Contrast-enhanced Mammography-guided Biopsy: Initial Trial and Experience

被引:10
|
作者
Kowalski, Aneta [1 ]
Arefan, Dooman [1 ]
Ganott, Marie A. [1 ]
Harnist, Kimberly [1 ]
Kelly, Amy E. [1 ]
Lu, Amy [1 ]
Nair, Bronwyn E. [1 ]
Sumkin, Jules H. [1 ]
Vargo, Adrienne [1 ]
Berg, Wendie A. [1 ]
Zuley, Margarita L. [1 ]
机构
[1] Univ Pittsburgh, Dept Radiol, Magee Womens Hosp, Med Ctr, Pittsburgh, PA 15260 USA
关键词
contrast-enhanced mammography; breast biopsy; CEM biopsy; SPECTRAL MAMMOGRAPHY; DIAGNOSTIC PERFORMANCE; PATIENT PREFERENCES; DIGITAL MAMMOGRAPHY; MRI; WOMEN; CESM;
D O I
10.1093/jbi/wbac096
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective Evaluate lesion visibility and radiologist confidence during contrast-enhanced mammography (CEM)-guided biopsy. Methods Women with BI-RADS >= 4A enhancing breast lesions were prospectively recruited for 9-g vacuum-assisted CEM-guided biopsy. Breast density, background parenchymal enhancement (BPE), lesion characteristics (enhancement and conspicuity), radiologist confidence (scale 1-5), and acquisition times were collected. Signal intensities in specimens were analyzed. Patient surveys were collected. Results A cohort of 28 women aged 40-81 years (average 57) had 28 enhancing lesions (7/28, 25% malignant). Breast tissue was scattered (10/28, 36%) or heterogeneously dense (18/28, 64%) with minimal (12/28, 43%), mild (7/28, 25%), or moderate (9/28, 32%) BPE on CEM. Twelve non-mass enhancements, 11 masses, 3 architectural distortions, and 2 calcification groups demonstrated weak (12/28, 43%), moderate (14/28, 50%), or strong (2/28, 7%) enhancement. Specimen radiography demonstrated lesion enhancement in 27/28 (96%). Radiologists reported complete lesion removal on specimen radiography in 8/28 (29%). Average time from contrast injection to specimen radiography was 18 minutes (SD = 5) and, to post-procedure mammogram (PPM), 34 minutes (SD = 10). Contrast-enhanced mammography PPM was performed in 27/28 cases; 13/19 (68%) of incompletely removed lesions on specimen radiography showed residual enhancement; 6/19 (32%) did not. Across all time points, average confidence was 2.2 (SD = 1.2). Signal intensities of enhancing lesions were similar to iodine. Patients had an overall positive assessment. Conclusion Lesion enhancement persisted through PPM and was visible on low energy specimen radiography, with an average "confident" score. Contrast-enhanced mammography-guided breast biopsy is easily implemented clinically. Its availability will encourage adoption of CEM.
引用
收藏
页码:148 / 158
页数:11
相关论文
共 50 条
  • [11] Breast radiation dose with contrast-enhanced mammography-guided biopsy: a retrospective comparison with stereotactic and tomosynthesis guidance
    Alcantara, Rodrigo
    Azcona, Javier
    Pitarch, Mireia
    Arenas, Natalia
    Castells, Xavier
    Milioni, Pablo
    Iotti, Valentina
    Besutti, Giulia
    EUROPEAN RADIOLOGY, 2025, 35 (04) : 2119 - 2129
  • [12] Breast interventional procedures: Contrast-enhanced mammography-guided biopsy and angiomammography-guided preoperative scouting of impalpable breast cancer
    Taconet, Dorothee
    Haquin, Audrey
    Maissiat, Emmanuele
    Leveugle, Juliette Pin
    Boussel, Loic
    IMAGERIE DE LA FEMME, 2023, 33 (02) : 97 - 100
  • [13] Contrast-enhanced digital mammography: Initial clinical experience
    Jong, RA
    Yaffe, MJ
    Skarpathiotakis, M
    Shumak, RS
    Danjoux, NM
    Gunesekara, A
    Plewes, DB
    RADIOLOGY, 2003, 228 (03) : 842 - 850
  • [14] A case report of breast cancer in silicone-injected breasts diagnosed by an emerging technique of contrast-enhanced mammography-guided biopsy
    Cheung, Yun-Chung
    Kuo, Wen-Lin
    Lee, Li-Yu
    Tang, Ya-Chun
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [15] Initial Attempted Contrast-Enhanced Mammography- Guided Biopsy for Suspicious Breast MRI Findings: A Single Institution's Experience
    Morris, Michael F.
    Summers, Danielle
    Welk, Leslie A.
    Harrison, Molly
    Johnston, Brian
    Rangan, Pooja
    Loving, Vilert A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2025, 224 (01)
  • [16] Contrast-enhanced ultrasound-guided biopsy of suspicious breast lesions on contrast-enhanced mammography and contrast-enhanced MRI: a case series
    Pi-Yi Huang
    Meng-Yuan Tsai
    Jer-Shyung Huang
    Pei-Ying Lin
    Chen-Pin Chou
    Journal of Medical Ultrasonics, 2023, 50 : 521 - 529
  • [17] Contrast-enhanced ultrasound-guided biopsy of suspicious breast lesions on contrast-enhanced mammography and contrast-enhanced MRI: a case series
    Huang, Pi-Yi
    Tsai, Meng-Yuan
    Huang, Jer-Shyung
    Lin, Pei-Ying
    Chou, Chen-Pin
    JOURNAL OF MEDICAL ULTRASONICS, 2023, 50 (04) : 521 - 529
  • [18] Contrast-enhanced spectral mammography: successful initial clinical institute experience
    Chalabi, Nivine Abdel Moneim
    AbuElMaati, Amal Amin
    Elsadawy, Momena Essam Ibrahim
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):
  • [19] Contrast-enhanced spectral mammography: successful initial clinical institute experience
    Nivine Abdel Moneim Chalabi
    Amal Amin AbuElMaati
    Momena Essam Ibrahim Elsadawy
    Egyptian Journal of Radiology and Nuclear Medicine, 52
  • [20] Positron emission mammography-guided breast biopsy
    Raylman, RR
    Majewski, S
    Weisenberger, AG
    Popov, V
    Wojcik, R
    Kross, B
    Schreiman, JS
    Bishop, HA
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (06) : 960 - 966