue [1 ]
Chen, Fei-Xue [1 ,2 ,3 ]
Zuo, Xiu-Li [1 ,2 ,3 ]
Li, Yan-Qing [1 ,2 ,3 ]
机构
[1] Shandong Univ, Qilu Hosp, Dept Gastroenterol, Jinan, Shandong, Peoples R China
[2] Shandong Prov Clin Res Ctr Digest Dis, Jinan, Shandong, Peoples R China
[3] Shandong Univ, Qilu Hosp, Robot Engn Lab Precise Diag & Therapy GI Tumor, Jinan, Shandong, Peoples R China
基金
国家重点研发计划;
关键词
magnetically controlled capsule endoscopy; gastric disease; preparation; proton pump inhibitor; simethicone; CONVENTIONAL GASTROSCOPY; IMPROVING VISIBILITY; ACID SUPPRESSANTS; N-ACETYLCYSTEINE; PREMEDICATION; SIMETHICONE; RABEPRAZOLE; PRONASE;
D O I
10.3389/fphar.2023.1184754
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Goals: To explore factors associated with inadequate gastric preparation for MCE.Background: Factors associated with inadequate gastric preparation for magnetically controlled capsule endoscopy (MCE) remains unclear.Study: Data of patients who underwent MCE from June 2021 to July 2022 were prospectively collected. The gastric cleanliness score (GCS) of the six stomach regions (gastric cardia, fundus, body, angulus, antrum, and pylorus) was recorded. Patients with GCS score =18 were defined as the adequate preparation. Factors related to inadequate gastric preparation were analyzed using a logistic regression model with estimated odds ratios (OR).Results: The mean GCS score of 211 patients was 17.01 & PLUSMN; 2.82. In the multivariable analysis, proton pump inhibitor (PPI) use (OR 3.57; 95% CI 1.69-7.95; p < 0.01) and premedication time after administering simethicone <30 min (OR 2.86; 95% CI 1.10-7.39; p = 0.03) were independent risk factors for inadequate gastric preparation. Comparing the gastric cleanliness of different locations, the median GCS of the lower stomach [10.00, IQR (9.50, 11.00)] was significantly higher than that of the upper stomach [7.00, IQR (6.00, 8.00)] (p <0.001).Conclusion: PPI use and inadequate premedication time (<30 min) may reduce the quality of gastric preparation for MCE. The type, dose, duration of medication, and discontinuation time of PPIs was well worth further exploration. Appropriate control of the type and time of premedication may be the key to improving overall gastric cleanliness.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Gastric preparation for magnetically controlled capsule endoscopy: A prospective, randomized single-blinded controlled trial
    Zhu, Shu-Guang
    Qian, Yang-Yang
    Tang, Xin-Ying
    Zhu, Qian-Qian
    Zhou, Wei
    Du, Han
    An, Wei
    Su, Xiao-Ju
    Zhao, An-Jing
    Ching, Hey-Long
    McAlindon, Mark Edward
    Li, Zhao-Shen
    Liao, Zhuan
    DIGESTIVE AND LIVER DISEASE, 2018, 50 (01) : 42 - 47
  • [2] Development and Application of Magnetically Controlled Capsule Endoscopy in Detecting Gastric Lesions
    Zhang, Yaoping
    Zhang, Yanning
    Huang, Xiaojun
    GASTROENTEROLOGY RESEARCH AND PRACTICE, 2021, 2021
  • [3] Aspiration of a Magnetically Controlled Capsule Endoscopy
    Dan, Tang
    Song, Dandan
    Linghu, Enqiang
    GASTROENTEROLOGY, 2023, 164 (06) : E30 - E31
  • [4] Use of artificial intelligence for detection of gastric lesions by magnetically controlled capsule endoscopy
    Xia, Ji
    Xia, Tian
    Pan, Jun
    Gao, Fei
    Wang, Shuang
    Qian, Yang-Yang
    Wang, Heng
    Zhao, Jie
    Jiang, Xi
    Zou, Wen-Bin
    Wang, Yuan-Chen
    Zhou, Wei
    Li, Zhao-Shen
    Liao, Zhuan
    GASTROINTESTINAL ENDOSCOPY, 2021, 93 (01) : 133 - +
  • [5] USE OF ARTIFICIAL INTELLIGENCE FOR DETECTION OF GASTRIC LESIONS BY MAGNETICALLY CONTROLLED CAPSULE ENDOSCOPY
    Xia, Ji
    Xia, Tian
    Pan, Jun
    Gao, Fei
    Wang, Shuang
    Wang, Heng
    Qian, Yang-Yang
    Zhao, Jie
    Jiang, Xi
    Jiang, Bin
    Ru, Nan
    Zhu, Jia-Hui
    Liu, Xiao
    Zou, Wen-Bin
    Zhou, Wei
    Li, ZhaoShen
    Liao, Zhuan
    GASTROINTESTINAL ENDOSCOPY, 2020, 91 (06) : AB253 - AB253
  • [6] The operation training for magnetically controlled capsule endoscopy
    Hu, Jinlong
    Huang Yunpeng
    Wang, Shupeng
    Sun, Siyu
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2021, 33 (01) : 46 - 49
  • [7] Accuracy of Magnetically Controlled Capsule Endoscopy, Compared With Conventional Gastroscopy, in Detection of Gastric Diseases
    Liao, Zhuan
    Hou, Xi
    Lin-Hu, En-Qiang
    Sheng, Jian-Qiu
    Ge, Zhi-Zheng
    Jiang, Bo
    Hou, Xiao-Hua
    Liu, Ji-Yong
    Li, Zhen
    Huang, Qi-Yang
    Zhao, Xiao-Jun
    Li, Na
    Gao, Yun-Jie
    Zhang, Yao
    Zhou, Jie-Qiong
    Wang, Xin-Ying
    Liu, Jun
    Xie, Xiao-Ping
    Yang, Cong-Mei
    Liu, Hua-Lin
    Sun, Xiao-Tian
    Zou, Wen-Bin
    Li, Zhao-Shen
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2016, 14 (09) : 1266 - +
  • [8] Effect of metoclopramide on gastrointestinal of magnetically controlled capsule endoscopy
    Chen, Jui-Yen
    Wu, Jia-Chuan
    Yang, Xiao-Qiao
    Ye, Li-Fang
    Tan, Wen-Hui
    Liang, Biao
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2017, 32 : 257 - 257
  • [9] Feasibility of Novel Magnetically Controlled Cable Capsule Endoscopy System In Vitro Experiments for Gastric Examination
    Zhang, Yaoping
    Qu, Lina
    Gou, Yani
    Hao, Jinyong
    Huang, Xiaojun
    GASTROENTEROLOGY RESEARCH AND PRACTICE, 2022, 2022
  • [10] The Clinical Utility of Magnetically Controlled Capsule Endoscopy in Pediatric Patients
    Tang, Yanping
    Cheng, Shidan
    Wang, Lifu
    Xu, Beili
    Gong, Biao
    Shen, Ruizhe
    GASTROINTESTINAL ENDOSCOPY, 2016, 83 (05) : AB299 - AB300