Comparative Study of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock Abutments

被引:9
|
作者
Tartea, Daniel Adrian [1 ]
Ionescu, Mihaela [2 ]
Manolea, Horia Octavian [3 ]
Mercut, Veronica [4 ]
Obadan, Eugenia [3 ]
Amarascu, Marina Olimpia [5 ]
Marasescu, Petre Costin [6 ]
Daguci, Luminita
Popescu, Sanda Mihaela [1 ]
机构
[1] Univ Med & Pharm Craiova, Dept Oral Rehabil, Craiova 200349, Romania
[2] Univ Med & Pharm Craiova, Dept Med Informat & Biostat, Craiova 200349, Romania
[3] Univ Med & Pharm Craiova, Dept Dent Mat, Craiova 200349, Romania
[4] Univ Med & Pharm Craiova, Dept Dent Prosthet, Craiova 200349, Romania
[5] Univ Med & Pharm Craiova, Dept Dent Morphol, Craiova 200349, Romania
[6] Univ Med & Pharm Craiova, Dept Dent Technol, Craiova 200349, Romania
关键词
dental prostheses; CAD; CAM; dental technology; evaluation methods; CAD/CAM ABUTMENTS; ANTERIOR REGIONS; STABILITY;
D O I
10.3390/jcm12062128
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The implementation of CAD-CAM systems in dentistry has significantly influenced the evolution of dental implantology and implant-supported prosthetics within the past three decades. Implant-supported prostheses are comfortable and aesthetic. The prosthetic abutment has also faced a rapid design evolution, from the individualization of standard stock abutments offered by various manufacturers to a modern customization process using CAD-CAM technology. This paper presents a comparative study between 20 dental custom CAD-CAM implant abutments and 20 dental implant stock abutments, based on a set of measurements performed on the digital casts obtained from 24 cases of prosthetic rehabilitation on implants. The statistical analysis (Mann-Whitney U test) revealed significant differences between these two types of abutments: the incisal margin line diameter dimensions for custom abutments were significantly improved compared to standard abutments at the cervical level (U = 343.00, z = 3.868, p < 0.0005) and the incisal/occlusal level (U = 352.00, z = 4.112, p < 0.0005), while the inclination angle of the custom abutments relative to the 0-axis was significantly smaller than that of standard abutments (U = 115.50, z = -2.286, p = 0.022). The use of custom abutments leads to an increase in the final size of the abutment, an improvement in the retention of the prosthetic work, and reduces the angulation of the abutment in relation to the implant axis, thus decreasing the risk of unscrewing or fracturing the dental screw.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Used dental implant healing abutments elicit immune responses: A comparative analysis of detoxification strategies
    Narvekar, Aniruddh
    Valverde Estepa, Araceli
    Naqvi, Afsar
    Nares, Salvador
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (06) : 730 - 738
  • [42] CEREC labside implant restorations:: Custom made abutments
    Zoellner, Axel
    Benthaus, Kati
    STATE OF THE ART OF CAD/CAM RESTORATIONS: 20 YEARS OF CEREC, 2006, : 163 - +
  • [43] DENTAL CAD-CAM SYSTEMS
    REKOW, ED
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1991, 122 (13): : 42 - 48
  • [44] Comparative Analysis of Screw Loosening With Prefabricated Abutments and Customized CAD/CAM Abutments
    Paek, Janghyun
    Woo, Yi-Hyung
    Kim, Hyeong-Seob
    Pae, Ahran
    Noh, Kwantae
    Lee, Hyeonjong
    Kwon, Kung-Rock
    IMPLANT DENTISTRY, 2016, 25 (06) : 770 - 774
  • [45] Fracture Load of Monolithic CAD/CAM Ceramic Crowns Placed on Different Implant Abutments
    Meneghetti, Priscila Ceolin
    Pittas do Canto, Paulo Eduardo
    Spohr, Ana Maria
    Burnett Junior, Luiz Henrique
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (06) : 1217 - 1222
  • [46] CAD/CAM dental systems in implant dentistry: Update
    Fuster-Torres, Ma Angeles
    Albalat-Estela, Salvador
    Alcaniz-Raya, Mariano
    Penarrocha-Diago, Maria
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2009, 14 (03): : E141 - E145
  • [47] Effect of titanium and zirconia dental implant abutments on a cultivable polymicrobial saliva community
    de Avila, Erica D.
    Vergani, Carlos Eduardo
    Mollo Junior, Francisco A.
    Jafelicci Junior, Miguel
    Shi, Wenyuan
    Lux, Renate
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (04): : 481 - 487
  • [48] The Effects of Dental Hygiene Instruments on Streptococcus sanguinis Adhesion to Titanium Implant Abutments
    Nasir, Nadzirah Muhamad
    Taib, Haslina
    Nawi, Mohamad Arif Awang
    Hassan, Akram
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [49] Histologic Evaluation of Soft Tissues around Dental Implant Abutments: A Narrative Review
    Cinquini, Chiara
    Marchio, Vincenzo
    Di Donna, Edouard
    Alfonsi, Fortunato
    Derchi, Giacomo
    Nisi, Marco
    Barone, Antonio
    MATERIALS, 2022, 15 (11)
  • [50] DESIGN CONCEPTS OF A REMOVABLE PARTIAL DENTAL PROSTHESIS WITH IMPLANT-SUPPORTED ABUTMENTS
    Yeung, Stephanie
    Chee, Winston W. L.
    Torbati, Arman
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (02): : 99 - 103