Complete migration of a fully covered self-expandable metallic stent after endoscopic ultrasound-guided hepaticogastrostomy: A case report

被引:0
|
作者
Tomooka, Fumimasa [1 ]
Kitagawa, Koh [1 ,3 ]
Mitoro, Akira [2 ]
Motokawa, Yuki [1 ]
Takami, Masayoshi [1 ]
Asada, Shohei [1 ]
Nishimura, Norihisa [1 ]
Ozutsumi, Takahiro [2 ]
Fujinaga, Yukihisa [1 ]
Yoshiji, Hitoshi [1 ]
机构
[1] Nara Med Univ, Dept Gastroenterol, Nara, Japan
[2] Nara Med Univ, Div Endoscopy, Nara, Japan
[3] Nara Med Univ, Dept Gastroenterol, 840 Shijou Cho, Kashihara, Nara 6348522, Japan
来源
关键词
Adverse events; endoscopic ultrasound-guided hepaticogastrostomy; reintervention; stent migration;
D O I
10.1177/2050313X231200290
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A male patient underwent gastrojejunal bypass surgery in 2017. In 2020, he was referred to our hospital for suspected obstructive jaundice. Subsequently, he was diagnosed with cholangiocarcinoma, and endoscopic retrograde cholangiopancreatography was attempted via balloon-assisted enteroscopy. However, the endoscope did not reach the duodenal papilla owing to the abdomen-small intestine adhesion. Therefore, endoscopic ultrasound-guided hepaticogastrostomy was performed using a dedicated plastic stent. After stent placement, obstructive jaundice and cholangitis promptly improved. However, we replaced the plastic stent with a fully covered self-expandable metal stent because stent occlusions occurred frequently. Two months after fully covered self-expandable metal stent placement, the patient developed cholangitis again. Notably, during the endoscopic procedure, the stent was found to be completely migrated. Nevertheless, the fistula was still open, and the patient was successfully retreated with the maintained fistula of endoscopic ultrasound-guided hepaticogastrostomy.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] A Bolt Method of Treating the Stent Migration After Endoscopic Ultrasound-Guided Hepaticogastrostomy
    Liu, Wen
    Wang, Sheng
    Guo, Jintao
    Liu, Xiang
    Ge, Nan
    Wang, Guoxin
    Sun, Siyu
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2021, 116 (02): : 238 - 238
  • [42] Transgastric reintervention for self-expandable metallic stent dysfunction following endoscopic ultrasonography-guided hepaticogastrostomy
    Ban, Tesshin
    Kawakami, Hiroshi
    Kubota, Yoshimasa
    DIGESTIVE ENDOSCOPY, 2018, 30 (05) : 682 - 683
  • [43] Salvage therapy of bleeding esophageal tumor by fully covered self-expandable metallic stent: A case report
    Bilal, Sundus
    Saeed, Saad Muhammad
    Siddique, Muhammad Zeeshan
    Saqib, Muhammad
    Mehmood, Shafqat
    Yusuf, Muhammed Aasim
    SAGE OPEN MEDICAL CASE REPORTS, 2021, 9
  • [44] Endoscopic ultrasound-guided insertion of a large diameter fully covered self-expandable metallic stent as rescue therapy for recurrent infected walled off pancreatic necrosis after surgical necrosectomy
    Ang, Tiing Leong
    Kwek, Andrew Boon Eu
    Fock, Kwong Ming
    Teo, Eng Kiong
    ENDOSCOPIC ULTRASOUND, 2014, 3 (04) : 245 - 248
  • [45] Tissue ingrowth in a fully covered self-expandable metallic stent (with videos)
    Jaganmohan, Sathya
    Raju, Gottumukkala S.
    GASTROINTESTINAL ENDOSCOPY, 2008, 68 (03) : 602 - 604
  • [46] Re-intervention for recurrent biliary obstruction after endoscopic ultrasound hepaticogastrostomy with partially covered self-expandable metal stent
    Maehara, Kosuke
    Hijioka, Susumu
    Wu, Shih Yea Sylvia
    Ohba, Akihiro
    Sakamoto, Yasunari
    Okusaka, Takuji
    Saito, Yutaka
    ENDOSCOPY, 2019, 51 (10) : E297 - E298
  • [47] Endoscopic ultrasound-guided pelvic abscess drainage using a dedicated, wide, flared-end, fully covered self-expandable metal stent
    Kawakami, Hiroshi
    Kuwatani, Masaki
    Kawahata, Shuhei
    Kubota, Yoshimasa
    Kubo, Kimitoshi
    Kawakubo, Kazumichi
    Sakamoto, Naoya
    ENDOSCOPY, 2015, 47 : E265 - E266
  • [48] Endoscopic clips prevent self-expandable metallic stent migration
    Kato, Hiroyuki
    Fukuchi, Minoru
    Miyazaki, Tatsuya
    Manda, Ryokuhei
    Faried, Ahmad
    Takita, Junko
    Nakajima, Masanobu
    Sohda, Makoto
    Fukai, Yasuyuki
    Masuda, Norihiro
    Tsukada, Katsuhiko
    Kuwano, Hiroyuki
    HEPATO-GASTROENTEROLOGY, 2007, 54 (77) : 1388 - 1390
  • [49] Endoscopic ultrasound-guided hepaticogastrostomy using a fully covered metallic stent with self-made multiple side holes for prevention of branch duct occlusion
    Kuraishi, Yasuhiro
    Hara, Kazuo
    Haba, Shin
    DIGESTIVE ENDOSCOPY, 2023, 35 (05) : E78 - E79
  • [50] Outcomes of partially covered self-expandable metal stents with different uncovered lengths in endoscopic ultrasound-guided hepaticogastrostomy: a Japanese retrospective study
    Okamoto, Takeshi
    Sasaki, Takashi
    Takeda, Tsuyoshi
    Hirai, Tatsuki
    Ishitsuka, Takahiro
    Yamada, Manabu
    Nakagawa, Hiroki
    Mie, Takafumi
    Furukawa, Takaaki
    Kasuga, Akiyoshi
    Ozaka, Masato
    Sasahira, Naoki
    CLINICAL ENDOSCOPY, 2024, 57 (04) : 515 - 526