Electrical Impedance Tomography: From the Traditional Design to the Novel Frontier of Wearables

被引:32
|
作者
Pennati, Francesca [1 ]
Angelucci, Alessandra [1 ]
Morelli, Letizia [1 ]
Bardini, Susanna [1 ]
Barzanti, Elena [1 ]
Cavallini, Federico [1 ]
Conelli, Antonello [1 ]
Di Federico, Gaia [1 ]
Paganelli, Chiara [1 ]
Aliverti, Andrea [1 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, I-20133 Milan, Italy
关键词
electrical impedance tomography; wearable; imaging; REGIONAL LUNG VENTILATION; RECONSTRUCTION ALGORITHMS; DIELECTRIC-PROPERTIES; SYSTEM; EIT; BIOIMPEDANCE; BOUNDARY; BRAIN; ELECTRODES; BELT;
D O I
10.3390/s23031182
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrical impedance tomography (EIT) is a medical imaging technique based on the injection of a current or voltage pattern through electrodes on the skin of the patient, and on the reconstruction of the internal conductivity distribution from the voltages collected by the electrodes. Compared to other imaging techniques, EIT shows significant advantages: it does not use ionizing radiation, is non-invasive and is characterized by high temporal resolution. Moreover, its low cost and high portability make it suitable for real-time, bedside monitoring. However, EIT is also characterized by some technical limitations that cause poor spatial resolution. The possibility to design wearable devices based on EIT has recently given a boost to this technology. In this paper we reviewed EIT physical principles, hardware design and major clinical applications, from the classical to a wearable setup. A wireless and wearable EIT system seems a promising frontier of this technology, as it can both facilitate making clinical measurements and open novel scenarios to EIT systems, such as home monitoring.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] An Algorithm Design for Electrical Impedance Tomography Based on Levenberg Method
    Zhou, Mingyong
    Lu, Xin
    RECENT DEVELOPMENTS IN INTELLIGENT SYSTEMS AND INTERACTIVE APPLICATIONS (IISA2016), 2017, 541 : 110 - 113
  • [22] Design of a Superconducting Magnet for Lorentz Force Electrical Impedance Tomography
    Shen, Boyang
    Fu, Lin
    Geng, Jianzhao
    Zhang, Heng
    Zhang, Xiuchang
    Zhong, Zhaoyang
    Huang, Zhen
    Coombs, T. A.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (03)
  • [23] DESIGN AND IMPLEMENTATION OF PRECISE HARDWARE FOR ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT)
    Khalighi, M.
    Vahdat, B. Vosoughi
    Mortazavi, M.
    Mikaeili, M.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF ELECTRICAL ENGINEERING, 2014, 38 (E1) : 1 - 20
  • [24] A Low Noise Power Design for Electrical Impedance Tomography System
    Guo, Yanyan
    Chen, Xiaoyan
    Yang, Yongzheng
    APPLIED MECHANICS, MATERIALS AND MANUFACTURING IV, 2014, 670-671 : 1159 - 1162
  • [25] The design of acquisition hardware system based on electrical impedance tomography
    Xu, GZ
    Yu, Q
    Liu, ZH
    Xing, QG
    Zhang, Q
    Yan, WL
    APPLIED ELECTROMAGNETICS (III), 2001, 10 : 471 - 474
  • [26] Design and implementation of a high frequency electrical impedance tomography system
    Halter, R
    Hartov, A
    Paulsen, KD
    PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) : 379 - 390
  • [27] Current approaches to analogue instrumentation design in electrical impedance tomography
    Boone, KG
    Holder, DS
    PHYSIOLOGICAL MEASUREMENT, 1996, 17 (04) : 229 - 247
  • [28] Electrical impedance tomography system: an open access circuit design
    Soleimani, Manuchehr
    BIOMEDICAL ENGINEERING ONLINE, 2006, 5 (1)
  • [29] A Discussion on the Algorithm Design of Electrical Impedance Tomography for Biomedical Applications
    Zhou, Mingyong
    Zhu, Hongyu
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SENSING AND IMAGING, 2018, 2019, 606 : 163 - 171
  • [30] Optimum design of electrode structure and parameters in electrical impedance tomography
    Yan, W
    Hong, S
    Chaoshi, R
    PHYSIOLOGICAL MEASUREMENT, 2006, 27 (03) : 291 - 306