Monitoring of toxic metals and metalloids in the urine of non-professional sportsmen using total reflection x-ray fluorescence

被引:2
|
作者
Jablan, Jasna [1 ]
Ortner Hadziabdic, Maja [2 ]
Domijan, Ana-Marija [3 ]
Inic, Suzana [1 ]
Stosnach, Hagen [4 ]
机构
[1] Univ Zagreb, Fac Pharm & Biochem, Dept Analyt Chem, Zagreb, Croatia
[2] Univ Zagreb, Fac Pharm & Biochem, Ctr Appl Pharm, Zagreb, Croatia
[3] Univ Zagreb, Fac Pharm & Biochem, Dept Pharmaceut Bot, Zagreb, Croatia
[4] Bruker Nano GmbH, Berlin, Germany
关键词
non-professional sportsmen; toxic metals; TXRF; urine samples; TRACE-ELEMENTS; PHYSICAL-ACTIVITY; PLASMA; SPECTROMETRY; SAMPLES; BLOOD; ALUMINUM; TRENDS;
D O I
10.1002/xrs.3415
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Exposure to toxic metals and metalloids is a significant public health concern and can seriously affect human health. The aim of this study was to establish the presence of toxic metals and metalloids in the urine of non-professional sportsmen who participated in a mountain ultramarathon using a benchtop total reflection x-ray fluorescence (TXRF) system. TXRF allows for easy and rapid sample preparation and is therefore a potential candidate for simple and cost-effective analysis. In this work, the TXRF-Mo system was used for multielement analysis of the urine samples of 21 non-professional athletes who ran a 53 km mountain ultra-marathon. Urine samples were collected at four time points, at the beginning of the race (pre-race samples), immediately, and 12 and 24 h post-race. Al, As, Ba, Ni, Pb, Rb, Sr, V, and Tl were detected in the collected urine samples. The accuracy and precision of the proposed methods were verified by the analysis of reference materials (Seronorm (TM) Trace Elements Urine Level 2). The TXRF results were in agreement with the reference values and no significant differences were observed at the 95% confidence level. The detection limits for the elements of interest were also reasonable considering their concentration ranges in real samples. Changes were observed over time with increasing average urinary metals and metalloids levels, but only two significant results, were an increase in As and Rb. The results indicate a high degree of inter-subject variability. The results obtained show that the content of toxic metals and metalloids increases in the urine samples collected after the race, which could confirm the statement that physical activity can increase the excretion of toxic metals and metalloids from the body. The simplicity of the TXRF method as well as its fast performance make it suitable for routine analysis.
引用
收藏
页码:531 / 539
页数:9
相关论文
共 50 条
  • [21] DETERMINATION OF METALS IN OIL USING TOTAL REFLECTION X-RAY-FLUORESCENCE SPECTROMETRY
    BILBREY, DB
    LELAND, DJ
    LEYDEN, DE
    WOBRAUSCHEK, P
    AIGINGER, H
    X-RAY SPECTROMETRY, 1987, 16 (04) : 161 - 165
  • [22] Determination of metals and their species in aquatic humic substances by using total-reflection X-ray fluorescence spectrometry
    Aster, B
    vonBohlen, A
    Burba, P
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (07) : 1009 - 1018
  • [23] Determination of metals and their species in aquatic humic substances by using total-reflection X-ray fluorescence spectrometry
    Inst for Spectrochemistry and, Applied Spectroscopy, Dortmund, Germany
    Spectrochim Acta Part B At Spectrosc, 7 (1009-1018):
  • [24] Preliminary experiment of total reflection x-ray fluorescence using two glancing x-ray beams excitation
    Tsuji, K
    Sato, T
    Wagatsuma, K
    Claes, M
    Van Grieken, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (03): : 1621 - 1623
  • [25] TOTAL-REFLECTION X-RAY-FLUORESCENCE ANALYSIS USING SPECIAL X-RAY SOURCES
    WOBRAUSCHEK, P
    KREGSAMER, P
    LADISICH, W
    RIEDER, R
    STRELI, C
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (02) : 143 - 151
  • [26] Total Reflection X-Ray Fluorescence at the Air Water Interface using XeRay
    Gong, Zhiliang
    Kerr, Daniel
    Hwang, Hyeondo L.
    Henderson, J. Michael
    Suwatthee, Tiffany
    Slaw, Benjamin R.
    Cao, Kathleen D.
    Lin, Binhua
    Bu, Wei
    Yee, Ka
    Lee, C.
    BIOPHYSICAL JOURNAL, 2017, 112 (03) : 175A - 175A
  • [27] QUANTITATIVE ANALYSIS OF LIQUID SAMPLES USING TOTAL REFLECTION X-RAY FLUORESCENCE
    Hashimoto, Hideki
    Iida, Yutaka
    Saisho, Hideo
    Nishioji, Hiroshi
    ANALYTICAL SCIENCES, 1991, 7 : 577 - 580
  • [28] Total-reflection x-ray fluorescence spectrometer using a rotating anode
    Chalmers Univ of Technology, Goteborg, Sweden
    Nucl Instrum Methods Phys Res Sect A, 3 (553-559):
  • [29] Quantification of gold nanoparticles in blood using total reflection X-ray fluorescence
    Mankovskii, Gabriella
    Pejovic-Milic, Ana
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2022, 194
  • [30] Biomonitoring of urban industrial pollution using total reflection X-ray fluorescence
    Schmeling, M.
    Gende, M.
    Tovar, A.
    X-RAY SPECTROMETRY, 2025, 54 (02) : 118 - 126