Removal of harmful oxyanions from contaminated water by Donnan dialysis

被引:3
|
作者
Akula, Vishnu V. [1 ]
Philip, Ligy [1 ]
机构
[1] IIT Madras, Dept Civil Engn, Environm Engn Div, Chennai 600036, India
关键词
Oxyanion; Donnan dialysis; Anion exchange membranes; FAD PET 75; FAS PET 75; Predictive kinetic modelling; NITRATE REMOVAL; ANION-EXCHANGE; WASTE-WATER; PERCHLORATE; REGENERATION; GROUNDWATER; REDUCTION; MEMBRANES; RESIN;
D O I
10.1016/j.jwpe.2023.104085
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The removal of oxyanions like nitrate, sulphate, phosphate, chromate and perchlorate was investigated in single, binary and multi-component feed systems using Donnan dialysis across two homogeneous anion exchange membranes, FAD PET 75 and FAS PET 75. The ion exchange isotherms were established for oxyanion - chloride binary systems with both anion exchange membranes. The effect of initial concentration, recirculation flow rate, and receiver salt concentration was examined with FAD PET 75. The overall kinetic coefficient was calculated from the flux equation and was used to compare the transport kinetics of different oxyanions. The kinetics of oxyanions removal followed the order of nitrate > perchlorate > chromate > sulphate > phosphate, which can be attributed to the hydrated radius and structure of the oxyanions. The presence of co-existing oxyanions did not show a significant effect on the removal of nitrate, perchlorate, and chromate while sulphate and phosphate were influenced by their presence. Based on the present study, FAD PET 75 was able to remove all the target oxyanions effectively whereas FAS PET 75 was ineffective in the removal of sulphate and phosphate because of the higher cross linkage of the matrix which was evident with its lower water content.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] ANION REMOVAL FROM WATER BY DONNAN DIALYSIS
    WALLACE, CJ
    REMBAUM, A
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1977, 174 (SEP): : 8 - 8
  • [2] Studies with spiral wound Donnan dialysis contactor for nitrate removal from contaminated water
    Verma, Akshaya Kumar
    Akodwaa-Boadi, Kofi
    Ronen, Zeev
    Oren, Yoram
    Gilron, Jack
    JOURNAL OF WATER PROCESS ENGINEERING, 2023, 54
  • [3] Bromide Ion Removal from Water Solutions by Donnan Dialysis
    Lakomska, Sylwia
    Wisniewski, Jacek A.
    OCHRONA SRODOWISKA, 2012, 34 (01): : 33 - 39
  • [4] The removal of chromium ions from water in Donnan dialysis process
    Wisniewski, Jacek A.
    Szerzyna, Slawomir
    DESALINATION AND WATER TREATMENT, 2018, 128 : 125 - 132
  • [5] Removal of troublesome anions from water by means of Donnan dialysis
    Wisniewski, J
    Rózanska, A
    Winnicki, T
    DESALINATION, 2005, 182 (1-3) : 339 - 346
  • [6] Donnan dialysis for hardness removal from water before electrodialytic desalination
    Wisniewski, Jacek
    Rozanska, Agnieszka
    DESALINATION, 2007, 212 (1-3) : 251 - 260
  • [7] Nitrate removal from natural water by coupling adsorption and Donnan dialysis
    Turki, Thouraya
    Ben Amor, Mohamed
    WATER SCIENCE AND TECHNOLOGY-WATER SUPPLY, 2017, 17 (03): : 771 - 779
  • [8] Fluoride removal from waters by Donnan dialysis
    Hichour, M
    Persin, F
    Sandeaux, J
    Gavach, C
    SEPARATION AND PURIFICATION TECHNOLOGY, 2000, 18 (01) : 1 - 11
  • [9] Removal of nitrate from groundwater by Donnan dialysis
    Breytus, Anna
    Hasson, David
    Semiat, Raphael
    Shemer, Hilla
    JOURNAL OF WATER PROCESS ENGINEERING, 2020, 34
  • [10] Fluoride removal from waters by Donnan dialysis
    Lab. Mat. et Procedes Membranaires, UMR 5635, CNRS, 1919 Rte. M., Montpellier, France
    Sep. Purif. Technol., 1 (1-11):