FRACTURE SAFETY OF LIQUEFIED NATURAL GAS TANK IN CRYOGENIC CONDITIONS

被引:0
|
作者
An, G. [1 ]
Park, J. [2 ]
Seong, D. [1 ]
Han, I [3 ]
机构
[1] Chosun Univ, Dept Naval Architecture & Ocean Engn, Gwangju, South Korea
[2] Chosun Univ, Dept Civil Engn, Gwangju, South Korea
[3] POSCO, Tech Res Lab, Incheon, South Korea
来源
关键词
unstable ductile fracture; fracture toughness; cryogenic steel; LNG storage/fuel tank; crack tip opening displacement test; wide plate tensile test;
D O I
10.5750/ijme.v165iA1.1208
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
High-manganese austenitic steel has been developed as a new cryogenic steel for application in liquified natural gas (LNG) storage and fuel tanks, with improved fracture toughness and safety at cryogenic temperatures. Generally, the fracture toughness decreases at lower temperatures; therefore, cryogenic steel requires a high fracture toughness to prevent unstable fractures. This study conducted unstable ductile fracture tests with 30-mm-thick high-manganese austenitic steel and evaluated its applicability to LNG storage and fuel tanks. The ductile fracture resistance in the weld joints was evaluated, including the weld metal and heat-affected zone. The unstable fracture resistance was evaluated for different LNG tank types. It was found that high-manganese austenitic steel has excellent unstable fracture characteristics and good material performance as a cryogenic steel; therefore, it can be applied in LNG storage and fuel tanks.
引用
收藏
页码:A115 / A124
页数:10
相关论文
共 50 条
  • [31] Numerical simulation and experimental study of sloshing in an liquefied natural gas tank
    State Key Laboratory of Ocean Engineering, Shanghai Jiaotong University, Shanghai 200030, China
    Shanghai Jiaotong Daxue Xuebao, 2009, 10 (1559-1563):
  • [32] Study on liquefied natural gas safety dispersion distance
    Feng Zhihua
    He Xueqiu
    Nie Baisheng
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 6, PTS A AND B, 2006, 6 : 1237 - 1241
  • [33] LIQUEFIED NATURAL GAS SAFETY THROUGH CONTROL.
    Warner, Vincent A.
    Professional Safety, 1975, 20 (01): : 40 - 45
  • [34] Design and thermal safety assessment of a liquefied-petroleum-gas tank lorry
    Chen, HJ
    Chang, SH
    JOURNAL OF THE CHINESE INSTITUTE OF CHEMICAL ENGINEERS, 2000, 31 (01): : 99 - 104
  • [35] Forensic analysis on bursting accident of buffer tank in liquefied natural gas bus
    Chai, Jun-Hui
    Lv, Zhong-Jie
    Shen, Zheng-Xiang
    Huan, Huang-Dong
    Zhang, Xiao-Long
    Zhang, Zi-Jiang
    Xu, Bo
    JOURNAL OF FORENSIC SCIENCES, 2021, 66 (04) : 1557 - 1563
  • [36] Application of Cryogenic Energy Storage to Liquefied Natural Gas Regasification Power Plant
    Park, Jinwoo
    Lee, Inkyu
    Yoon, Hyungjoon
    Kim, Jiyong
    Moon, Il
    27TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, PT C, 2017, 40C : 2557 - 2562
  • [37] Analysis of temperature and pressure changes in liquefied natural gas (LNG) cryogenic tanks
    Chen, QS
    Wegrzyn, J
    Prasad, V
    CRYOGENICS, 2004, 44 (10) : 701 - 709
  • [38] Using cryogenic exergy of liquefied natural gas for electricity production with the Stirling cycle
    Dong, Hui
    Zhao, Liang
    Zhang, Songyuan
    Wang, Aihua
    Cai, Jiuju
    ENERGY, 2013, 63 : 10 - 18
  • [39] Cryogenic reliability of composite insulation panels for liquefied natural gas (LNG) ships
    Yu, Young Ho
    Kim, Bu Gi
    Lee, Dai Gil
    COMPOSITE STRUCTURES, 2012, 94 (02) : 462 - 468
  • [40] A prototype test of dynamic boil-off gas in liquefied natural gas tank containers
    Yu, Peng
    Yin, Yuan-chao
    Wei, Zhi-jun
    Yue, Qian-jin
    APPLIED THERMAL ENGINEERING, 2020, 180