A comparison of virtually mounted dental casts from traditional facebow records, average values, and 3D facial scans

被引:8
|
作者
Inoue, Natalie [1 ]
Scialabba, Rebecca [2 ]
Lee, Jason D. [3 ]
Lee, Sang J. [3 ,4 ]
机构
[1] Harvard Sch Dent Med, Dept Restorat Dent & Biomat Sci, Adv Grad Prosthodont, Boston, MA USA
[2] Harvard Sch Dent Med, Boston, MA USA
[3] Harvard Sch Dent Med, Dept Restorat Dent & Biomat Sci, Boston, MA USA
[4] Harvard Sch Dent Med, Dept Restorat Dent & Biomat Sci, 188 Longwood Ave, Boston, MA 02115 USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2024年 / 131卷 / 01期
关键词
STATIC ARTICULATION ACCURACY;
D O I
10.1016/j.prosdent.2022.03.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Although average values and facebow records have been incorporated into prosthetic dentistry with much success, little is known about how using 3D facial scans for mounting compare with traditional mounting methods. Purpose. The purpose of this pilot clinical study was to determine differences in measurements among casts mounted virtually by using the average values of the Bonwill triangle and the Balkwill angle, casts mounted by using facebow records, and casts mounted from 3D facial scans. Material and methods. Intraoral digital scans were obtained from each participant (n=10) and 3D printed in resin. For the facebow preservation group (FPG), a facebow record was used to mount the resin casts on a semiadjustable articulator. A desktop scanner was used to digitize this mounting while preserving the facebow record. The average mounting group (AMG) consisted of intraoral digital scans that were mounted virtually by using the concepts of the Bonwill triangle and the Balkwill angle. For the facial scan group (FSG), the participants' digitized casts were superimposed on the facial scans by using a target system. The Bergstrom point and the glabella were used to mount these casts and their associated facial scans in the digital environment. This study used the FPG as the group to compare with the other mounting techniques because of its wide acceptance in restorative dentistry. These virtual mountings were completed in a computer-aided design software program, and the distance from right and left condylar elements to the incisal embrasure between mandibular central incisors, distance from left mandibular first molar to left condylar element and from right mandibular first molar to right condylar element, and anterior and posterior recordings at 0 mm, 3 mm, and 5 mm of vertical dimension increase were recorded. A Kruskal-Wallis 1-way analysis of variance was performed (a=.05). The Mann-Whitney U test was performed to evaluate differences in measured values among groups, and multiple comparisons were adjusted by using Bonferroni correction. Results. All anterior and posterior measurements to the condylar elements of the virtual articulator were found to be significantly different (P<.05). Both anterior and posterior condylar measurements between the FPG and the AMG were found to be significantly different (P<.05), while comparisons between the FPG and the FSG were found not to be significantly different (P>.05). All changes in vertical dimension were found not tobe significantly different with respect to both anterior and posterior measurements (P>.05). Conclusions. When used to virtually mount dental casts, 3D facial scanners performed similarly to traditional facebow records. (J Prosthet Dent 2024;131:136-43)
引用
收藏
页码:136 / 143
页数:8
相关论文
共 31 条
  • [21] Comparison of automated post-processing techniques for measurement of body surface area from 3D photonic scans
    Chiu, Chuang-Yuan
    Pease, David L.
    Fawkner, Samantha
    Dunn, Marcus
    Sanders, Ross H.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2019, 7 (02): : 229 - 236
  • [22] Automatic removal of soft tissue from 3D dental photo scans; an important step in automating future forensic odontology identification
    Petersen, Anika Kofod
    Forgie, Andrew
    Bindslev, Dorthe Arenholt
    Villesen, Palle
    Larsen, Line Staun
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [23] Digital workflow: In vitro accuracy of 3D printed casts generated from complete-arch digital implant scans (vol 124, pg 589, 2020)
    Papaspyridakos, P.
    Chen, Y-W
    Alshawaf, B.
    Kang, K.
    Finkelman, M.
    Chronopoulos, V
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (06):
  • [24] The reliability and validity of measurements of human dental casts made by an intra-oral 3D scanner, with conventional hand-held digital callipers as the comparison measure
    Rajshekar, Mithun
    Julian, Roberta
    Williams, Anne-Marie
    Tennant, Marc
    Forrest, Alex
    Walsh, Laurence J.
    Wilson, Gary
    Blizzard, Leigh
    FORENSIC SCIENCE INTERNATIONAL, 2017, 278 : 198 - 204
  • [25] Comparison of the Effective Radiation Dose in the Region of the Facial Skull Between Multidetector CT, Dental Conebeam CT and Intraoperative 3D C-Arms
    Pietzka, Sebastian
    Grieser, Anne
    Winter, Karsten
    Schramm, Alexander
    Metzger, Marc
    Semper-Hogg, Wiebke
    Grunert, Michael
    Ebeling, Marcel
    Sakkas, Andreas
    Wilde, Frank
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2023,
  • [26] Comparison of SUV values obtained from PET/CT Imaging done on 2D and 3D modes in oncological cases
    Kocabas, B.
    Yapar, A. F.
    Reyhan, M.
    Aktas, A.
    Aydin, M.
    Gencoglu, E. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S354 - S354
  • [27] The impact of base design and restoration type on the resin consumption, trueness, and dimensional stability of dental casts additively manufactured from liquid crystal display 3D printers
    Tseng, Chih-Wei
    Lin, Wei-Shao
    Sahrir, Citra Dewi
    Lin, Wei-Chun
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [28] 3D acquisition and management of dental casts. New frontiers from the laser scanning: A useful tool for the evaluation of the neonatal therapy with the obturator device in cleft palate
    Morselli, PG
    Achilli, V
    Salemi, G
    Russo, A
    Marini, I
    PROCEEDINGS OF THE 7TH EUROPEAN CRANIOFACIAL CONGRESS, 2003, : 107 - 112
  • [29] Comparison of conventional study model measurements and 3D digital study model measurements from laser scanned dental impressions
    Nugrahani, F.
    Jazaldi, F.
    Noerhadi, N. A. I.
    1ST PHYSICS AND TECHNOLOGIES IN MEDICINE AND DENTISTRY SYMPOSIUM, 2017, 884
  • [30] Morphometric Comparison of Clavicle Outlines from 3D Bone Scans and 2D Chest Radiographs: A Shortlisting Tool to Assist Radiographic Identification of Human Skeletons
    Stephan, Carl N.
    Amidan, Brett
    Trease, Harold
    Guyomarc'h, Pierre
    Pulsipher, Trenton
    Byrd, John E.
    JOURNAL OF FORENSIC SCIENCES, 2014, 59 (02) : 306 - 313