Comparison of the dose distribution of the VMAT radiotherapy technique depending on the beam used: FFF-X10MV and FFF-X15MV

被引:1
|
作者
Plaza, Dominika [1 ,2 ]
Sroka, Lukasz [1 ]
Orzechowska, Klaudia [1 ]
Slosarek, Krzysztof [1 ]
机构
[1] Maria Sklodowska Curie Natl Res Inst Oncol, Radiotherapy Planning Dept, Gliwice Branch, Gliwice, Poland
[2] Narodowy Inst Onkol, Panstwowy Inst Badawczy, Zaklad Planowan Radioterapii, Oddzial Gliwicach, Ul Wybrzeze Armii Krajowej 15, PL-44102 Gliwice, Poland
关键词
flattening filter-free beams (FFF); flattening filter beams (FF); volumetric modulated arc therapy (VMAT); radiation planning index (RPI); RADIATION-THERAPY; FLATTENING FILTER; CANCER;
D O I
10.5603/rpor.97508
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The aim of the study was to answer the question of whether flattening filter (FF) and flattening filter-free (FFF) beams can be used alternately in the volumetric modulated arc therapy (VMAT) treatment technique, regardless of the size of the irradiated volume [small (S) or large (L) planning target volume (PTV)].Materials and methods: Two groups of patients were examined: a group with a S-PTV-laryngeal cancer and a group with a L-PTV - gynecological volume. For each patient, two treatment plans were made for beams (energies): FFF-X10MV and FF-X15MV. Then, a statistical analysis, nonparametric test, and independent groups were performed, comparing the beams' impact on the analyzed treatment plans.Results: In the case of laryngeal irradiation (S-PTV), there are no statistically significant differences between the energy used and the assessed parameters of the plan. In the case of gynecological volume (L-PTV), only statistically significant differences were noted for the number of monitor units depending on the energy used. For a large irradiated volume (gynecological case), the use of FFF beams increases the number of monitor units by 39,4% in relation to the FF beam.Conclusions: In the case of gynecological neoplasms, statistically significant differences were found in the number of monitor units. Therefore, in the case of irradiation of L-PTV, it is recommended that flattening-filtering beams are used due to the smaller number of monitors. In the case of S-PTV, no statistically significant differences were found between the types of beams used (FF or FFF) and the treatment plan parameters analyzed in the study.
引用
收藏
页码:654 / 660
页数:7
相关论文
共 44 条
  • [21] Treatment of Large-Size Prostate Cancer Patients On An O-Ring Linac with 6MV FFF: Plan Quality Comparison with a C-Arm Linac Using 10MV Or 15MV Photons
    Liu, B.
    Cheng, C.
    Wang, X.
    Zhu, J.
    Parikh, R.
    Nie, K.
    Yue, N.
    Zhang, Y.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [22] BEAM HARDENING OF 10 MV RADIOTHERAPY X-RAYS - ANALYSIS USING A CONVOLUTION SUPERPOSITION METHOD
    METCALFE, PE
    HOBAN, PW
    MURRAY, DC
    ROUND, WH
    PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (11): : 1533 - 1549
  • [23] Practical considerations for reporting surface dose in external beam radiotherapy: a 6 MV X-ray beam study
    Kim, J. -H.
    Hill, R.
    Kuncic, Z.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (03) : 271 - 282
  • [24] Accuracy of Novel Real-Time Tumor-Tracking Radiotherapy with KV-MV Simultaneous Irradiation Using High-Dose Rate FFF Beam
    Tanabe, S.
    Umetsu, O.
    Kuwabara, R.
    Kuribayashi, T.
    Sasage, T.
    Takatou, H.
    Kawaguchi, G.
    Utsunomiya, S.
    Aoyama, H.
    MEDICAL PHYSICS, 2019, 46 (06) : E244 - E244
  • [25] MEASUREMENT AND CALCULATION OF OVARY AND FETUS DOSE IN EXTENDED FIELD RADIOTHERAPY FOR 10 MV X-RAYS
    SHARMA, SC
    WILLIAMSON, JF
    KHAN, FM
    LEE, CKK
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (06): : 843 - 846
  • [26] Practical considerations for reporting surface dose in external beam radiotherapy: a 6 MV X-ray beam study
    J.-H. Kim
    R. Hill
    Z. Kuncic
    Australasian Physical & Engineering Sciences in Medicine, 2012, 35 : 271 - 282
  • [27] PERIPHERAL DOSE FROM 10MV X-RAY-BEAMS MODIFIED BY A BEAM SPOILER
    GRAVES, RG
    ZAGARS, G
    KOOY, H
    SIMPSON, LD
    HENZLER, M
    MEDICAL PHYSICS, 1984, 11 (03) : 382 - 382
  • [28] A combination of high dose rate (10X FFF/2400 MU/min/10 MV X-rays) and total low dose (0.5 Gy) induces a higher rate of apoptosis in melanoma cells in vitro and superior preservation of normal melanocytes
    Sarojini, Sreeja
    Pecora, Andrew
    Milinovikj, Natasha
    Barbiere, Joseph
    Gupta, Saakshi
    Hussain, Zeenathual M.
    Tuna, Mehmet
    Jiang, Jennifer
    Adrianzen, Laura
    Jun, Jaewook
    Catello, Laurice
    Sanchez, Diana
    Agarwal, Neha
    Jeong, Stephanie
    Jin, Youngjin
    Remache, Yvonne
    Goy, Andre
    Ndlovu, Alois
    Ingenito, Anthony
    Suh, K. Stephen
    MELANOMA RESEARCH, 2015, 25 (05) : 376 - 389
  • [29] Stereotactic Ablative Radiotherapy (SABR) for low, intermediate and high risk prostate cancer using Volumetric Modulated Arc Therapy (VMAT) with a 10x Flattening Filter Free (FFF) beam
    Mestrovic, A.
    Fortin, D.
    Alexander, A.
    MEDICAL PHYSICS, 2014, 41 (08) : 29 - 29
  • [30] Comparison Between the HYPERSCINT RP200 Scintillation Detector and Other Small Field Detectors for 10MV FFF SRS Beam Modelling On a VersaHD Linear Accelerator
    Morin, J.
    Cabana, J. F.
    Goulet, M.
    Theriault, D.
    MEDICAL PHYSICS, 2021, 48 (06)