Rotational Stability, Decentration, and Tilt of a New Hydrophobic Acrylic Intraocular Lens

被引:0
|
作者
Roggla, Veronika [1 ]
Schartmueller, Daniel [1 ]
Schwarzenbacher, Luca [1 ]
Leydolt, Christina [1 ]
Menapace, Rupert [1 ,2 ]
机构
[1] Med Univ Vienna, Dept Ophthalmol & Optometry, Vienna, Austria
[2] Med Univ Vienna, Dept Ophthalmol, Vienna, Austria
关键词
PHOTOGRAPHY; ASTIGMATISM;
D O I
10.1016/j.ajo.2023.01.026
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate rotational stability, decentration and tilt of the monofocal intraocular lens (IOL) Nanex (NC1-SP; HOYA Surgical Optics). DESIGN: Prospective interventional case series. METHODS: The study was performed at the Department of Ophthalmology, Medical University of Vienna. The study population comprised 130 eyes of 68 patients with age-related cataract who underwent cataract surgery with implantation of a Nanex IOL. Baseline image for rotational stability evaluation was obtained at the end of surgery (EoS) and compared to retroillumination images taken at 1 hour, 1 week, 1 month, and 6 months after surgery. Axis alignment was assessed using nonmovable landmarks on the sclera and the optic-haptic junctions of the IOL. Anterior segment OCT images were performed to evaluate decentration and tilt. The main outcome measure was absolute rotation from EoS to 6 months postoperatively. RESULTS: Median IOL rotation of all eyes from EoS to 6 months was 1.9° (interquartile range 0.1°-37.5°). Ten eyes (9.71%) rotated more than 5° and 2 eyes (1.94%), more than 10°. IOL rotation did not correlate with axial eye length (Spearman r = –0.042, P = .46), crystalline lens thickness (Spearman r = 0.134, P = .19), and crystalline lens equatorial diameter (Spearman r = 0.101, P = .325). IOL rotation positively correlated with anterior fibrosis severity (Spearman r = 0.321, P = .002). Preoperative decentration (0.2 ± 0.12 mm) and tilt (5.7 ± 1.6°) did not change significantly after surgery (0.22 ± 0.12 mm and 5.62 ± 1.49°, respectively). CONCLUSION: The investigated IOL presented good rotational stability and low decentration and tilt values. Nevertheless, anterior capsule fibrosis development led to a higher tendency of IOL rotation after 1 week. © 2023 The Authors
引用
收藏
页码:149 / 156
页数:8
相关论文
共 50 条
  • [1] Rotational stability of a new hydrophobic acrylic intraocular lens platform
    Werner, Liliana
    Hawn, Vivian S.
    Bundogji, Nour
    Eid, Kevin
    Kelkar, Neil
    Renschler, Andy
    Mamalis, Nick
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (03): : 289 - 294
  • [2] Rotational stability and refractive outcomes of a new hydrophobic acrylic toric intraocular lens
    Schartmueller, Daniel
    Lisy, Marcus
    Mahnert, Nikolaus
    Schranz, Markus
    Danzinger, Victor
    Schwarzenbacher, Luca
    Pieh, Stefan
    Abela-Formanek, Claudette
    Leydolt, Christina
    Menapace, Rupert
    [J]. EYE AND VISION, 2024, 11 (01)
  • [3] Influence of a capsular tension ring on rotational stability, decentration and tilt of a 11.0 mm hydrophobic acrylic plate haptic intraocular lens - An intraindividual comparative study
    Schartmueller, Daniel
    Roeggla, Veronika
    Schwarzenbacher, Luca
    Abela-Formanek, Claudette
    Leydolt, Christina
    Menapace, Rupert
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [4] Rotational stability of a hydrophobic-acrylic aspheric toric intraocular lens
    Kasthurirangan, Sanjeev
    Nixon, Don
    Feuchter, Lucas
    Smith, Pamela
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [5] The role of capsulotomy and intraocular lens type on tilt and decentration of polymethylmethacrylate and foldable acrylic lenses
    Mutlu, FM
    Bilge, AH
    Altinsoy, HI
    Yumusak, E
    [J]. OPHTHALMOLOGICA, 1998, 212 (06) : 359 - 363
  • [6] Decentration and Tilt of Intraocular Lens after Posterior Capsulotomy
    Uzel, Mehmet Murat
    Ozates, Serdar
    Koc, Mustafa
    Uzel, Ayse Guzin Taslipinar
    Yilmazbas, Pelin
    [J]. SEMINARS IN OPHTHALMOLOGY, 2018, 33 (06) : 766 - 771
  • [7] Influence of intraocular lens tilt and decentration on wavefront aberrations
    Taketani, F
    Matuura, T
    Yukawa, E
    Hara, Y
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (10): : 2158 - 2162
  • [8] MEASUREMENT OF INTRAOCULAR-LENS DECENTRATION AND TILT INVIVO
    PHILLIPS, P
    PEREZEMMANUELLI, J
    ROSSKOTHEN, HD
    KOESTER, CJ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (02): : 129 - 135
  • [9] Comparison of tilt and decentration of 1-piece and 3-piece hydrophobic acrylic intraocular lenses
    Mutlu, FM
    Erdurman, C
    Sobaci, G
    Bayraktar, MZ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (02): : 343 - 347
  • [10] Glistening formation in a new hydrophobic acrylic intraocular lens
    Timur M. Yildirim
    Hui Fang
    Sonja K. Schickhardt
    Qiang Wang
    Patrick R. Merz
    Gerd U. Auffarth
    [J]. BMC Ophthalmology, 20