Microgrid Hybrid Solar/Wind/Diesel and Battery Energy Storage Power Generation System: Application to Koh Samui, Southern Thailand

被引:5
|
作者
Khamharnphol, Rawit [1 ]
Kamdar, Ismail [2 ]
Waewsak, Jompob [2 ]
Chaichan, Weerasak [3 ]
Khunpetch, Sakrapee [1 ]
Chiwamongkhonkarn, Somphol [2 ]
Kongruang, Chuleerat [4 ]
Gagnon, Yves [5 ]
机构
[1] Nakhon Si Thammarat Rajabhat Univ, Fac Ind Technol, Nakhon Si Thammarat, Thailand
[2] Thaksin Univ, Fac Sci, Res Ctr Energy & Environm, Div Phys, Phatthalung Campus, Phatthalung, Thailand
[3] Thaksin Univ, Fac Engn, Phatthalung Campus, Phatthalung, Thailand
[4] Walailak Univ, Sch Accountancy & Finance, Nakhon Si Thammarat, Thailand
[5] Univ Moncton, Edmundston, NB, Canada
关键词
Solar PV; Wind Turbine Generator; Optimization; Levelized Cost of Energy; Renewable Fraction; Battery Energy Storage System; TECHNOECONOMIC ANALYSIS; FEASIBILITY ANALYSIS; DESIGN; ELECTRIFICATION; OPTIMIZATION; COMMUNITIES; OPERATION; AREAS;
D O I
10.14710/ijred.2023.47761
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents the optimization of a 10 MW solar/wind/diesel power generation system with a battery energy storage system (BESS) for one feeder of the distribution system in Koh Samui, an island in southern Thailand. The main objectives are to maximize the deployment of renewable energy-based power generation and to minimize the levelized cost of energy (LCOE). A hybrid renewable energy-based power generation system, consisting of solar PV, wind turbine generators, diesel generator (DiG), bi-directional grid-tied charging inverter (CONV) and BESS, was simulated using HOMER Pro (R). This study accessed the database of the National Aeronautics and Space Administration (NASA) for the Surface meteorology and Solar Energy (SSE) for the global solar radiation and temperature, along with the Modern-Era Retrospective analysis for Research and Applications (MERRA-2) wind database. The simulations show that Scenario 1 (PV/Wind/DiG/BESS/CONV) and Scenario 3 (PV/DiG/BESS/CONV) are the optimal configurations regarding the economic indicators (i.e. minimum net present costs (NPC) of 438 M$ and LCOE of 0.20$/kWh) and the environmental indicators (i.e. lowest greenhouse gases (GHG) emission avoidances of 6,339 tonnes/year and highest renewable fraction (RF) of 89.4%). Furthermore, the sensitivity analysis illustrates that Scenario 3 offers the optimal system type with the largest annual energy production (AEP). Besides contributing to the body of knowledge of optimization methodologies for microgrid hybrid power systems, the outcome of this work will assist the regional energy practitioners and policy makers regarding optimal configurations of microgrid hybrid systems in the development of a Green Island concept for Koh Samui.
引用
收藏
页码:216 / 226
页数:11
相关论文
共 50 条
  • [41] Design and Development of Hybrid Wind and Solar Energy System for Power Generation
    Prashanth, B. N.
    Pramod, R.
    Kumar, G. B. Veeresh
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (05) : 11415 - 11422
  • [42] Energy Storage Optimization of Wind Solar Hybrid Power Generation System Based on Improved Grasshopper Algorithm
    Li Y.
    Lin Y.-L.
    Distributed Generation and Alternative Energy Journal, 2023, 38 (04): : 1055 - 1072
  • [43] A strategy development for optimal generating power of small wind-diesel-solar hybrid microgrid system
    Van Huong Dong
    Xuan Phuong Nguyen
    2020 6TH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING AND COMMUNICATION SYSTEMS (ICACCS), 2020, : 1329 - 1334
  • [44] A Method for Minimizing Energy Cost in a Microgrid With Hybrid Renewable Power Generation Using Controlled Battery Energy Storage
    Khalid, Muhammad
    Savkin, Audrey V.
    Agelidis, Vassilios G.
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 8596 - 8600
  • [45] Energy Management of an Autonomous Hybrid Wind-Photovoltaic Microgrid with Battery Storage
    Ely, Ware
    Doumbia, Mamadou Lamine
    Tahar, Tafticht
    Betoka, Simon Pierre
    Hamza, Hamid
    2023 12TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS, ICRERA, 2023, : 492 - 498
  • [46] Cost Minimization of Battery-Supercapacitor Hybrid Energy Storage for Hourly Dispatching Wind-Solar Hybrid Power System
    Roy, Pranoy
    He, Jiangbiao
    Liao, Yuan
    IEEE ACCESS, 2020, 8 (08): : 210099 - 210115
  • [47] Optimal Sizing and Analysis of Solar PV, Wind, and Energy Storage Hybrid System for Campus Microgrid
    Ahmad, Furkan
    Alam, Mohammad Saad
    SMART SCIENCE, 2018, 6 (02): : 150 - 157
  • [48] A Hybrid Wind-Solar-Storage Energy Generation System Configuration and Control
    Shen, Dan
    Izadian, Afshin
    Liao, Ping
    2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 436 - 442
  • [49] Capacity optimization of hybrid energy storage units in wind/solar generation system
    Zhou, Tianpei
    Sun, Wei
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2015, 36 (03): : 756 - 762
  • [50] Application of Fuzzy Wavelet Transform to Smooth Wind/PV Hybrid Power System Output with Battery Energy Storage System
    Li, Xiangjun
    Li, Yong
    Han, Xiaojuan
    Hui, Dong
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON SMART GRID AND CLEAN ENERGY TECHNOLOGIES (ICSGCE 2011), 2011, 12