Quantifying error introduced by iterative closest point image registration

被引:2
|
作者
Sun, Ningjia [1 ]
Bull, Thomas [2 ]
Austin, Rupert [1 ]
Bartlett, David [1 ]
O'Toole, Saoirse [1 ]
机构
[1] Kings Coll London, Guys Hosp, Fac Dent Oral & Craniofacial Sci, Ctr Clin Oral & Translat Sci, Floor 17,Tower Wing, London SE1 9RT, England
[2] Univ Southampton, Mech Engn Dept, 6 Univ Rd, Southampton SO17 1HE, England
关键词
Dental informatics/bioinformatics; Diagnostic systems; Dimensional change; Imaging; Oral diagnosis; Surface metrology software; TOOTH WEAR; SUBTRACTION; THRESHOLD;
D O I
10.1016/j.jdent.2024.104863
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this paper was to quantify the analysis error introduced by iterative closest point (ICP) image registration. We also investigated whether a subsequent subtraction process can reduce process error. Methods: We tested metrology and two 3D inspection software using calibration standards at 0.39 mu m, and 2.64 mu m and mathematically perfect defects (softgauges) at 2 and 20 mu m, on free form surfaces of increasing complexity and area, both with and without registration. Errors were calculated in percentage relative to the size of the defect being measured. Data were analysed in GraphPad Prism 9, normal and two-way ANOVA with posthoc Tukey's was applied. Significance was inferred at p < 0.05. Results: Using ICP registration introduced errors from 0 % to 15.63 % of the defect size depending on the surface complexity and size of the defect. Significant differences were observed in analysis measurements between metrology and 3D inspection software and within different 3D inspection software, however, one did not show clear superiority over another. Even in the absence of registration, defects at 0.39 mu m, and 2.64 mu m produced substantial measurement error (13.39-77.50 % of defect size) when using 3D inspection software. Adding an additional data subtraction process reduced registration error to negligible levels (<1 % independent of surface complexity or area). Conclusions: Commercial 3D inspection software introduces error during direct measurements below 3 mu m. When using an ICP registration, errors over 15 % of the defect size can be introduced regardless of the accuracy of adjacent registration surfaces. Analysis output between software are not consistently repeatable or comparable and do not utilise ISO standards. Subtracting the datasets and analysing the residual difference reduced error to negligible levels. Clinical significance: This paper quantifies the significant errors and inconsistencies introduced during the registration process even when 3D datasets are true and precise. This may impact on research diagnostics and clinical performance. An additional data processing step of scan subtraction can reduce this error but increases computational complexity.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Iterative Closest Point via MultiKernel Correntropy for Point Cloud Fine Registration
    Yi, Hao
    Hu, Limei
    Chen, Feng
    Ren, Xiaoping
    Duan, Shukai
    IEEE SIGNAL PROCESSING LETTERS, 2025, 32 : 766 - 770
  • [22] The Improvement of Iterative Closest Point with Edges of Projected Image
    Wang C.
    Virtual Reality and Intelligent Hardware, 2023, 5 (03): : 279 - 291
  • [23] Adaptive hill climbing and iterative closest point algorithm for multisensor image registration with partial Hausdorff distance
    Yang, XJ
    Sheng, YL
    Guan, WG
    Valin, P
    Sévigny, L
    SENSOR FUSION: ARCHITECTURES, ALGORITHMS, AND APPLICATIONS IV, 2000, 4051 : 99 - 109
  • [24] Improvement of iterative closest point with edges of projected image
    Chen WANG
    虚拟现实与智能硬件(中英文), 2023, 5 (03) : 279 - 291
  • [25] Image-based registration for a neurosurgical robot: comparison using iterative closest point and coherent point drift algorithms
    Cutter, Jennifer R.
    Styles, Iain B.
    Leonardis, Ales
    Dehghani, Hamid
    20TH CONFERENCE ON MEDICAL IMAGE UNDERSTANDING AND ANALYSIS (MIUA 2016), 2016, 90 : 28 - 34
  • [27] Robust generalized total least squares iterative closest point registration
    Estépar, RSJ
    Brun, A
    Westin, CF
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2004, PT 1, PROCEEDINGS, 2004, 3216 : 234 - 241
  • [28] The Iterative Closest Point Registration Algorithm Based on the Normal Distribution Transformation
    Shi, Xiuying
    Peng, Jianjun
    Li, Jiping
    Yan, Pitao
    Gong, Hangyu
    2018 INTERNATIONAL CONFERENCE ON IDENTIFICATION, INFORMATION AND KNOWLEDGE IN THE INTERNET OF THINGS, 2019, 147 : 181 - 190
  • [29] A bounded iterative closest point method for minimally invasive registration of the femur
    Rodriguez y Baena, Ferdinando
    Hawke, Trevor
    Jakopec, Matjaz
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (10) : 1135 - 1144
  • [30] Robust Scale Iterative Closest Point Algorithm Based on Correntropy for Point Set Registration
    Chen, Hongchen
    Wu, Zongze
    Du, Shaoyi
    Zhou, Nan
    Sun, Jing
    2016 AUSTRALIAN CONTROL CONFERENCE (AUCC), 2016, : 238 - 242