Analysis of the reliability of rapid diagnostic tests for varicella, including breakthrough cases

被引:1
|
作者
Higashimoto, Yuki [1 ]
Hattori, Fumihiko [2 ]
Kawamura, Yoshiki [3 ]
Kozawa, Kei [3 ]
Hamano, Aoi [1 ]
Kato, Mizuki [1 ]
Kato, Sayaka [1 ]
Hosokawa, Asuka [1 ]
Enya, Yasuko [4 ]
Ihira, Masaru [4 ]
Yoshikawa, Tetsushi [3 ]
机构
[1] Fujita Hlth Univ, Sch Med Sci, Dept Cellular & Mol Biol, 1-98 Dengakugakubo,Kutsukake Cho, Toyoake, Aichi 4701192, Japan
[2] Kariya Toyota Gen Hosp, Dept Pediat, Kariya, Aichi, Japan
[3] Fujita Hlth Univ, Dept Pediat, Sch Med, Toyoake, Aichi, Japan
[4] Fujita Hlth Univ, Dept Clin Sci Biol Monitoring, Sch Med Sci, Toyoake, Aichi, Japan
基金
日本学术振兴会;
关键词
breakthrough varicella; DermaQuick & REG; VZV; LAMP; real-time PCR; varicella zoster virus; MEDIATED ISOTHERMAL AMPLIFICATION; HERPES-SIMPLEX-VIRUS; ZOSTER-VIRUS; VACCINE EFFECTIVENESS; UNITED-STATES; INFECTION; DNA; HOSPITALIZATIONS; IMPLEMENTATION; IMMUNIZATION;
D O I
10.1002/jmv.28569
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
In the era of universal varicella vaccination, diagnosis of varicella is challenging, especially for breakthrough cases. We sought to clarify the reliability of direct varicella-zoster virus (VZV) loop-mediated isothermal amplification (LAMP) and DermaQuick & reg; VZV using the immunochromatography technique as rapid diagnostic tests for varicella. In addition, the usefulness of saliva as a sample type for direct LAMP was investigated. Among the 46 enrolled patients with suspected VZV infection, 31 patients (67.3%) were positive for the nucleic acid test based on real-time PCR from skin swab samples. Direct LAMP of skin swabs was positive in 29 (63.0%) of 46 patients. DermaQuick & reg; VZV was positive in 25 (54.3%) of 46 patients. VZV DNA was detected in only 48.4% of oral swabs with the direct LAMP method. With real-time polymerase chain reaction (PCR) as the standard for diagnosing varicella, the sensitivity and specificity of DermaQuick & reg; VZV were 80.7% and 100%, respectively. The sensitivity and specificity of direct LAMP from skin swabs were 93.6% and 100%, respectively. The sensitivity and specificity of real-time PCR for DNA extracted from oral swabs were 74.2% and 93.3%, respectively. Thus, oral swab samples are not suitable for breakthrough varicella diagnosis. Although DermaQuick & reg; VZV is considered the most convenient point-of-care test for varicella, its sensitivity and specificity were lower than those of direct VZV LAMP.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Evaluation of rapid diagnostic tests: Malaria
    Bell D.
    Peeling R.W.
    [J]. Nature Reviews Microbiology, 2006, 4 (Suppl 9) : S34 - S38
  • [32] RAPID DIAGNOSTIC-TESTS FOR CPV
    COX, J
    [J]. AUSTRALIAN VETERINARY PRACTITIONER, 1983, 13 (01): : 34 - 35
  • [33] Zika, and rapid diagnostic tests for malaria
    Godlee, Fiona
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2016, 352
  • [34] Rapid diagnostic tests for imported malaria
    Thompson, Courtney A.
    Boggild, Andrea K.
    [J]. CANADIAN MEDICAL ASSOCIATION JOURNAL, 2014, 186 (14) : E557 - E557
  • [35] Rapid diagnostic tests in the management of pneumonia
    Riccobono, Eleonora
    Bussini, Linda
    Giannella, Maddalena
    Viale, Pierluigi
    Rossolini, Gian Maria
    [J]. EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2022, 22 (01) : 49 - 60
  • [36] Rapid diagnostic tests for bacterial infections
    Marcade, G.
    [J]. IMMUNO-ANALYSE & BIOLOGIE SPECIALISEE, 2013, 28 (04): : 167 - 173
  • [37] Evaluation of rapid diagnostic tests: malaria
    Bell, David
    Peeling, Rosanna W.
    [J]. NATURE REVIEWS MICROBIOLOGY, 2006, : S34 - S40
  • [38] Rapid diagnostic tests for malaria parasites
    Moody, A
    [J]. CLINICAL MICROBIOLOGY REVIEWS, 2002, 15 (01) : 66 - +
  • [39] Assessing rapid diagnostic tests for malaria
    Bukirwa, Hasifa
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2011, (07):
  • [40] Influenza surveillance with rapid diagnostic tests
    Uyeki, TM
    Fukuda, K
    Cox, NJ
    [J]. CLINICAL INFECTIOUS DISEASES, 2002, 34 (10) : 1422 - 1422