Contrast-enhanced Mammography-guided Biopsy: Initial Trial and Experience

被引:10
|
作者
Kowalski, Aneta [1 ]
Arefan, Dooman [1 ]
Ganott, Marie A. [1 ]
Harnist, Kimberly [1 ]
Kelly, Amy E. [1 ]
Lu, Amy [1 ]
Nair, Bronwyn E. [1 ]
Sumkin, Jules H. [1 ]
Vargo, Adrienne [1 ]
Berg, Wendie A. [1 ]
Zuley, Margarita L. [1 ]
机构
[1] Univ Pittsburgh, Dept Radiol, Magee Womens Hosp, Med Ctr, Pittsburgh, PA 15260 USA
关键词
contrast-enhanced mammography; breast biopsy; CEM biopsy; SPECTRAL MAMMOGRAPHY; DIAGNOSTIC PERFORMANCE; PATIENT PREFERENCES; DIGITAL MAMMOGRAPHY; MRI; WOMEN; CESM;
D O I
10.1093/jbi/wbac096
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective Evaluate lesion visibility and radiologist confidence during contrast-enhanced mammography (CEM)-guided biopsy. Methods Women with BI-RADS >= 4A enhancing breast lesions were prospectively recruited for 9-g vacuum-assisted CEM-guided biopsy. Breast density, background parenchymal enhancement (BPE), lesion characteristics (enhancement and conspicuity), radiologist confidence (scale 1-5), and acquisition times were collected. Signal intensities in specimens were analyzed. Patient surveys were collected. Results A cohort of 28 women aged 40-81 years (average 57) had 28 enhancing lesions (7/28, 25% malignant). Breast tissue was scattered (10/28, 36%) or heterogeneously dense (18/28, 64%) with minimal (12/28, 43%), mild (7/28, 25%), or moderate (9/28, 32%) BPE on CEM. Twelve non-mass enhancements, 11 masses, 3 architectural distortions, and 2 calcification groups demonstrated weak (12/28, 43%), moderate (14/28, 50%), or strong (2/28, 7%) enhancement. Specimen radiography demonstrated lesion enhancement in 27/28 (96%). Radiologists reported complete lesion removal on specimen radiography in 8/28 (29%). Average time from contrast injection to specimen radiography was 18 minutes (SD = 5) and, to post-procedure mammogram (PPM), 34 minutes (SD = 10). Contrast-enhanced mammography PPM was performed in 27/28 cases; 13/19 (68%) of incompletely removed lesions on specimen radiography showed residual enhancement; 6/19 (32%) did not. Across all time points, average confidence was 2.2 (SD = 1.2). Signal intensities of enhancing lesions were similar to iodine. Patients had an overall positive assessment. Conclusion Lesion enhancement persisted through PPM and was visible on low energy specimen radiography, with an average "confident" score. Contrast-enhanced mammography-guided breast biopsy is easily implemented clinically. Its availability will encourage adoption of CEM.
引用
收藏
页码:148 / 158
页数:11
相关论文
共 50 条
  • [1] Contrast-enhanced mammography-guided biopsy: technique and initial outcomes
    Tang, Ya-Chun
    Cheung, Yun-Chung
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (08) : 5349 - 5354
  • [2] Contrast-Enhanced Mammography-Guided Breast Biopsy: Single-Center Experience
    Kornecki, Anat
    Bhaduri, Mousumi
    Khan, Nasir
    Ben Nachum, Ilanit
    Muscedere, Giulio
    Shmuilovich, Olga
    Lynn, Kalan
    Nano, Eni
    Blyth, Lily
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 220 (06) : 826 - 827
  • [3] Contrast-enhanced mammography-guided biopsy: technical feasibility and first outcomes
    R. Alcantara
    M. Posso
    M. Pitarch
    N. Arenas
    B. Ejarque
    V. Iotti
    G. Besutti
    European Radiology, 2023, 33 : 417 - 428
  • [4] Contrast-enhanced mammography-guided biopsy: technical feasibility and first outcomes
    Alcantara, R.
    Posso, M.
    Pitarch, M.
    Arenas, N.
    Ejarque, B.
    Iotti, V
    Besutti, G.
    EUROPEAN RADIOLOGY, 2023, 33 (01) : 417 - 428
  • [5] Contrast-enhanced mammography-guided biopsy: Is it safe to be implemented in clinical practice?
    Urban, Linei Augusta Brolini Delle
    EUROPEAN RADIOLOGY, 2025, 35 (04) : 2116 - 2118
  • [6] Contrast-Enhanced Mammography-Guided Biopsy: Preliminary Results of a Single-Center Retrospective Experience
    Sammarra, Matteo
    Piccolo, Claudia Lucia
    Sarli, Marina
    Stefanucci, Rita
    Tommasiello, Manuela
    Orsaria, Paolo
    Altomare, Vittorio
    Zobel, Bruno Beomonte
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (04)
  • [7] Contrast-enhanced mammography-guided biopsy: why, when, and where we need it
    Simone Schiaffino
    Andrea Cozzi
    European Radiology, 2023, 33 : 414 - 416
  • [8] Contrast-enhanced mammography-guided biopsy: why, when, and where we need it
    Schiaffino, Simone
    Cozzi, Andrea
    EUROPEAN RADIOLOGY, 2023, 33 (01) : 414 - 416
  • [9] Sequential Contrast Media Injections for Multisite and Same-Day Contrast-Enhanced Mammography-Guided Biopsy
    Morris, Michael F.
    Welk, Leslie A.
    Harrison, Molly
    Summers, Danielle
    Loving, Vilert A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 223 (02)
  • [10] Stereotactic biopsy with contrast-enhanced mammography: the initial Australian experience
    Layden, Natalie
    Sesnan, Genevieve
    Kessell, Meredith
    Hardie, Mireille
    Taylor, Donna
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2024, 68 (04) : 393 - 400