Kinetics of metal detection by luminescence-based whole-cell biosensors: connecting biosensor response to metal bioavailability, speciation and cell metabolism

被引:1
|
作者
Duval, Jerome F. L. [1 ]
Maffei, Lorenzo [2 ]
Delatour, Eva [2 ]
Zaffino, Marie [2 ]
Pagnout, Christophe [2 ]
机构
[1] Univ Lorraine, CNRS, LIEC, F-54000 Nancy, France
[2] Univ Lorraine, CNRS, LIEC, F-57000 Metz, France
关键词
ION-BINDING; DYNAMICS; BIOINTERPHASES; CHEMODYNAMICS; COMPLEXATION; BIOUPTAKE; DEPLETION; MODEL; SOFT; NANOPARTICLES;
D O I
10.1039/d3cp04653b
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Luminescent whole-cell metal biosensors are genetically engineered cells used for the detection of metals in e.g. aqueous solutions. Herein, we detail the quantitative connections between time-response of luminescent bacterial metal sensors and the bioavailability of free and complexed metal species. To that end, we formulate the biophysicochemical dynamics of metal partitioning at a biosensor/solution interface and integrate the required metabolism contribution to cell response. The formalism explains the ways in which cell signal depends on: coupled Eigen kinetics of metal complexation and diffusion of metal species to/from the interface; kinetics of metal excretion, Michaelis-Menten bioaccumulation and ensuing metal depletion from bulk solution; and kinetics of bioluminescence production following intracellular metal sequestration by regulatory metalloproteins. In turn, an expression is derived for the time-dependent cell signal as a function of interrelated (bioavai)lability of metal species and (thermo)dynamic descriptors of extra/intracellular metal complexation. Quantitative criteria are elaborated to identify scenarios where equilibrium modeling of metal speciation is incorrect, bulk metal depletion is operative, metal biouptake kinetics is governed by metal diffusion, or labile metal complexes fully contribute to cell response. Remarkably, in agreement with experiments, the theory predicts time-shifts of bioluminescence peaks with increasing concentration of biosensor and/or metal ligand in solution. We show that these shifts originate from the crosstalk between activation kinetics of cell photoactivity and speciation-dependent kinetics of bulk metal depletion. Overall, the work paves the way for the elaboration of new strategies to exploit the bioluminescence response of metal lux-biosensors at a dynamic level and evaluate metal bioavailability properties in environmental or biological aqueous samples. A mechanistic theory is developed to formulate the bioluminescence signal produced by metal-responsive whole-cell lux-bacterial sensors. It details how the signal reflects metal bioavailability-speciation processes and cell metabolism contribution.
引用
收藏
页码:30276 / 30295
页数:20
相关论文
共 50 条
  • [41] Whole-cell based label-free capacitive biosensor for rapid nanosize-dependent toxicity detection
    Qureshi, Anjum
    Pandey, Ashish
    Chouhan, Raghuraj S.
    Gurbuz, Yasar
    Niazi, Javed H.
    BIOSENSORS & BIOELECTRONICS, 2015, 67 : 100 - 106
  • [42] Pigment-based whole-cell biosensor system for cadmium detection using genetically engineered Deinococcus radiodurans
    Min-Ho Joe
    Kang-Hee Lee
    Sang-Yong Lim
    Seong-Hun Im
    Hyun-Pa Song
    In Soo Lee
    Dong-Ho Kim
    Bioprocess and Biosystems Engineering, 2012, 35 : 265 - 272
  • [43] Engineered Whole-Cell-Based Biosensors: Sensing Environmental Heavy Metal Pollutants in Water—a Review
    Shrute Kannappan
    Bhaskar Chandra Mohan Ramisetty
    Applied Biochemistry and Biotechnology, 2022, 194 : 1814 - 1840
  • [44] Whole-cell biosensor engineering based on the transcription factor XylS/Pm for sensitive detection of PCB intermediate chlorobenzoic acid
    Xian, Yufan
    Zhang, Faying
    Wang, Meixing
    Zhao, Xiang
    Sun, Xuting
    Lu, Zhenghui
    Zhang, Guimin
    BIOCHEMICAL ENGINEERING JOURNAL, 2024, 202
  • [45] A bi-enzymatic whole cell conductometric biosensor for heavy metal ions and pesticides detection in water samples
    Chouteau, C
    Dzyadevych, S
    Durrieu, C
    Chovelon, JM
    BIOSENSORS & BIOELECTRONICS, 2005, 21 (02): : 273 - 281
  • [46] Engineered Whole-Cell-Based Biosensors: Sensing Environmental Heavy Metal Pollutants in Water-a Review
    Kannappan, Shrute
    Ramisetty, Bhaskar Chandra Mohan
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2022, 194 (04) : 1814 - 1840
  • [47] Detection of 2,4-dichlorophenoxyacetic acid herbicide using a FGE-sulfatase based whole-cell Agrobacterium biosensor
    Ritcharoon, Benjarat
    Sallabhan, Ratiboot
    Toewiwat, Neal
    Mongkolsuk, Skorn
    Loprasert, Suvit
    JOURNAL OF MICROBIOLOGICAL METHODS, 2020, 175
  • [48] Biosensors in Monitoring Water Quality and Safety: An Example of a Miniaturizable Whole-Cell Based Sensor for Hg2+ Optical Detection in Water
    Sciuto, Emanuele Luigi
    Coniglio, Maria Anna
    Corso, Domenico
    van der Meer, Jan Roelof
    Acerbi, Fabio
    Gola, Alberto
    Libertino, Sebania
    WATER, 2019, 11 (10)
  • [49] Metal-organic frameworks-based biosensor for microRNA detection in prostate cancer cell lines
    Najafabadi, Milad Ahmadi
    Yousefi, Fatemeh
    Rasaee, Mohammad J. J.
    Soleimani, Masoud
    Kazemzad, Mahmood
    RSC ADVANCES, 2022, 12 (54) : 35170 - 35180
  • [50] Functional GFP-metallothionein fusion protein from Tetrahymena thermophila: a potential whole-cell biosensor for monitoring heavy metal pollution and a cell model to study metallothionein overproduction effects
    Amaro, Francisco
    Turkewitz, Aaron P.
    Martin-Gonzalez, Ana
    Carlos Gutierrez, Juan
    BIOMETALS, 2014, 27 (01) : 195 - 205