Design optimization and experimental demonstration of a gravity-assisted cryogenic loop heat pipe

被引:2
|
作者
Chang, Xinyu [1 ]
Yokouchi, Takeshi [1 ]
Odagiri, Kimihide [2 ]
Ogawa, Hiroyuki [2 ]
Nagano, Hosei [3 ]
Nagai, Hiroki [1 ]
机构
[1] Tohoku Univ, Inst Fluid Sci, Aoba Ku, Sendai 9808577, Japan
[2] Japan Aerosp Explorat Agcy, Inst Space & Astronaut Sci, Sagamihara, Kanagawa 2525210, Japan
[3] Nagoya Univ, Furo Cho,Chikusa Ku, Nagoya 4648601, Japan
关键词
Loop heat pipe; Cryogenic cooling; Two-phase flow; Design method; Demonstration test; SUPERCRITICAL STARTUP; OPERATING CHARACTERISTICS; THERMAL PERFORMANCE; COMPONENT LAYOUT; WORKING FLUID; ACROSS-GIMBAL;
D O I
10.1016/j.ijheatmasstransfer.2023.125037
中图分类号
O414.1 [热力学];
学科分类号
摘要
Cryogenic loop heat pipe (CLHP) is an efficient two-phase heat transfer device utilized for cooling electronic components within a cryogenic operating temperature range (3-220 K), such as an infrared detector and superconductive magnet. Compared with the prevalent cryogenic loop heat pipe which uses a capillary starter pump to achieve the startup, this research studied a gravity-assisted CLHP that uses gravity to achieve the startup. In this way, the configuration of gravity-assisted CLHP became simple, and the preconditioning could be achieved without consuming the extra heat load on the capillary starter pump. This proposed CLHP is intended for use in ground and space (in the gravitational environment such as the Moon and Mars). A comprehensive design method including the design optimization of the gas reservoir and compensation chamber (CC) volumes was newly established by considering the variation of vapor-liquid distribution in CC during the operating temperature range, resulting in a significant reduction of at least 40 % in the gas reservoir volume compared to conventional CLHP designs. Then the fabrication and the experimental investigation were implemented. Nitrogen was selected as the working fluid. The CLHP was designed to transport heat exceeding 20 W over a distance of 2 m within the operating temperature range of 80-110 K. Based on the experimental result, the startup was achieved, and the heat transfer performance satisfied the design requirement. Additionally, the detailed operating characteristics of the CLHP, including the gravity effect, the startup behavior, and the hysteresis phenomena that occurred in the temperature of the evaporator, pressure, and thermal resistance, were also first reported and thoroughly investigated.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Numerical simulation on steady-state heat transfer characteristic of a novel gravity-assisted heat pipe heat exchanger
    Cao, X. (xlcao@csu.edu.cn), 1689, Central South University of Technology (44):
  • [42] PERFORMANCE LIMITS IN GRAVITY-ASSISTED HYDROGEN HEAT PIPES
    HILL, DD
    PRENGER, FC
    BARCLAY, JA
    CHEMICAL ENGINEERING COMMUNICATIONS, 1989, 85 : 157 - 167
  • [43] Numerical simulation and performance optimization of a new loop gravity heat pipe
    Chen J.
    Liu J.
    Xu X.
    Yu Y.
    Huagong Xuebao/CIESC Journal, 2023, 74 (02): : 721 - 734
  • [44] Experimental investigation of gravity-assisted wickless heat pipes (thermosyphons) at low heat inputs for solar application
    Al-Joboory, Hassan Naji Salman
    ARCHIVES OF THERMODYNAMICS, 2020, 41 (02) : 257 - 276
  • [45] Experimental investigation and optimization of loop heat pipe performance with nanofluids
    Muhammad Arif Bin Harun
    Prem A./L. Gunnasegaran
    Nor Azwadi Che Sidik
    M’hamed Beriache
    Javad Ghaderian
    Journal of Thermal Analysis and Calorimetry, 2021, 144 : 1435 - 1449
  • [46] Experimental investigation and optimization of loop heat pipe performance with nanofluids
    Bin Harun, Muhammad Arif
    Gunnasegaran, Prem A. L.
    Sidik, Nor Azwadi Che
    Beriache, M'hamed
    Ghaderian, Javad
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 144 (04) : 1435 - 1449
  • [47] PERFORMANCE-CHARACTERISTICS OF GRAVITY-ASSISTED POTASSIUM HEAT PIPES
    PRENGER, FC
    KEDDY, ES
    SENA, JT
    JOURNAL OF SPACECRAFT AND ROCKETS, 1986, 23 (04) : 407 - 410
  • [48] Effect of vessel dimensional ratio on heat conveyance capabilities of gravity-assisted heat pipes: Theoretical and experimental approach
    De Leon-Ruiz, J. E.
    Beltran-Chacon, R.
    Carvajal-Mariscal, I.
    Venegas, M.
    De La Cruz-Avila, M.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 45
  • [49] Gravity-Assisted Heat Pipe With Strong Marangoni Fluid for Waste Heat Management of Single and Dual-Junction Solar Cells
    Armijo, Kenneth M.
    Carey, Van P.
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (02):
  • [50] EXPERIMENTS WITH GRAVITY-ASSISTED HEAT PIPES WITH AND WITHOUT CIRCUMFERENTIAL GROOVES
    FELDMAN, KT
    MUNJE, S
    JOURNAL OF ENERGY, 1979, 3 (04): : 211 - 216