Numerical Study on Coupled Smoke Control Using Longitudinal Ventilation and Naturally Ventilated Shafts during Fires in a Road Tunnel

被引:2
|
作者
Yao, Yongzheng [1 ,2 ]
Wang, Yintong [1 ]
Chen, Liang [1 ,2 ]
Ren, Fei [2 ]
Shi, Congling [2 ]
机构
[1] China Univ Min & Technol Beijing, Sch Emergency Management & Safety Engn, Beijing 100083, Peoples R China
[2] China Acad Safety Sci & Technol, Beijing Key Lab Metro Fire & Passenger Transportat, Beijing 100012, Peoples R China
来源
FIRE-SWITZERLAND | 2023年 / 6卷 / 03期
基金
中国国家自然科学基金;
关键词
tunnel fire; natural ventilation; longitudinal ventilation; smoke control; CRITICAL VELOCITY; BACKLAYERING LENGTH; VERTICAL SHAFT; FLOW;
D O I
10.3390/fire6030126
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
Longitudinal ventilation and smoke extraction by shaft are common smoke control methods in road tunnel fires. Tunnels often adopt one of these methods in practical engineering. However, it may have a better effect to adopt the method of mixing the two smoke exhaust methods together, which has not been revealed in the previous literature. Hence, the coupled effects of longitudinal ventilation and natural ventilation with shafts on the smoke control in tunnel fires were studied in this work. Numerical simulation was carried out considering different longitudinal ventilation velocities (0-4 m/s) and 4 kinds of typical shaft arrangements (shaft lengths range of 3-12 m, shaft intervals range of 27-60 m). The smoke spread length and smoke exhaust efficiency were analyzed systematically. Results show that (1) with the increase in longitudinal ventilation velocity, the total smoke spread length firstly decreases (V < 1 m/s) and then keeps almost constant (1 m/s < V < 2 m/s), finally increasing significantly (V > 2 m/s). (2) The length of the dangerous area (over 60 degrees C) at human height is basically 0 for all cases (except for Scenario 4 of shaft arrangement) when the longitudinal ventilation velocity is less than 2 m/s. (3) The CO smoke flow rate through the shaft is relatively high when the longitudinal ventilation velocity is within the range of 1-2 m/s for 4 kinds of shaft arrangement scenarios. Factors such as smoke spread and smoke exhausted through the shaft are comprehensively considered to judge smoke exhaust performance. The following conclusions can be drawn: when the ventilation velocity ranges from 1-2 m/s, it has a positive impact on the smoke control in tunnel fires with natural ventilation with shafts. When the ventilation velocity exceeds 2 m/s, the total smoke spread length and the length of the danger area increase, and the smoke stratification becomes worse, which brings inconvenience to rescue work. The results can provide reference for the design of fire protection in tunnels.
引用
下载
收藏
页数:13
相关论文
共 50 条
  • [21] Numerical studies on the smoke control by water mist screens with transverse ventilation in tunnel fires
    Liang, Qiang
    Li, Yangfeng
    Li, Junmei
    Xu, Hui
    Li, Kaiyuan
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2017, 64 : 177 - 183
  • [22] Experimental study on temperature decay and smoke control in tunnel fires with combination of multi-point smoke exhaust and longitudinal ventilation
    Li, Jie
    Zeng, Yanhua
    Tao, Liangliang
    Liu, Zhenhan
    Li, Baojun
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 183
  • [23] Experimental study on collaborative longitudinal ventilation of smoke control for branched tunnel fires considering different branch angles
    Lei, Peng
    Chen, Changkun
    Jiao, Weibing
    Shi, Congling
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 136
  • [24] Numerical Study on Smoke Control in Urban Traffic Link Tunnel Fires
    Hua Gaoying
    Wang Wei
    Zhao Yaohua
    Li Lei
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL VII, PTS A AND B, 2008, 7 : 820 - 827
  • [25] Numerical study on the smoke extraction efficiency and the improvement through a smoke reservoir in the naturally ventilated tunnel with vertical shaft
    Xu, Zhisheng
    Xu, Weikun
    He, Lu
    Xie, En
    Wang, Tianxiong
    Tao, Haowen
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 103
  • [26] Driving force for preventing smoke backlayering in downhill tunnel fires using forced longitudinal ventilation
    Du, Tao
    Yang, Dong
    Ding, Yao
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2018, 79 : 76 - 82
  • [27] Numerical study on smoke temperature distribution in naturally ventilated inclined tunnels: Effects of tunnel width and tunnel slope
    Cong, Wei
    Nie, Shibin
    Li, Xin
    Peng, Wei
    Case Studies in Thermal Engineering, 2024, 62
  • [28] A study on road tunnel fires using Hazmat, with emphasis on critical ventilation velocity
    Palazzi, E
    Currò, F
    Fabiano, B
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2005, 83 (B5) : 443 - 451
  • [29] Effect of single-side centralized exhaust on smoke control and temperature distribution in longitudinal ventilation tunnel fires
    Tao, Liangliang
    Zeng, Yanhua
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2022, 119
  • [30] A coupled hybrid numerical study of tunnel longitudinal ventilation under fire conditions
    Alvarez-Coedo, Diego
    Ayala, Pablo
    Cantizano, Alexis
    Wegrzynski, Wojciech
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 36