Microgrid Hybrid Solar/Wind/Diesel and Battery Energy Storage Power Generation System: Application to Koh Samui, Southern Thailand

被引:5
|
作者
Khamharnphol, Rawit [1 ]
Kamdar, Ismail [2 ]
Waewsak, Jompob [2 ]
Chaichan, Weerasak [3 ]
Khunpetch, Sakrapee [1 ]
Chiwamongkhonkarn, Somphol [2 ]
Kongruang, Chuleerat [4 ]
Gagnon, Yves [5 ]
机构
[1] Nakhon Si Thammarat Rajabhat Univ, Fac Ind Technol, Nakhon Si Thammarat, Thailand
[2] Thaksin Univ, Fac Sci, Res Ctr Energy & Environm, Div Phys, Phatthalung Campus, Phatthalung, Thailand
[3] Thaksin Univ, Fac Engn, Phatthalung Campus, Phatthalung, Thailand
[4] Walailak Univ, Sch Accountancy & Finance, Nakhon Si Thammarat, Thailand
[5] Univ Moncton, Edmundston, NB, Canada
关键词
Solar PV; Wind Turbine Generator; Optimization; Levelized Cost of Energy; Renewable Fraction; Battery Energy Storage System; TECHNOECONOMIC ANALYSIS; FEASIBILITY ANALYSIS; DESIGN; ELECTRIFICATION; OPTIMIZATION; COMMUNITIES; OPERATION; AREAS;
D O I
10.14710/ijred.2023.47761
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents the optimization of a 10 MW solar/wind/diesel power generation system with a battery energy storage system (BESS) for one feeder of the distribution system in Koh Samui, an island in southern Thailand. The main objectives are to maximize the deployment of renewable energy-based power generation and to minimize the levelized cost of energy (LCOE). A hybrid renewable energy-based power generation system, consisting of solar PV, wind turbine generators, diesel generator (DiG), bi-directional grid-tied charging inverter (CONV) and BESS, was simulated using HOMER Pro (R). This study accessed the database of the National Aeronautics and Space Administration (NASA) for the Surface meteorology and Solar Energy (SSE) for the global solar radiation and temperature, along with the Modern-Era Retrospective analysis for Research and Applications (MERRA-2) wind database. The simulations show that Scenario 1 (PV/Wind/DiG/BESS/CONV) and Scenario 3 (PV/DiG/BESS/CONV) are the optimal configurations regarding the economic indicators (i.e. minimum net present costs (NPC) of 438 M$ and LCOE of 0.20$/kWh) and the environmental indicators (i.e. lowest greenhouse gases (GHG) emission avoidances of 6,339 tonnes/year and highest renewable fraction (RF) of 89.4%). Furthermore, the sensitivity analysis illustrates that Scenario 3 offers the optimal system type with the largest annual energy production (AEP). Besides contributing to the body of knowledge of optimization methodologies for microgrid hybrid power systems, the outcome of this work will assist the regional energy practitioners and policy makers regarding optimal configurations of microgrid hybrid systems in the development of a Green Island concept for Koh Samui.
引用
收藏
页码:216 / 226
页数:11
相关论文
共 50 条
  • [1] Optimization of stand-alone and grid-connected hybrid solar/wind/fuel cell power generation for green islands: Application to Koh Samui, southern Thailand
    Chaichan, Weerasak
    Waewsak, Jompob
    Nikhom, Ruamporn
    Kongruang, Chuleerat
    Chiwamongkhonkarn, Somphol
    Gagnon, Yves
    ENERGY REPORTS, 2022, 8 : 480 - 493
  • [2] Hybrid Solar Wind Diesel Power Generation System
    Al-enezi, Noor M.
    Abuarafah, Samahir H.
    2015 SAUDI ARABIA SMART GRID CONFERENCE (SASG), 2015,
  • [3] An Optimal Hybrid Supercapacitor and Battery Energy Storage System in Wind Power Application
    Nguyen, Cong-Long
    Lee, Hong-Hee
    IECON 2015 - 41ST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2015, : 3010 - 3015
  • [4] Design of wind-solar-diesel-battery hybrid power system
    Hu, Wenlei
    Yang, Runsheng
    Xie, Pu
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 1818 - 1821
  • [5] Optimal sizing of a hybrid microgrid system using solar, wind, diesel, and battery energy storage to alleviate energy poverty in a rural area of Biskra, Algeria
    Bacha, Badis
    Ghodbane, Hatem
    Dahmani, Habiba
    Betka, Abir
    Toumi, Abida
    Chouder, Aissa
    JOURNAL OF ENERGY STORAGE, 2024, 84
  • [6] Reverse power management in a wind diesel system with a battery energy storage
    Sebastian, R.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 44 (01) : 160 - 167
  • [7] Application of a battery energy storage for frequency regulation and peak shaving in a wind diesel power system
    Sebastian, Rafael
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (03) : 764 - 770
  • [8] Life cycle planning of battery energy storage system in off-grid wind-solar-diesel microgrid
    Zhang, Yuhan
    Wang, Jianxue
    Berizzi, Alberto
    Cao, Xiaoyu
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (20) : 4451 - 4461
  • [9] Optimization of Battery-Supercapacitor Hybrid Energy Storage Station in Wind/Solar Generation System
    Zhou, Tianpei
    Sun, Wei
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2014, 5 (02) : 408 - 415
  • [10] Optimized Sizing of Energy Management System for Off-Grid Hybrid Solar/Wind/Battery/Biogasifier/Diesel Microgrid System
    Jasim, Ali M.
    Jasim, Basil H.
    Baiceanu, Florin-Constantin
    Neagu, Bogdan-Constantin
    MATHEMATICS, 2023, 11 (05)