Prospective Comparison Between Manual and Computer-Assisted (FOX) Cochlear Implant Fitting in Newly Implanted Patients

被引:4
|
作者
Wathour, Justine [1 ]
Govaerts, Paul J. [2 ,3 ]
Derue, Lucie [1 ]
Vanderbemden, Suzanne [1 ]
Huaux, Helene [1 ]
Lacroix, Emilie [4 ,5 ]
Deggouj, Naima [1 ]
机构
[1] Clin Univ St Luc, Brussels, Belgium
[2] Eargroup, Antwerp, Belgium
[3] Univ Antwerp, Fac Med & Hlth Sci, Translat Neurosci Otorhinolaryngol & Head & Neck S, Antwerp, Belgium
[4] Royal Mil Acad, LIFE Dept, VIPER Res Unit, Brussels, Belgium
[5] Catholic Univ Louvain, Inst Res Psychol Sci IPSY, Louvain La Neuve, Belgium
来源
EAR AND HEARING | 2023年 / 44卷 / 03期
关键词
Artificial intelligence; Cochlear implant; Newly users; Programming; NEURAL RESPONSE TELEMETRY; PROCESSOR;
D O I
10.1097/AUD.0000000000001314
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective: A prospective, longitudinal, randomized controlled trial with an original crossover design for 1 year was conducted to compare manual fitting to artificial intelligence-based fitting in newly implanted patients. Design: Twenty-four patients who received their first cochlear implant (CI) were randomly assigned to the manual or Fitting to Outcome eXpert (FOX) arm; they followed the corresponding fitting procedures for 1 year. After 1 year, each patient was switched to another arm. The number of fittings, auditory outcomes (pure-tone thresholds, loudness scaling curves, spectral discrimination scores, bisyllabic word recognition in quiet and noise, and speech tracking), fitting session questionnaire, and CI parameters (T level, C level, Threshold Sound Pressure Level (T-SPL), Comfortable Sound Pressure Level (C-SPL), and loudness growth value) were compared between the two groups. Differences between the two groups were analyzed using the Mann-Whitney test, and Holm corrections were applied for multiple statistical tests. At the end of the crossover session, patients were offered the choice to continue with their old or new map. Results: As early as 3 mo postactivation, the FOX group showed less variability and significantly better speech intelligibility in quiet conditions at 40 and 55 dB SPL and noise (p < 0.05) with median phoneme scores of 50%, 70%, and 50% at 55, 70, and 85 dB SPL compared with 45%, 50%, and 40%, respectively. This group showed better results at 12 mo postactivation (p < 0.05). In the manual group, 100% of the patients decided to keep the new FOX map, and 82% performed better with the FOX map. In the FOX group, 63% of the patients decided to keep the manual map, although the measurable outcome had not improved. In this group, participants reported to prefer the manual map because it felt more comfortable, even if the FOX map gave better measured outcome. Conclusion: Although the study size remains relatively small, the AI-FOX approach was equivalent to or even outperformed the manual approach in hearing performance, comfort, and resources. Furthermore, FOX is a tool capable of continuous improvement by comparing its predictions with observed results and is continuously learning from clinicians' practice, which is why this technology promises major advances in the future.
引用
收藏
页码:494 / 505
页数:12
相关论文
共 50 条
  • [41] Comparison Between Simulated and Actual Unilateral Hearing in Sequentially Implanted Cochlear Implant Users, a Cohort Study
    van Zon, Alice
    Smulders, Yvette E.
    Kraaijenga, Veronique J. C.
    van Zanten, Gijsbert A.
    Stokroos, Robert J.
    Stegeman, Inge
    FRONTIERS IN SURGERY, 2019, 6
  • [42] Interrelationship between cross-sectional and sagittal imaging in computer-assisted dental implant tomography
    Thunthy, KH
    DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (02) : 65 - 69
  • [43] Reproducibility of endothelial assessment during corneal organ culture: Comparison of a computer-assisted analyzer with manual methods
    Deb-Joardar, Nilanjana
    Thuret, Gilles
    Gavet, Yann
    Acquart, Sophie
    Garraud, Olivier
    Egelhoffer, Harald
    Gain, Philippe
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (05) : 2062 - 2067
  • [44] Optimization of cup positioning in THA - Comparison between conventional mechanical instrumentation and computer-assisted implanted cups by using the orthopilot navigation system
    Ottersbach, A
    Haaker, R
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2005, 143 (06): : 611 - 615
  • [45] Comparison of Manual Versus Computer-Assisted Automated Scoring of Limited Sleep Studies Using the SomnoMedics Software
    Shah, Syed Waheed
    Russell, Audrey
    Nolan, Geraldine
    Mc Nicholas, Walter
    Ryan, Silke
    IRISH JOURNAL OF MEDICAL SCIENCE, 2016, 185 : S504 - S504
  • [47] A prospective randomised comparison of video-assisted and computer-assisted disease eduction for children with chronic arthritis.
    Shaw, KL
    Hackett, J
    Whitworth, P
    Barlow, JH
    Wright, C
    Cheseldine, D
    Young, SP
    ARTHRITIS AND RHEUMATISM, 2001, 44 (09): : S169 - S169
  • [48] Comparison of the accuracy of dental implant placement using static and dynamic computer-assisted systems: an in vitro study
    Zhou, Miao
    Zhou, Hui
    Li, Shu-Yi
    Zhu, Yi-Bo
    Geng, Yuan-Ming
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2021, 122 (04) : 343 - 348
  • [49] Dynamic and static computer-assisted implant surgery for completely edentulous patients. A proof of a concept
    Pomares-Puig, Carmen
    Sanchez-Garces, M. Angeles
    Jorba-Garcia, Adria
    JOURNAL OF DENTISTRY, 2023, 130
  • [50] Comparison of speech perception between monaural and binaural hearing in cochlear implant patients
    Iwaki, T
    Matsushiro, N
    Mah, SR
    Sato, T
    Yasuoka, E
    Yamamoto, KI
    Kubo, T
    ACTA OTO-LARYNGOLOGICA, 2004, 124 (04) : 358 - 362