Development of a Reference Device for the Calibration of Optical One-Shot Time-Interval Measurements

被引:0
|
作者
Kuhinek, Dalibor [1 ]
Bratko, Tomislav [1 ]
Vukosic, Hrvoje [1 ]
Gavranic, Ivica [2 ]
机构
[1] Univ Zagreb, Fac Min Geol & Petr Engn, Pierottijeva 6, Zagreb 10002, Croatia
[2] INEL MONTAZA Doo, Dane Duica 3, Zagreb 10000, Croatia
关键词
velocity of detonation measurement; electronic detonation speedometer; precision time delay; interval generation;
D O I
10.3390/electronics12020439
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents the development of a device that creates two or more light pulses with a precision time delay in a range from microseconds to several seconds and for the purpose of the calibration of velocity of detonation (VOD) measurement instruments. The device was assembled, programmed, and tested for functionality. Measurements were conducted using a reference counter. First, a precision OCXO (oven-controlled crystal oscillator) was used as a clock source. For verification of programmed subroutines, a counter oscillator output port was used as a source of clock signal for the microcontroller. This enabled the cancellation of possible oscillator errors. The signal had to be converted from an AC sine signal to a signal with positive values only using a clamper circuit. By the proposed solution, a calculable standard of time delay between two light pulses was achieved. According to the obtained results, this device can be used to calibrate field measurement devices for VOD measurements in explosives or some other use where the measurement device records the time interval between multiple light pulses. This enables more confidence in measurement results, faster recognition of instrument drift and increases the quality of measurement.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Optical Metagrating for One-Shot Polarization Measurements
    Lung, Shaun
    Pedersen, Nicolas R. H.
    Wang, Kai
    Kamali, Khosro Zangeneh
    Setzpfandt, Frank
    Sukhorukov, Andrey A.
    SPIE MICRO + NANO MATERIALS, DEVICES, AND APPLICATIONS 2019, 2019, 11201
  • [2] A method of serial data jitter analysis using one-shot time interval measurements
    Wilstrup, J
    INTERNATIONAL TEST CONFERENCE 1998, PROCEEDINGS, 1998, : 819 - 823
  • [3] PICOSECOND TIME-INTERVAL MEASUREMENTS
    RETTIG, JB
    DOBOS, L
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1995, 44 (02) : 284 - 287
  • [4] TIME-INTERVAL OPTIMIZATION IN ACTIVATION MEASUREMENTS
    ANTONOV, VA
    SOVIET ATOMIC ENERGY, 1988, 65 (06): : 987 - 997
  • [5] Facilitated vascular anastomoses: The one-shot device
    Nataf, P
    Hinchliffe, P
    Manzo, S
    Simpson, J
    Kirsch, WM
    Zhu, YH
    Anton, T
    ANNALS OF THORACIC SURGERY, 1998, 66 (03): : 1041 - 1044
  • [6] COMPENSATION FOR INCREASING ACCURACY OF TIME-INTERVAL MEASUREMENTS
    MAISYUKOV, VD
    FEDORCHENKO, SN
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1967, (06): : 1310 - +
  • [7] Compressive imaging via one-shot measurements
    Jalali, Shirin
    Yuan, Xin
    2018 IEEE INTERNATIONAL SYMPOSIUM ON INFORMATION THEORY (ISIT), 2018, : 416 - 420
  • [8] Gamma lifetimes and one-shot device testing analysis
    Balakrishnan, N.
    Ling, M. H.
    RELIABILITY ENGINEERING & SYSTEM SAFETY, 2014, 126 : 54 - 64
  • [9] Technology of Time-interval Measurement in Time and Frequency Remote Calibration System
    He, Tao
    Zhang, Huijun
    Zhao, Zhixiong
    Li, Xiaohui
    EIGHTH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2013, 8759
  • [10] REVIEW OF SUB-NANOSECOND TIME-INTERVAL MEASUREMENTS
    PORAT, DI
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1973, NS20 (05) : 36 - 51