Experimental and numerical study on weld strengths of built-up steel box columns

被引:3
|
作者
Tajik, Nima [1 ]
Mirghaderi, Seyed Rasoul [1 ]
Asghari, Abazar [1 ]
Hamidia, Mohammadjavad [2 ]
机构
[1] Univ Tehran, Coll Engn, Sch Civil Engn, Tehran, Iran
[2] Shahid Beheshti Univ, Fac Civil Water & Environm Engn, Tehran, Iran
关键词
Steel built-up box column; Fillet weld; Groove weld; Panel zone; DIC; Experimental investigation; SEISMIC PERFORMANCE; CONNECTION PERFORMANCE; MOMENT CONNECTIONS; CAPACITY; BEHAVIOR; DESIGN; SECTION; BEAMS;
D O I
10.1016/j.jcsr.2023.108362
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates the demands generated in the panel zone of welded steel built-up box columns with fillet and complete joint penetration (CJP) groove welds, which are mainly used as columns in steel moment-resisting frames. The motivation for this study stems from the a 360-16 specification for structural steel building, which requires the joining of flange and web plates of box columns with CJP groove welds within a zone extending 12 in. above the upper beam flange and 12 in. below the lower beam flange in special and intermediate steel moment frames. Laboratory experiments have been conducted to examine the strength of these welds under pure shear forces. For this purpose, two laboratory specimens, one with fillet welds and the other with CJP groove welds, have been designed, and the strength of these welds were equal to each other in pure shear force conditions. The fillet weld specimen has resisted up to 1670 kN in the pure shear test, and the CJP groove weld has resisted up to 1520 kN. The entire loading process of each specimen was characterized by employing the digital image correlation (DIC) technique, which enabled the extraction of strain values throughout. Numerical modeling is validated in Abaqus software using experimental results, with comprehensive analyses on force displacement diagrams and rupture. The outcomes of the tests conducted have shown that the demands generated in the panel zone of the built-up steel box welded sections are satisfactorily tolerated by both fillet and CJP groove welds.Research significance: The significance of this study can be elaborated in multiple aspects. Firstly, it introduces an innovative test setup meticulously designed to replicate the behavior of welded built-up box columns with corner joints to steel plates. This advanced experimental arrangement not only facilitates the current study, but also serves as a versatile tool for conducting forthcoming experiments, allowing for meaningful comparisons and further exploration of diverse phenomena within the field. Secondly, the deliberate imposition of uniform demands on both types of welds during the study enables a comprehensive examination of their behavioral characteristics. This comprehensive analysis contributes to a more profound comprehension of welds performance under identical conditions, thereby enhancing our knowledge within the field. Finally, the research outcome, which reveals that fillet welds exhibit almost identical load-bearing capacity in comparison to CJP groove welds, bears substantial practical significance for the construction industry. This finding has the potential to instigate more cost-effective and efficient welding practices, which are paramount for maintaining the structural integrity of steel structures.In summary, this study makes a noteworthy contribution to the scientific community by presenting an innovative test setup, deepening the knowledge of weld performance, and suggesting practical enhancements in welding methodologies. These collective contributions serve to elevate the field of structural engineering, promoting advancements in construction practices.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Numerical Study on the Structural Integrity of Built-up Cold-Formed Steel Battened Columns
    Dar, M. Adil
    Sahoo, Dipti Ranjan
    Jain, Arvind K.
    STRUCTURAL INTEGRITY ASSESSMENT, ICONS 2018, 2020, : 815 - 823
  • [22] Behaviour of laced built-up cold-formed steel columns: Experimental investigation and numerical validation
    Dar, M. Adil
    Sahoo, Dipti Ranjan
    Pulikkal, Sunil
    Jain, Arvind K.
    THIN-WALLED STRUCTURES, 2018, 132 : 398 - 409
  • [23] Numerical Studies on CFRP Strengthened Cold formed Steel built-up Columns
    Chakravarthy, Nahushananda H. G.
    Jahnavi, S. J.
    Naganathan, Sivakumar
    INTERNATIONAL JOURNAL OF SUSTAINABLE CONSTRUCTION ENGINEERING AND TECHNOLOGY, 2022, 13 (01): : 264 - 272
  • [24] EXPERIMENTAL INVESTIGATION OF BUILT-UP COLUMNS.
    Guhamajumder, S.C.
    Das, P.K.
    Journal of the Institution of Engineers (India): Civil Engineering Division, 1972, 53 (Pt CI 1): : 1 - 3
  • [25] Experimental and numerical investigations on the axial capacity of cold-formed steel built-up box sections
    Roy, Krishanu
    Ting, Tina Chui Huon
    Lau, Hieng Ho
    Lim, James B. P.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 160 : 411 - 427
  • [26] Experimental analysis on behavior of cold-formed steel box built-up section columns under axial compression
    Nie, Shaofeng
    Zhou, Tianhua
    Yuan, Taotao
    Gao, Tingting
    Wu, Hanheng
    Tumu Jianzhu yu Huanjing Gongcheng/Journal of Civil, Architectural and Environmental Engineering, 2012, 34 (04): : 46 - 52
  • [27] Experimental and numerical investigation on cold-formed steel built-up section pin-ended columns
    Li, Qiu-Yun
    Young, Ben
    THIN-WALLED STRUCTURES, 2022, 170
  • [28] Investigation of built-up box columns composed of four cold-formed steel channels
    Nie, Shaofeng
    Eatherton, Matthew R.
    Han, Yong
    Zhou, Tianhua
    Wu, Hanheng
    Li, Jiang
    THIN-WALLED STRUCTURES, 2022, 175
  • [29] Simplified design method of cold-formed steel columns with built-up box sections
    Zhou, Xuhong
    Xiang, Yi
    Shi, Yu
    Xu, Lei
    Zou, Yuxuan
    ENGINEERING STRUCTURES, 2021, 228
  • [30] Stainless steel built-up section stub columns: Testing, numerical modelling and design
    Jiang, Ke
    Zhao, Ou
    THIN-WALLED STRUCTURES, 2023, 191