X-Ray CdZnTe Detector in Transverse and Longitudinal Photoconductivity Mode

被引:0
|
作者
Dikaev, Yu. M. [1 ]
Kudryashov, A. A. [1 ]
机构
[1] Russian Acad Sci, Fryazino Branch, Kotelnikov Inst Radio Engn & Elect, Fryazino 141190, Moscow, Russia
关键词
CdZnTe detector; efficient energy; X-ray radiation; resistance; photocurrent; photoconductivity;
D O I
10.1134/S1063784223900590
中图分类号
O59 [应用物理学];
学科分类号
摘要
The work considers "transverse" and "longitudinal" photoconductivity modes, regarding the direction of radiation, photoconductivity in semiconductor detectors of CdZnTe. Mathematical calculations were made from the representation of the internal area of the detector in the form of radiation absorption sites. The results of the calculations are compared with experimentally measured photocurrent of the detector with a cross section of 2 x 2 mm CdZnTe from the direction of its radiation by X-ray. From the ratio of photocurrents in the range of X-ray radiation energies 35-72 keV for these two cases, a linear coefficient of X-ray absorption by the CdZnTe detector is determined.
引用
收藏
页码:S415 / S417
页数:3
相关论文
共 50 条
  • [1] X-Ray CdZnTe Detector in Transverse and Longitudinal Photoconductivity Mode
    Yu. M. Dikaev
    A. A. Kudryashov
    [J]. Technical Physics, 2023, 68 : S415 - S417
  • [2] CdZnTe detector as an x-ray spectrometer
    Miyajima, S
    Sakuragi, H
    Matsumoto, M
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 148 - 155
  • [3] CdZnTe detector in diagnostic x-ray spectroscopy
    Miyajima, S
    Imagawa, K
    Matsumoto, M
    [J]. MEDICAL PHYSICS, 2002, 29 (07) : 1421 - 1429
  • [4] CdZnTe detector in mammographic x-ray spectroscopy
    Miyajima, S
    Imagawa, K
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (22): : 3959 - 3972
  • [5] Progress in development on CdZnTe x-ray detector
    Zhou, Yongdong
    Zhou, Ning
    Zhang, Linhu
    Wang, Jin
    Wan, Aihua
    [J]. SEMICONDUCTOR PHOTODETECTORS III, 2006, 6119
  • [6] Temporal pulsed x-ray response of CdZnTe: In detector
    Guo, Rong-Rong
    Xu, Ya-Dong
    Zha, Gang-Qiang
    Wang, Tao
    Jie, Wan-Qi
    [J]. CHINESE PHYSICS B, 2018, 27 (12)
  • [7] X-Ray Spectroscopy with a Room Temperature CdZnTe Detector
    Fritz, S. G.
    Shikhaliev, P. M.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [8] CdZnTe detector for combined x-ray CT and SPECT
    Iwata, K
    Hasegawa, BH
    Heanue, JA
    Bennett, PR
    Shah, KS
    Boles, CD
    Boser, BE
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 740 - 744
  • [9] Temporal pulsed x-ray response of CdZnTe:In detector
    郭榕榕
    徐亚东
    查钢强
    王涛
    介万奇
    [J]. Chinese Physics B, 2018, 27 (12) : 454 - 458
  • [10] The X-ray Radiation Response of CdZnTe Crystal Nuclear Detector
    Dai, X. Y.
    Meng, H.
    Zhang, Y. L.
    Tao, J.
    Xu, R.
    Zhang, J. J.
    Huang, J.
    Wang, L.
    Tang, K.
    Min, J. H.
    Wang, L. J.
    [J]. PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY AND MANAGEMENT SCIENCE (ITMS 2015), 2015, 34 : 1296 - 1299