Evaluation of Virtual Reality Perimetry and Standard Automated Perimetry in Normal Children

被引:14
|
作者
Groth, Sylvia L. [1 ,4 ]
Linton, Edward F. [1 ,2 ]
Brown, Eric N. [1 ]
Makadia, Frini [1 ,3 ]
Donahue, Sean P. [1 ]
机构
[1] Vanderbilt Univ, Dept Ophthalmol & Visual Sci, Med Ctr, Nashville, TN USA
[2] Univ Iowa, Dept Ophthalmol & Visual Sci, Iowa City, IA USA
[3] Wheaton Eye Clin, Wheaton, IL USA
[4] 2311 Pierce Ave, Nashville, TN 37232 USA
来源
关键词
automated perimetry; pediatrics; virtual reality perimetry; visual field; RELIABILITY; FEASIBILITY; STRATEGY; TESTS; SITA;
D O I
10.1167/tvst.12.1.6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The Olleyes VisuALL-K is a pediatric videogame-based static threshold perime-ter using a virtual reality headset. We determined normal threshold sensitivities for the 24-2 test locations using the virtual reality perimetry (VRP) and also tested patients on the Humphrey Field Analyzer (HFA). Patient satisfaction for the two instruments was compared.Methods: This exploratory study tested 50 normal pediatric participants aged 8 to 17 years on the HFA and VRP. The main outcome measure was threshold sensitivity at the 24-2 test locations for the two instruments.Results: The mean participant age was 13.0 & PLUSMN;2.6 years; 50% were female. The threshold values for VRP are reported as measured on the device and after conversion to an HFA-equivalent scale. Age-adjusted thresholds showed a mean sensitivity of 31.8 & PLUSMN; 1.1 dB (46.1 & PLUSMN; dB HFA equivalent) diminution from the maximum light intensity in the VRP and 31.0 & PLUSMN; 1.5 dB diminution from the maximum light intensity in the HFA; interparticipant variability in mean threshold sensitivity was 2.7 & PLUSMN; 0.4 dB for the VRP and 2.7 & PLUSMN; 0.6 dB for the HFA. The HFA demonstrated decreased threshold sensitivity with increasing eccen-tricity, whereas the VRP threshold did not seem to vary with eccentricity. Mild age effects on threshold sensitivity were seen in the VRP and the HFA (R2 = 0.11, P < 0.001 and R2 = 0.05, P < 0.05, respectively). The mean time to completion for VRP and HFA was 7.6 & PLUSMN; 1.5 and 5.3 & PLUSMN; 0.9 min/eye, respectively (P < 0.0001). Patient satisfaction scores favored VRP (P < 0.01) despite the longer test duration.Conclusions: The Olleyes game-based VRP and HFA can be used to map out the periph-eral vision in normal children. The VRP has a higher patient satisfaction when used in children than the HFA. The portability of the test allows it to be performed in a myriad of environments, lending a flexibility that can benefit this population. Translational Relevance: This virtual reality perimetry device provides an alternative to the Humphrey Field Analyzer for children.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] „Virtual reality perimetry“ und „home perimetry“Virtual reality perimetry and home perimetry
    Nathanael Urs Häner
    Hsin-Yang Chen
    Joel-Benjamin Lincke
    Xiao Shang
    Martin Sebastian Zinkernagel
    Jan Darius Unterlauft
    [J]. Die Ophthalmologie, 2024, 121 (7) : 586 - 591
  • [2] Virtual reality perimetry and home perimetry
    Haner, Nathanael Urs
    Chen, Hsin-Yang
    Lincke, Joel-Benjamin
    Shang, Xiao
    Zinkernagel, Martin Sebastian
    Unterlauft, Jan Darius
    [J]. OPHTHALMOLOGIE, 2024, 121 (07): : 586 - 591
  • [3] Repeatability and correlation of a virtual reality perimeter with standard automated perimetry in glaucoma patients
    Chaudhry, Anisa Fatima
    Berneshawi, Andrew Raphael
    Liu, Jocelyn
    Shue, Ann
    Chang, Dolly
    Kim, Julia
    Chang, Robert T.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [4] Preliminary Report on a Novel Virtual Reality Perimeter Compared With Standard Automated Perimetry
    Razeghinejad, Reza
    Gonzalez-Garcia, Alberto
    Myers, Jonathan S.
    Katz, L. Jay
    [J]. JOURNAL OF GLAUCOMA, 2021, 30 (01) : 17 - 23
  • [5] Accuracy and Reproducibility of Virtual Reality Perimetry in Children
    Pruett, Jaron K.
    Linton, Edward F.
    Donahue, Sean P.
    Groth, Sylvia L.
    [J]. JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2024, 61 (04) : 262 - 266
  • [6] Homonymous Hemianopia Detected by Short Wavelength Automated Perimetry in a Patient With Normal Standard Perimetry and MRI
    Malihi, Mehrdad
    Sit, Arthur J.
    [J]. JOURNAL OF GLAUCOMA, 2010, 19 (07) : 427 - 431
  • [7] Online Circular Contrast Perimetry: A Comparison to Standard Automated Perimetry
    Meyerov, Joshua
    Deng, Yuanchen
    Busija, Lazar
    Bigirimana, Deus
    Skalicky, Simon E.
    [J]. ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2023, 12 (01): : 4 - 15
  • [8] Rarebit Perimetry for Bedside Testing: Comparison With Standard Automated Perimetry
    Houston, Samuel K. Steven
    Weber, Eric D.
    Koga, Sebastian F.
    Newman, Steven A.
    [J]. JOURNAL OF NEURO-OPHTHALMOLOGY, 2010, 30 (03) : 243 - 247
  • [9] Standard automated perimetry (SAP)
    Heijl, A
    Bengtsson, B
    Patella, M
    Wild, J
    [J]. GLAUCOMA DIAGNOSIS STRUCTURE AND FUNCTION, 2004, : 83 - 92
  • [10] Frequency Doubling Technology perimetry and standard automated perimetry in migraine
    Harle, DE
    Evans, BJW
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2005, 25 (03) : 233 - 239