Temperature Fluctuation of a Closed-Cycle Helium Joule-Thomson Cryocooler with Two-Stage Precooling

被引:1
|
作者
Chen, Zhichao [1 ,2 ]
Cui, Xiaoyu [1 ]
Liu, Shaoshuai [2 ]
Wu, Yinong [2 ]
Jiang, Zhenhua [2 ]
Ding, Lei [1 ,2 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & power Engn, Shanghai 20093, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Technol & Phys, Shanghai 200083, Peoples R China
基金
中国博士后科学基金; 上海市自然科学基金; 中国国家自然科学基金;
关键词
temperature fluctuation; liquid helium temperature; Joule-Thomson cryocooler; precooling temperature; MECHANICAL COOLER;
D O I
10.1007/s11630-023-1819-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
For quantum communications, single-photon detection, millimeter wave detection and other space projects, all of them need to work at liquid helium temperatures to achieve excellent performance. The closed-cycle helium Joule-Thomson cryocooler (JTC) is currently one of the mainstream solutions to realize the liquid helium temperature. While realizing the liquid helium temperature, the detector has strict requirements on the temperature fluctuation of the JTC, because the thermal noise caused by the JTC temperature fluctuation will have a critical impact on the detection performance. The typical closed-cycle helium JTC is precooling by a two-stage precooler. When the operating parameters of the JTC compressor remain unchanged, the change of the precooler is the main factor that affects the temperature fluctuation of the JTC. To explore the influence mechanism of JTC temperature fluctuations, experimental and theoretical studies are carried out. Based on the real gas equation of state, the influence of various parameters on the evaporator temperature fluctuations is explained. Research results show that the increase in temperature of each stage will cause the temperature of the JTC to increase. Especially, the change of the secondary precooling temperature (T-pre2) has the most obvious influence on JTC temperature. Furthermore, the influence of the JT compressor's buffer tank volume V-b on temperature fluctuation is studied. By increasing the V-b, the JTC temperature fluctuation caused by the temperature change of the precooler can be effectively reduced.
引用
收藏
页码:1501 / 1511
页数:11
相关论文
共 50 条
  • [31] Experimental study on an open-cycle conical Hampson-type miniature Joule-Thomson cryocooler
    Pan, Zhicheng
    Li, Xiaoyong
    Wang, Ling
    Huang, Taihe
    Zhang, Xiaoqing
    Ye, Jianjun
    Chen, Jianye
    APPLIED THERMAL ENGINEERING, 2023, 230
  • [32] Prediction of two-phase pressure drop in heat exchanger for mixed refrigerant Joule-Thomson cryocooler
    Ardhapurkar, P. M.
    Atrey, M. D.
    ADVANCES IN CRYOGENIC ENGINEERING, 2015, 101
  • [33] Experimental investigation on temperature profile and pressure drop in two-phase heat exchanger for mixed refrigerant Joule-Thomson cryocooler
    Ardhapurkar, P. M.
    Sridharan, Arunkumar
    Atrey, M. D.
    APPLIED THERMAL ENGINEERING, 2014, 66 (1-2) : 94 - 103
  • [34] Hampson's type cryocoolers with distributed Joule-Thomson effect for mixed refrigerants closed cycle
    Maytal, Ben-Zion
    CRYOGENICS, 2014, 61 : 92 - 96
  • [35] Thermal shunt for quick cool-down of two-stage closed-cycle refrigerator
    Uhlig, K
    CRYOGENICS, 2002, 42 (01) : 67 - 69
  • [36] Numerical analysis of the two-phase heat transfer in the heat exchanger of a mixed refrigerant Joule-Thomson cryocooler
    Damle, R. M.
    Ardhapurkar, P. M.
    Atrey, M. D.
    CRYOGENICS, 2015, 72 : 103 - 110
  • [37] Thermodynamic analysis and optimization of 80K closed-cycle Joule-Thompson cryocooler with gas mixture
    Luo, EC
    Zhou, Y
    Gong, MQ
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 43 PTS A AND B, 1998, 43 : 1679 - 1683
  • [38] Operation of a high-TC SQUID gradiometer with a two-stage MEMS-based Joule-Thomson micro-cooler
    Kalabukhov, Alexey
    de Hoon, Erik-Jan
    Kuit, Kristiaan
    Lerou, Pieter-Paul P. P. M.
    Chukharkin, Maxim
    Schneiderman, Justin F.
    Sepehri, Sobhan
    Sanz-Velasco, Anke
    Jesorka, Aldo
    Winkler, Dag
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2016, 29 (09):
  • [39] Thermodynamic performance comparison of a two-stage cryocooler and cascade cryocoolers with thermal anchoring for precooling purpose
    Jeong, Sangkwon
    Jin, Lingxue
    CRYOGENICS, 2019, 99 : 32 - 38
  • [40] Experimental investigation of mixed-refrigerant Joule-Thomson cryocooler in 70K to 100K temperature range
    Luo, EC
    Gong, MQ
    Zhou, Y
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR 98, 1998, : 393 - 396