Design optimization and experimental demonstration of a gravity-assisted cryogenic loop heat pipe

被引:2
|
作者
Chang, Xinyu [1 ]
Yokouchi, Takeshi [1 ]
Odagiri, Kimihide [2 ]
Ogawa, Hiroyuki [2 ]
Nagano, Hosei [3 ]
Nagai, Hiroki [1 ]
机构
[1] Tohoku Univ, Inst Fluid Sci, Aoba Ku, Sendai 9808577, Japan
[2] Japan Aerosp Explorat Agcy, Inst Space & Astronaut Sci, Sagamihara, Kanagawa 2525210, Japan
[3] Nagoya Univ, Furo Cho,Chikusa Ku, Nagoya 4648601, Japan
关键词
Loop heat pipe; Cryogenic cooling; Two-phase flow; Design method; Demonstration test; SUPERCRITICAL STARTUP; OPERATING CHARACTERISTICS; THERMAL PERFORMANCE; COMPONENT LAYOUT; WORKING FLUID; ACROSS-GIMBAL;
D O I
10.1016/j.ijheatmasstransfer.2023.125037
中图分类号
O414.1 [热力学];
学科分类号
摘要
Cryogenic loop heat pipe (CLHP) is an efficient two-phase heat transfer device utilized for cooling electronic components within a cryogenic operating temperature range (3-220 K), such as an infrared detector and superconductive magnet. Compared with the prevalent cryogenic loop heat pipe which uses a capillary starter pump to achieve the startup, this research studied a gravity-assisted CLHP that uses gravity to achieve the startup. In this way, the configuration of gravity-assisted CLHP became simple, and the preconditioning could be achieved without consuming the extra heat load on the capillary starter pump. This proposed CLHP is intended for use in ground and space (in the gravitational environment such as the Moon and Mars). A comprehensive design method including the design optimization of the gas reservoir and compensation chamber (CC) volumes was newly established by considering the variation of vapor-liquid distribution in CC during the operating temperature range, resulting in a significant reduction of at least 40 % in the gas reservoir volume compared to conventional CLHP designs. Then the fabrication and the experimental investigation were implemented. Nitrogen was selected as the working fluid. The CLHP was designed to transport heat exceeding 20 W over a distance of 2 m within the operating temperature range of 80-110 K. Based on the experimental result, the startup was achieved, and the heat transfer performance satisfied the design requirement. Additionally, the detailed operating characteristics of the CLHP, including the gravity effect, the startup behavior, and the hysteresis phenomena that occurred in the temperature of the evaporator, pressure, and thermal resistance, were also first reported and thoroughly investigated.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Effect of filling pressure on operating characteristics of a gravity-assisted nitrogen cryogenic loop heat pipe
    Yokouchi, Takeshi
    Chang, Xinyu
    Odagiri, Kimihide
    Ogawa, Hiroyuki
    Nagano, Hosei
    Nagai, Hiroki
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 231
  • [2] A DESIGN PROCEDURE FOR GRAVITY-ASSISTED HEAT PIPE HEAT-EXCHANGER
    AZAD, E
    GEOOLA, F
    JOURNAL OF HEAT RECOVERY SYSTEMS, 1984, 4 (02): : 101 - 111
  • [3] Optimization of Finned-Tube Heat Exchanger in a Gravity-Assisted Separated Heat Pipe
    Rong, Yangyiming
    Su, Weitao
    Wang, Shuai
    Du, Bowen
    Wei, Jianjian
    Zhang, Shaozhi
    FRONTIERS IN HEAT AND MASS TRANSFER, 2024, 22 : 1209 - 1229
  • [4] DESIGN OF WATER-TO-AIR GRAVITY-ASSISTED HEAT PIPE HEAT-EXCHANGER
    AZAD, E
    BAHAR, F
    MOZTARZADEH, F
    JOURNAL OF HEAT RECOVERY SYSTEMS, 1985, 5 (02): : 89 - 99
  • [5] Experimental Study on the Impact of Lubricant on the Performance of Gravity-Assisted Separated Heat Pipe
    Rongyang, Yiming
    Su, Weitao
    Mao, Zujun
    Huang, Wenlin
    Du, Bowen
    Zhang, Shaozhi
    ENERGIES, 2024, 17 (15)
  • [6] Design and experimental investigation of a neon cryogenic loop heat pipe
    Jiang He
    Yuandong Guo
    Hongxing Zhang
    Jianyin Miao
    Lu Wang
    Guiping Lin
    Heat and Mass Transfer, 2017, 53 : 3229 - 3239
  • [7] Design and experimental investigation of a neon cryogenic loop heat pipe
    He, Jiang
    Guo, Yuandong
    Zhang, Hongxing
    Miao, Jianyin
    Wang, Lu
    Lin, Guiping
    HEAT AND MASS TRANSFER, 2017, 53 (11) : 3229 - 3239
  • [9] Steady-state modeling and analysis of a loop heat pipe under gravity-assisted operation
    Bai, Lizhan
    Guo, Jinghui
    Lin, Guiping
    He, Jiang
    Wen, Dongsheng
    APPLIED THERMAL ENGINEERING, 2015, 83 : 88 - 97
  • [10] Experimental study of a photovoltaic solar-assisted heat pump/gravity-assisted heat pipe hybrid system
    Zhang, T.
    Zhang, Y. F.
    Shi, Z. R.
    Li, Q. F.
    Cai, J. Y.
    RENEWABLE ENERGY, 2023, 207 : 147 - 161