Comparison of serum tumor markers combined with dual-source CT in the diagnosis of lung cancer

被引:8
|
作者
Shan, Yuqing [1 ]
Yin, Xiangyuan [1 ]
Zhao, Na [1 ]
Wang, Jie [2 ]
Yang, Shouxiang [1 ]
机构
[1] Peoples Hosp Rizhao, Dept Imaging, Taian Rd 126, Rizhao 276800, Peoples R China
[2] Lanshan Peoples Hosp Rizhao, Dept Imaging, Rizhao, Peoples R China
关键词
Lung neoplasms; Biomarkers; tumor; Serology; Tomography; X-ray computed; CARCINOEMBRYONIC ANTIGEN CEA; INTERNATIONAL ASSOCIATION; BIOMARKER; CLASSIFICATION; EPIDEMIOLOGY; CYFRA21-1; PROPOSAL;
D O I
10.23736/S0026-4806.21.07124-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The purpose of this study is to explore the clinical value of serum tumor markers combined with dualsource CT scanning in the diagnosis of lung cancer. METHODS: One hundred-two patients with lung cancer (malignant tumor group), 50 patients with benign lesions (benign control group) and 50 healthy patients (normal control group) were selected as the research objects. The levels of serum carcinoembryonic antigen (CEA), cytokeratin 19 fragment antigen 21-1 (CYFRA21-1) and gastrin releasing peptide precursor 31-98 (Pro-GRP31-98) were detected using the electrochemiluminescence and enzyme-linked immunoassay in three groups of people. Simultaneously, Siemens' second-generation dual-source CT (Siemens AG, Munich, Germany) is used to scan the lungs of patients with lung cancer and benign lesions. Retrospective statistical analysis is utilized to explore the clinical value of serum tumor markers combined with dual-source CT examination in the diagnosis of lung cancer. RESULTS: The levels of serum CEA, CYFRA21-1 and Pro-GRP31-98 in lung cancer patients were significantly higher than those in the benign control group and normal control group, and the difference was statistically significant (P<0.01). There was no statistical difference between the benign control group and the normal control group (P>0.05). The levels of serum CEA, CYFRA21-1, Pro-GRP31-98 had no significant correlation with the age, sex, and tumor site of lung cancer patients (P>0.05). However, the levels of serum CEA, CYFRA21-1, Pro-GRP31-98 have an obvious correlation with tumor size, clinical stage, histological type, combined pleural effusion, recurrence and metastasis after treatment (P<0.05). CT scans of 102 lung cancer patients showed 35 cases of central type, 67 cases of peripheral type, 71 cases with tumor diameter >5cm, 31 cases of <= 5cm and 67 cases of lymph node metastasis. The sensitivities of CEA, CYFRA21-1, Pro-GRP31-98, and dual-source CT in the diagnosis of lung cancer were 64.70%, 60.11%, 56.86% and 77.45%, and the accuracy was 75.00%, 72.37%, 69.74% and 82.89%, respectively. Compared with a single examination, the sensitivity and accuracy of combined examination for the diagnosis of lung cancer were significantly improved, which were 95.10% and 92.76%, respectively. CONCLUSIONS: Joint examinations can effectively improve the rate of lung cancer diagnosis.
引用
收藏
页码:795 / 801
页数:7
相关论文
共 50 条
  • [21] Clinical application of serum tumor abnormal protein combined with tumor markers in lung cancer patients
    Tong, Hongfang
    Dan, Binzhi
    Dai, Heping
    Zhu, Mei
    FUTURE ONCOLOGY, 2022, 18 (11) : 1357 - 1369
  • [22] Feasibility research of combined assay with serum tumor marker and low dose CT on the early diagnosis of lung cancer
    Jiang, Haitao
    Kuang, Pingding
    Liu, Lulu
    Shao, Guoliang
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (13): : 5768 - 5771
  • [23] Initial experience of dual-energy lung perfusion CT using a dual-source CT system in children
    Goo, Hyun Woo
    PEDIATRIC RADIOLOGY, 2010, 40 (09) : 1536 - 1544
  • [24] Initial experience of dual-energy lung perfusion CT using a dual-source CT system in children
    Hyun Woo Goo
    Pediatric Radiology, 2010, 40 : 1536 - 1544
  • [25] The diagnostic evaluation of dual-source CT (DSCT) in the diagnosis of coronary artery stenoses
    Lei, Ziqiao
    Gu, Jin
    Fu, Qing
    Shi, Heshui
    Xu, Haibo
    Han, Ping
    Yu, Jianming
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2013, 29 (01) : 107 - 111
  • [26] PET, CT and tumor markers in lung cancer
    Kley, K.
    Oehr, P.
    TUMOR BIOLOGY, 2007, 28 : 29 - 29
  • [27] The role of serum tumor markers in lung cancer
    Quoix, E
    NEW ADVANCES IN THORACIC ONCOLOGY: FROM SCIENTIFIC EVIDENCE TO OPTIMAL MANAGEMENT, 2005, 350 : 11 - 16
  • [28] Quantitative assessment of motion effects in dual-source dual-energy CT and dual-source photon-counting detector CT
    Ahmed, Zaki
    Rajendran, Kishore
    Gong, Hao
    McCollough, Cynthia
    Leng, Shuai
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [29] Application of Dual-Source CT Using Iterative Reconstruction Technology Combined with CT-FFR Parameters in the Diagnosis of Coronary Heart Disease
    Wu, Cuicui
    Wang, Ziyue
    Shi, Hongxiu
    Ding, Yan
    Zhou, Jian
    Yan, Wenfu
    Wang, Li
    DISCOVERY MEDICINE, 2023, 35 (178) : 897 - 909
  • [30] Thoracic applications of dual-source CT technology
    Boroto, Kahimano
    Remy-Jardin, Martine
    Flohr, Thomas
    Faivre, Jean-Baptiste
    Pansini, Vittorio
    Tacelli, Nunzia
    Schmidt, Bernhard
    Gorgos, Andrei
    Remy, Jacques
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : 375 - 384