A novel non-contact heart rate measurement method based on EEMD combined with FastICA

被引:7
|
作者
Shi, Yingli [1 ,2 ]
Qiu, Jian [1 ,2 ]
Peng, Li [1 ,2 ]
Han, Peng [1 ,2 ]
Luo, Kaiqing [1 ,2 ]
Liu, Dongmei [1 ,2 ]
机构
[1] South China Normal Univ, Sch Phys & Telecommun Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] South China Normal Univ, Qingyuan Inst Sci & Technol Innovat, Qingyuan 511517, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
imaging photoplethysmography (IPPG); modified EEMD; modified FastICA; heart rate (HR); multi-region ROI; EMPIRICAL MODE DECOMPOSITION; IMAGE SENSOR; ROBUST;
D O I
10.1088/1361-6579/accefd
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. The imaging photoplethysmography (IPPG), which is applied to heart rate measurement, is susceptible to interference caused by illumination variations during photography. To improve the accuracy, robustness, and real-time performance of IPPG, a new method combined with modified ensemble empirical mode decomposition (EEMD) and fast independent component analysis (FastICA) was proposed. Approach. On the modified EEMD, to reduce the error caused by the residual white noise of the algorithm, it was characterized by recurrently updating zero-mean white noise for ensemble averaging based on the standard deviation of the input signal. On the modified FastICA, its constructed nonlinear function was superseded by Huber's approximation function to improve the robustness and running speed. Main results. Comparison experiments were conducted between the MAHNOB-HCI database and own collected data. In the hybrid natural light and computer screen light scenario, the mean absolute error (MAE) of heart rate amounted to 0.93 beats per minute and the correlation coefficient r
引用
收藏
页数:15
相关论文
共 50 条
  • [21] A Comparative Study of Video Signals for Non-contact Heart Rate Measurement
    Lueangwattana, Chanya
    Kondo, Toshiaki
    Haneishi, Hideaki
    2015 12TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2015,
  • [22] A non-contact ECG measurement system for pervasive heart rate detection
    Zhu, Da-Huan
    Wang, Lei
    Zhang, Yuan-Ting
    2008 INTERNATIONAL SPECIAL TOPIC CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, VOLS 1 AND 2, 2008, : 551 - 552
  • [23] Non-contact measurement of mental stress via heart rate variability
    Chen, Fei
    Kong, Lingqin
    Zhao, Yuejin
    Dong, Liquan
    Liu, Ming
    Hui, Mei
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XLIII, 2020, 11510
  • [24] Non-Contact Heart Rate Measurement Using Ghost Imaging System
    Yu, Jianming
    He, Yuchen
    Li, Bin
    Chen, Hui
    Zheng, Huaibin
    Liu, Jianbin
    Zhou, Lifan
    Niu, Yi
    Wu, Haodong
    Xu, Zhuo
    JOURNAL OF BIOPHOTONICS, 2025, 18 (04)
  • [25] Non-Contact Measurement Method Research Based on HoloLens
    Huang Jing
    Yang Boxiong
    Chen Jiajie
    2017 INTERNATIONAL CONFERENCE ON VIRTUAL REALITY AND VISUALIZATION (ICVRV 2017), 2017, : 267 - 271
  • [26] Non-Contact Heart Rate Estimation From Photoplethysmography Using EEMD and Convolution-Transformer Network
    Liu, Kehong
    Wu, Shuo
    Li, Tianhuan
    Gou, Shuiping
    Wang, Xinlin
    Guo, Zhang
    2024 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND VIRTUAL ENVIRONMENTS FOR MEASUREMENT SYSTEMS AND APPLICATIONS, CIVEMSA 2024, 2024,
  • [27] A non-contact method based on multiple signal classification algorithm to reduce the measurement time for accurately heart rate detection
    Bechet, P.
    Mitran, R.
    Munteanu, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (08):
  • [28] The Evolution of Heart Beat Rate Measurement Techniques From Contact Based Photoplethysmography to Non-Contact Based Photoplethysmography Imaging
    Khong, Wei Leong
    Mariappan, Muralindran
    2019 4TH IEEE INTERNATIONAL CIRCUITS AND SYSTEMS SYMPOSIUM (ICSYS), 2019,
  • [29] Non-contact Heart Rate Measurements Based on Skin Detection
    Zhao Ting
    Zhou Zuofeng
    Chen Pengyong
    Cao Jianzhong
    Yang Hongtao
    TENTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2018), 2018, 10806
  • [30] Non-contact heart rate measurement from face video based on group sparse representation
    Ou, Weihua
    Chen, Longbao
    Xiong, Jiahao
    Han, Jie
    Zeng, Wu
    Gou, Jianping
    DIGITAL SIGNAL PROCESSING, 2024, 144