Design and performance of a novel closed-loop erosion-corrosion tester

被引:2
|
作者
Adnane, Eljersifi [1 ,2 ]
Abdelouahed, Chbihi [1 ]
Nawal, Semlal [3 ]
Hassan, Bouaouine [2 ]
Sanae, Naamane [1 ]
机构
[1] Mohammed VI Polytech Univ UM6P, Moroccan Fdn Adv Sci Innovat & Res MAScIR, Lot 660,Hay Moulay Rachid, Benguerir 43150, Morocco
[2] Mohammed V Univ, Mohammedia Sch Engineers EMI, Ave Ibn Sina BP 765 Agdal, Rabat, Morocco
[3] OCPGrp SA, 2-4 rue Al Abtal Hay Erraha, Casablanca 20200, Morocco
关键词
Wear; Erosion; Corrosion; Erosion-corrosion; Tester; Slurry pot; Stainless steel; High chromium cast iron; Impeller; SLURRY EROSION; STAINLESS-STEELS; CAST IRONS; WEAR; BEHAVIOR; RESISTANCE; IMPACT; PUMP; MECHANISM; TRIBOCORROSION;
D O I
10.1016/j.triboint.2023.109029
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In this paper, the authors present a novel closed-loop erosion-corrosion tester designed for the study of wear damage on rotary components, specifically the impellers of centrifugal pumps. This tester improves upon standard slurry pot erosion testers by using a closed loop configuration that allows for the constant use of new particles, thus eliminating the particle blunting limitation faced by these testers. The shape of the sample holder is also altered and allows for better particle distribution and the simultaneous testing of 4 samples at different impingement angles. The tests were carried out on a AISI 1045 carbon steel to verify the repeatability of results. A study on the erosion and erosion-corrosion resistance was then performed on a 304 L stainless steel and a ferritic high chromium cast iron. Results showed that the high chromium cast iron exhibited higher erosion and erosion-corrosion resistance except at 90 degrees angles where its brittle nature made it more vulnerable to erosion and prone to cracking which also affected its corrosion resistance.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Comparative study of erosion-corrosion performance on a range of stainless steels
    Giourntas, L.
    Hodgkiess, T.
    Galloway, A. M.
    WEAR, 2015, 332 : 1051 - 1058
  • [22] Understanding the influences of pre-corrosion on the erosion-corrosion performance of pipeline steel
    Xu, Yunze
    Liu, Liang
    Zhou, Qipiao
    Wang, Xiaona
    Huang, Yi
    WEAR, 2020, 442 (442-443)
  • [23] Optimal input design for identification in closed-loop
    Bányász, CS
    Keviczky, L
    ROBOTICS, AUTOMATION AND CONTROL AND MANUFACTURING: TRENDS, PRINCIPLES AND APPLICATIONS, 2002, 14 : 155 - 162
  • [24] DESIGN OF OPTIMAL CONTROLLER FOR CLOSED-LOOP PLANT
    AREFEV, BA
    FOKIN, AL
    AUTOMATION AND REMOTE CONTROL, 1977, 38 (11) : 1627 - 1632
  • [25] Closed-loop pole design for vibration suppression
    Papadopoulos, M
    Garcia, E
    JOURNAL OF GUIDANCE CONTROL AND DYNAMICS, 1997, 20 (02) : 333 - 337
  • [26] On the closed-loop design of flexible robotic links
    Zhou, PX
    Williams, MS
    Wang, FY
    INFORMATION INTELLIGENCE AND SYSTEMS, VOLS 1-4, 1996, : 1712 - 1717
  • [27] Design of closed-loop input shaping controllers
    Staehlin, U
    Singh, T
    PROCEEDINGS OF THE 2003 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2003, : 5167 - 5172
  • [28] Mechatronics design for a programmable closed-loop mechanism
    Zhang, WJ
    Chen, XB
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2001, 215 (03) : 365 - 375
  • [29] The design of closed-loop digital fluxgate sensor
    Ji, Qing-hua
    Jia, Meng
    MECHANICAL, MATERIALS AND MANUFACTURING ENGINEERING, PTS 1-3, 2011, 66-68 : 1012 - 1016
  • [30] Design and Implementation of a Closed-Loop Plant Factory
    Quan, Q.
    Zhang, X.
    Xue, X. Z.
    IFAC PAPERSONLINE, 2018, 51 (17): : 353 - 358