Water Quality Sampling and Multi-Parameter Monitoring System Based on Multi-Rotor UAV Implementation

被引:2
|
作者
Zhang, Rihong [1 ]
Wang, Zhenhao [1 ]
Li, Xiaomin [1 ]
She, Zipeng [1 ]
Wang, Baoe [1 ]
机构
[1] Zhongkai Univ Agr & Engn, Coll Mech & Elect Engn, Guangzhou 510225, Peoples R China
关键词
water quality sampling; multi-parameter monitoring; unmanned aerial vehicle; path planning; layered hybrid improved PSO algorithm; RRT algorithm; CHINA; ALGORITHM; OPTIMIZATION; POLLUTION; RIVER;
D O I
10.3390/w15112129
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Water quality sampling and monitoring are fundamental to water environmental protection. The purpose of this study was to develop a water quality sampling and multi-parameter monitoring system mounted on a multi-rotor unmanned aerial vehicle (UAV). The system consisted of the UAV, water sampling and multi-parameter detection device, and path planning algorithm. The water sampling device was composed of a rotating drum, a direct current (DC) reduction motor, water suction hose, high-pressure isolation pump, sampling bottles, and microcontroller. The multi-parameter detection device consisted of sensors for potential of hydrogen (pH), turbidity, total dissolved solids (TDS), and a microcontroller. The flight path of the UAV was optimized using the proposed layered hybrid improved particle swarm optimization (LHIPSO) and rapidly-exploring random trees (RRT) obstacle avoidance path planning algorithm, in order to improve the sampling efficiency. Simulation experiments were conducted that compared the LHIPSO algorithm with the particle swarm optimization (PSO) algorithm and the dynamic adjustment (DAPSO) algorithm. The simulation results showed that the LHIPSO algorithm had improved global optimization capability and stability compared to the other algorithms, validating the effectiveness of the proposed algorithm. Field experiments were conducted at an aquaculture fish farm, and the device achieved real-time monitoring of three water quality parameters (pH, TDS, turbidity) at depths of 1 m and 2 m. A rapid analysis of three parameters (ammonia nitrogen, nitrite, dissolved oxygen) was performed in the laboratory on the collected water samples, and validated the feasibility of this study.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Research of key technologies for multi-rotor UAV automatic aerial recovery system
    Xing, Zhenlin
    Zhang, Li
    Ai, Jianliang
    [J]. ELECTRONICS LETTERS, 2022, 58 (07) : 277 - 279
  • [32] Design and Implementation of the Multi-parameter Laser Test System
    Yang, H. W.
    Shan, Y. H.
    Gao, X. M.
    [J]. PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE AND INDUSTRIAL ENGINEERING (AIIE 2015), 2015, 123 : 132 - 135
  • [33] A New Multi-parameter Monitoring system Based on Wireless Sensor Network
    Liu, Xingqiao
    Liu, Yiying
    Li, Chengchun
    Liu, Guohai
    [J]. NSWCTC 2009: INTERNATIONAL CONFERENCE ON NETWORKS SECURITY, WIRELESS COMMUNICATIONS AND TRUSTED COMPUTING, VOL 2, PROCEEDINGS, 2009, : 755 - +
  • [34] GPRS-based Remote PLC Multi-parameter Monitoring System
    Liu, Xingqiao
    Lu, Xiaosong
    Chong, Qingfeng
    [J]. ADVANCES IN MECHATRONICS AND CONTROL ENGINEERING II, PTS 1-3, 2013, 433-435 : 1192 - 1196
  • [35] Design and Development of IOT Based Multi-Parameter Patient Monitoring System
    Athira, A.
    Devika, T. D.
    Varsha, K. R.
    Bose, Sree Sanjanaa S.
    [J]. 2020 6TH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING AND COMMUNICATION SYSTEMS (ICACCS), 2020, : 862 - 866
  • [36] Multi-parameter water quality sensors for water supply systems
    Aisopou, A.
    Stoianov, I.
    Arora, A.
    O'Hare, D.
    Graham, N.
    [J]. INTEGRATING WATER SYSTEMS, 2010, : 349 - 355
  • [37] Design and implementation of atmospheric multi-parameter sensor for UAV-based aerosol distribution detection
    Yu, Fangjie
    Liu, Yunfei
    Fan, Longqing
    Li, Linhua
    Han, Yong
    Chen, Ge
    [J]. SENSOR REVIEW, 2017, 37 (02) : 196 - 210
  • [38] Multi-Parameter Intelligent Monitoring System for Cold Store
    Zhang, Kaisheng
    Zeng, Yuan
    [J]. PROCEEDINGS OF 2010 3RD IEEE INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND INFORMATION TECHNOLOGY (ICCSIT 2010), VOL 6, 2010, : 516 - 519
  • [39] System for Multi Parameter Water Quality Monitoring Based on NB-IoT
    Lee, Chang-Won
    Jeong, Hoon
    Ryu, Jae-Hong
    Park, Juderk
    Choi, Byeong-Cheol
    [J]. 12TH INTERNATIONAL CONFERENCE ON ICT CONVERGENCE (ICTC 2021): BEYOND THE PANDEMIC ERA WITH ICT CONVERGENCE INNOVATION, 2021, : 759 - 761
  • [40] Water Quality Parameter Monitoring System in Multi-Region Based on IOT
    Li, Hui
    Li, Jing
    [J]. PROCEEDINGS OF THE 2017 7TH INTERNATIONAL CONFERENCE ON EDUCATION, MANAGEMENT, COMPUTER AND SOCIETY (EMCS 2017), 2017, 61 : 271 - 274