Control strategy for the anode gas supply system in a proton exchange membrane fuel cell system

被引:1
|
作者
Li, Xingyi [1 ,2 ]
Wei, Heng [1 ,2 ]
Du, Changqing [1 ,2 ,3 ]
Shi, Chenxu [1 ,2 ]
Zhang, Jiaming [1 ,2 ]
机构
[1] Wuhan Univ Technol, Hubei Key Lab Adv Technol Automot Components, Wuhan 430070, Peoples R China
[2] Wuhan Univ Technol, Hubei Res Ctr New Energy & Intelligent Connected V, Wuhan 430070, Peoples R China
[3] Foshan Xianhu Lab, Adv Energy Sci & Technol Guangdong Lab, Foshan 528200, Peoples R China
关键词
Fuel cell system; Anode pressure control; Second-order active disturbance rejection; controller (SOADRC); Error integral criterion; Bench experiment; PREDICTIVE CONTROL; HYDROGEN PRESSURE;
D O I
10.1016/j.egyr.2023.10.079
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Stable pressure control can improve the lifespan, efficiency, and stability of proton exchange membrane fuel cell system (PEMFCs). We successfully implemented a feedforward-based proportion-integral controller (FPIC) to control the anode pressure of a 100 kW fuel cell system. The bench experimental results demonstrate that the fuel cell stack achieves a maximum efficiency of 62.3 %, while the fuel cell power generation system achieve a maximum efficiency of 53.5 %. Under the steady-state and dynamic conditions, the strategy achieves a pressure tracking control accuracy of 98.93 % and 94.47 %, respectively. To address the large overshoot phenomenon and slow response speed of the FPIC when controlling the anode pressure, we further design a second order active disturbance rejection controller (SOADRC). The simulation results show that the SOADRC exhibits higher control stability and lower overshoot than FPIC. Moreover, it demonstrates a 51.3 % increase in response speed and an 80.7 % improvement in control stability under steady-state conditions compared to FPIC. The evaluation metrics for the error integral criterion (eISE = 0.023, eITSE = 2.58, eIAE = 0.35, and eIEAE = 36.76) are lower than FPIC, which demonstrates that the SOADRC provides more precise control of anode pressure, and enhances the stability of PEMFCs.
引用
收藏
页码:4342 / 4358
页数:17
相关论文
共 50 条
  • [41] Adaptive control of oxygen excess ratio in a proton exchange membrane fuel cell system
    Wu, Di
    Li, Kai
    Gao, Yan
    Yin, Cong
    Tang, Hao
    ENERGY REPORTS, 2022, 8 : 328 - 335
  • [42] Modelling, simulation and control of a proton exchange membrane fuel cell (PEMFC) power system
    Al-Dabbagh, Ahmad W.
    Lu, Lixuan
    Mazza, Antonio
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (10) : 5061 - 5069
  • [43] Low power proton exchange membrane fuel cell system identification and adaptive control
    Yang, Yee-Pien
    Wang, Fu-Cheng
    Chang, Hsin-Ping
    Ma, Ying-Wei
    Weng, Biing-Jyh
    JOURNAL OF POWER SOURCES, 2007, 164 (02) : 761 - 771
  • [44] Proton exchange membrane fuel cell system model for automotive vehicle simulation and control
    Paganelli, G
    Guezennec, YG
    Rizzoni, G
    Moran, MJ
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2002, 124 (01): : 20 - 27
  • [45] Fuzzy Logic based Control Strategies for Proton Exchange Membrane Fuel Cell System
    Mahali, Annada Prasad
    Gara, Uday Bhaskar Babu
    Mullapudi, Siva
    IFAC PAPERSONLINE, 2022, 55 (01): : 703 - 708
  • [46] Thermal management strategy for a proton exchange membrane fuel cell system with a large active cell area
    Yu, Sangseok
    Jung, Dohoy
    RENEWABLE ENERGY, 2008, 33 (12) : 2540 - 2548
  • [47] Multiple model predictive control for a hybrid proton exchange membrane fuel cell system
    Chen, Qihong
    Gao, Lijun
    Dougal, Roger A.
    Quan, Shuhai
    JOURNAL OF POWER SOURCES, 2009, 191 (02) : 473 - 482
  • [48] Air supply state model for a Proton Exchange Membrane Fuel Cell control
    Hassanaly, N.
    Agbossou, K.
    Dube, Y.
    Adzakpa, K. P.
    2007 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-3, 2007, : 1511 - 1514
  • [49] Interval-based LQR strategy for optimal control of proton exchange membrane fuel cell system with interval uncertainties
    Yuan Zhi
    Wang Weiqing
    He Shan
    Mizzi, Scott
    ISA TRANSACTIONS, 2020, 100 : 334 - 345
  • [50] Control-oriented LPV Modeling for the Air Supply System of Proton Exchange Membrane Fuel Cells
    Chen, F. X.
    Jiao, J. R.
    Liu, S. G.
    Yu, Y.
    Xu, S. C.
    FUEL CELLS, 2018, 18 (04) : 433 - 440