Comparison of serum tumor markers combined with dual-source CT in the diagnosis of lung cancer

被引:8
|
作者
Shan, Yuqing [1 ]
Yin, Xiangyuan [1 ]
Zhao, Na [1 ]
Wang, Jie [2 ]
Yang, Shouxiang [1 ]
机构
[1] Peoples Hosp Rizhao, Dept Imaging, Taian Rd 126, Rizhao 276800, Peoples R China
[2] Lanshan Peoples Hosp Rizhao, Dept Imaging, Rizhao, Peoples R China
关键词
Lung neoplasms; Biomarkers; tumor; Serology; Tomography; X-ray computed; CARCINOEMBRYONIC ANTIGEN CEA; INTERNATIONAL ASSOCIATION; BIOMARKER; CLASSIFICATION; EPIDEMIOLOGY; CYFRA21-1; PROPOSAL;
D O I
10.23736/S0026-4806.21.07124-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The purpose of this study is to explore the clinical value of serum tumor markers combined with dualsource CT scanning in the diagnosis of lung cancer. METHODS: One hundred-two patients with lung cancer (malignant tumor group), 50 patients with benign lesions (benign control group) and 50 healthy patients (normal control group) were selected as the research objects. The levels of serum carcinoembryonic antigen (CEA), cytokeratin 19 fragment antigen 21-1 (CYFRA21-1) and gastrin releasing peptide precursor 31-98 (Pro-GRP31-98) were detected using the electrochemiluminescence and enzyme-linked immunoassay in three groups of people. Simultaneously, Siemens' second-generation dual-source CT (Siemens AG, Munich, Germany) is used to scan the lungs of patients with lung cancer and benign lesions. Retrospective statistical analysis is utilized to explore the clinical value of serum tumor markers combined with dual-source CT examination in the diagnosis of lung cancer. RESULTS: The levels of serum CEA, CYFRA21-1 and Pro-GRP31-98 in lung cancer patients were significantly higher than those in the benign control group and normal control group, and the difference was statistically significant (P<0.01). There was no statistical difference between the benign control group and the normal control group (P>0.05). The levels of serum CEA, CYFRA21-1, Pro-GRP31-98 had no significant correlation with the age, sex, and tumor site of lung cancer patients (P>0.05). However, the levels of serum CEA, CYFRA21-1, Pro-GRP31-98 have an obvious correlation with tumor size, clinical stage, histological type, combined pleural effusion, recurrence and metastasis after treatment (P<0.05). CT scans of 102 lung cancer patients showed 35 cases of central type, 67 cases of peripheral type, 71 cases with tumor diameter >5cm, 31 cases of <= 5cm and 67 cases of lymph node metastasis. The sensitivities of CEA, CYFRA21-1, Pro-GRP31-98, and dual-source CT in the diagnosis of lung cancer were 64.70%, 60.11%, 56.86% and 77.45%, and the accuracy was 75.00%, 72.37%, 69.74% and 82.89%, respectively. Compared with a single examination, the sensitivity and accuracy of combined examination for the diagnosis of lung cancer were significantly improved, which were 95.10% and 92.76%, respectively. CONCLUSIONS: Joint examinations can effectively improve the rate of lung cancer diagnosis.
引用
收藏
页码:795 / 801
页数:7
相关论文
共 50 条
  • [1] Value of dual-source CT dual-energy parameters combined with serum detection of VEGF and CEA in the diagnosis of early lung cancer
    Ren, Liliang
    Yang, Yulong
    BIOTECHNOLOGY AND GENETIC ENGINEERING REVIEWS, 2023, 39 (02) : 1000 - 1011
  • [2] Dual-source CT in chest pain diagnosis
    Johnson, T. R. C.
    Nikolaou, K.
    Fink, C.
    Becker, A.
    Knez, A.
    Rist, C.
    Reiser, M. F.
    Becker, C. R.
    RADIOLOGE, 2007, 47 (04): : 301 - 309
  • [3] Clinical application of dual-source CT in the diagnosis of ALCAPA
    程召平
    ChinaMedicalAbstracts(InternalMedicine), 2014, 31 (01) : 3 - 3
  • [4] The Serum Tumor Markers in Combination for Clinical Diagnosis of Lung Cancer
    Wu, Heming
    Wang, Qiuming
    Liu, Qinghua
    Zhang, Qunji
    Huang, Qingyan
    Yu, Zhikang
    CLINICAL LABORATORY, 2020, 66 (03) : 269 - 276
  • [5] Application of dual-source CT perfusion imaging and MRI for the diagnosis of primary liver cancer
    Zhang, Dongwen
    Xu, Aixia
    ONCOLOGY LETTERS, 2017, 14 (05) : 5753 - 5758
  • [6] PET-CT Combined With Tumor Markers on Peripheral Lung Cancer
    An, Lin
    Liu, Yanli
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2020, 126 : 55 - 55
  • [7] Image quality of lung perfusion with photon-counting-detector CT: comparison with dual-source, dual-energy CT
    Remy-Jardin, Martine
    Guiffault, Lucas
    Oufriche, Idir
    Duhamel, Alain
    Flohr, Thomas
    Schmidt, Bernhard
    Remy, Jacques
    EUROPEAN RADIOLOGY, 2024, 34 (12) : 7831 - 7844
  • [8] Utility of a Combined Panel of Six Serum Tumor Markers for Lung Cancer
    Molina, Rafael
    Marrades, Ramon
    Reguart, Noemi
    Agusti, Alvar
    JOURNAL OF THORACIC ONCOLOGY, 2016, 11 (10) : S181 - S182
  • [9] Assessment of Individual and Combined of Five Serum Tumor Markers for Lung Cancer
    Li, Y.
    Xu, H.
    Ye, J.
    Chen, C.
    JOURNAL OF THORACIC ONCOLOGY, 2018, 13 (10) : S690 - S690
  • [10] Assessment of a Combined Panel of Six Serum Tumor Markers for Lung Cancer
    Molina, Rafael
    Marrades, Ramon M.
    Maria Auge, Josep
    Escudero, Jose M.
    Vinolas, Nuria
    Reguart, Noemi
    Ramirez, Jose
    Filella, Xavier
    Molins, Laureano
    Agusti, Alvar
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193 (04) : 427 - 437