Performance Evaluation of Distributed Extended KDamper Devices for Seismic Protection of Mid-Rise Building Structures

被引:15
|
作者
Kapasakalis, K. [1 ,4 ]
Mantakas, A. [1 ]
Kalderon, M. [2 ]
Antoniou, M. [3 ]
Sapountzakis, E. J. [1 ]
机构
[1] Natl Tech Univ Athens, Inst Struct Anal & Antiseism Res, Sch Civil Engn, Athens, Greece
[2] Natl Tech Univ Athens, Sch Mech Engn, Dynam & Acoust Lab, Athens, Greece
[3] Swiss Fed Inst Technol, Inst Geotech Engn, Dept Civil Environm & Geomat Engn, Zurich, Switzerland
[4] Natl Tech Univ Athens, Inst Struct Anal & Antiseism Res, Sch Civil Engn, Zografou Campus, GR-15780 Athens, Greece
基金
欧盟地平线“2020”;
关键词
Negative stiffness; seismic protection; KDamper; multiple tuned mass dampers; vibration control mechanism; TUNED-MASS DAMPERS; OPTIMUM DESIGN; PARAMETERS; ABSORBER; VIBRATIONS; SYSTEM;
D O I
10.1080/13632469.2023.2226227
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study proposes a novel seismic protection strategy that applies and distributes extended KDamper devices (d-EKD) along the height of an existing mid-rise building structure. The performance of the d-EKD is assessed on a set of real earthquake records and is compared to a system with optimally distributed Tuned Mass Dampers (d-TMD). The proposed framework with the d-EKDs manages to outperform the d-TMDs, regardless the number of installed devices, further reducing the structure's dynamic responses by more than 15%, using 10 times lower total additional masses, rendering it a realistic and compelling alternative for passive seismic protection.
引用
收藏
页码:972 / 997
页数:26
相关论文
共 50 条
  • [11] Seismic performance of architectural glass in mid-rise curtain wall
    Behr, Richard A.
    Journal of Architectural Engineering, 1998, 4 (03) : 94 - 98
  • [12] Seismic performance assessment of mid-rise confined masonry buildings
    Espinosa-Cazarin, Eric Fernando
    Teran-Gilmore, Amador
    Tapia-Hernandez, Edgar
    BULLETIN OF EARTHQUAKE ENGINEERING, 2023, 21 (10) : 5017 - 5039
  • [13] Investigation on improvement of seismic performance of the mid-rise buildings with geosynthetics
    Edincliler, Ayse
    Sekman, Mustafa
    INSIGHTS AND INNOVATIONS IN STRUCTURAL ENGINEERING, MECHANICS AND COMPUTATION, 2016, : 354 - 357
  • [14] Evaluation of building code compliance in MexicoCity: mid-rise dwellings
    Reinoso, Eduardo
    Jaimes, Miguel A.
    Torres, Marco A.
    BUILDING RESEARCH AND INFORMATION, 2016, 44 (02): : 202 - 213
  • [15] Comparing the performance of substructure and direct methods to estimate the effect of SSI on seismic response of mid-rise structures
    Asli, Sahand Jabini
    Saffari, Hamed
    Zahedi, Mohammad Javad
    Saadatinezhad, Maryam
    INTERNATIONAL JOURNAL OF GEOTECHNICAL ENGINEERING, 2021, 15 (01) : 81 - 94
  • [16] Improved equivalent bracing model for seismic analysis of mid-rise CFS structures
    Wang, Xingxing
    Ye, Jihong
    Yu, Qiang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 136 : 256 - 264
  • [17] Seismic Isolation Layout Optimized of Mid-Rise Reinforced Concrete Building Frame Structure
    Liu, Shengkun
    Chen, Zhidong
    Liu, Yongdou
    BUILDINGS, 2024, 14 (07)
  • [18] A Proposal for Seismic Evaluation Index of Mid-rise Existing RC Buildings in Afghanistan
    Naqi, Ahmad
    Saito, Taiki
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE OF GLOBAL NETWORK FOR INNOVATIVE TECHNOLOGY AND AWAM INTERNATIONAL CONFERENCE IN CIVIL ENGINEERING (IGNITE-AICCE'17): SUSTAINABLE TECHNOLOGY AND PRACTICE FOR INFRASTRUCTURE AND COMMUNITY RESILIENCE, 2017, 1892
  • [19] Effect of nonlinear soil-structure interaction and lateral stiffness on seismic performance of mid-rise RC building
    Firoj, Mohd
    Bahuguna, Ashish
    Kanth, Aparna
    Agrahari, Ravindra
    JOURNAL OF BUILDING ENGINEERING, 2022, 59
  • [20] EVALUATION OF SEISMIC PERFORMANCE OF MID-RISE CONCRETE MOMENT FRAME BUILDINGS CONSIDERING THE EFFECT OF INFILLED FRAMES
    Khaki, Mohammad
    INTERNATIONAL JOURNAL OF ECOSYSTEMS AND ECOLOGY SCIENCE-IJEES, 2019, 9 (02): : 313 - 332