Synthetic PET via Domain Translation of 3-D MRI

被引:0
|
作者
Rajagopal, Abhejit [1 ]
Natsuaki, Yutaka [2 ]
Wangerin, Kristen [3 ]
Hamdi, Mahdjoub [4 ]
An, Hongyu [4 ]
Sunderland, John J. [5 ]
Laforest, Richard [4 ]
Kinahan, Paul E. [6 ]
Larson, Peder E. Z. [1 ]
Hope, Thomas A. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94158 USA
[2] Univ New Mexico, Dept Radiat Oncol, Albuquerque, NM 87131 USA
[3] GE Healthcare, Waukesha, WI 53188 USA
[4] Washington Univ St Louis, Dept Radiol, St Louis, MO 63130 USA
[5] Univ Iowa, Dept Radiol, Iowa City, IA 98195 USA
[6] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
Magnetic resonance imaging; Positron emission tomography; Image reconstruction; Attenuation; Three-dimensional displays; Phantoms; Lesions; Digital phantoms; full-convolutional neural networks; PET/MRI qualification; standardized uptake value (SUV) quantification; ATTENUATION CORRECTION; SIMULATION; NOISE; CT; IMAGES; TIME;
D O I
10.1109/TRPMS.2022.3223275
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Historically, patient datasets have been used to develop and validate various reconstruction algorithms for PET/MRI and PET/CT. To enable such algorithm development, without the need for acquiring hundreds of patient exams, in this article we demonstrate a deep learning technique to generate synthetic but realistic whole-body PET sinograms from abundantly available whole-body MRI. Specifically, we use a dataset of 56 18F-FDG-PET/MRI exams to train a 3-D residual UNet to predict physiologic PET uptake from whole-body T1-weighted MRI. In training, we implemented a balanced loss function to generate realistic uptake across a large dynamic range and computed losses along tomographic lines of response to mimic the PET acquisition. The predicted PET images are forward projected to produce synthetic PET (sPET) time-of-flight (ToF) sinograms that can be used with vendor-provided PET reconstruction algorithms, including using CT-based attenuation correction (CTAC) and MR-based attenuation correction (MRAC). The resulting synthetic data recapitulates physiologic 18F-FDG uptake, e.g., high uptake localized to the brain and bladder, as well as uptake in liver, kidneys, heart, and muscle. To simulate abnormalities with high uptake, we also insert synthetic lesions. We demonstrate that this sPET data can be used interchangeably with real PET data for the PET quantification task of comparing CTAC and MRAC methods, achieving = 7.6% error in mean-SUV compared to using real data. These results together show that the proposed sPET data pipeline can be reasonably used for development, evaluation, and validation of PET/MRI reconstruction methods.
引用
下载
收藏
页码:333 / 343
页数:11
相关论文
共 50 条
  • [31] 3-D Inverse Synthetic Aperture Sonar Imaging
    Serafin, Piotr
    Okon-Fafara, Marta
    Szugajew, Marcin
    Lesnik, Czeslaw
    Kawalec, Adam
    2017 18TH INTERNATIONAL RADAR SYMPOSIUM (IRS), 2017,
  • [32] 3-D OR NOT 3-D
    SMITH, CW
    NEW SCIENTIST, 1984, 102 (1407) : 40 - 44
  • [33] 3-D BROADBAND TERAHERTZ SYNTHETIC APERTURE IMAGING
    Henry, S. C.
    Kniffin, G. P.
    Zurk, L. M.
    2012 37TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2012,
  • [34] 3-D OR NOT 3-D
    KERBEL, M
    FILM COMMENT, 1980, 16 (06) : 11 - 20
  • [35] 3-D OR NOT 3-D
    Kehr, Dave
    FILM COMMENT, 2010, 46 (01) : 60 - 67
  • [36] 3-D or not 3-D
    Powell, A
    JOM-JOURNAL OF THE MINERALS METALS & MATERIALS SOCIETY, 2002, 54 (01): : 22 - 24
  • [37] Noise characteristics of 3-D and 2-D PET images
    Pajevic, S
    Daube-Witherspoon, ME
    Bacharach, SL
    Carson, RE
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (01) : 9 - 23
  • [38] MEASUREMENT OF LV THICKENING BY 3-D MRI RECONSTRUCTION
    BEYAR, R
    SHAPIRO, EP
    WEISS, JL
    GRAVES, WH
    ROGERS, WJ
    GUIER, W
    ZERHOUNI, EA
    SOULEN, R
    WEISFELDT, ML
    CIRCULATION, 1987, 76 (04) : 427 - 427
  • [39] 3-D MRI-SPECT IMAGING IN SCHIZOPHRENIA
    PAHL, JJ
    WANG, C
    HOGUE, RE
    FITES, G
    WILSON, DA
    ALLEN, EW
    SCHIZOPHRENIA RESEARCH, 1994, 11 (02) : 168 - 169
  • [40] 3-D Brain MRI Tissue Classification on FPGAs
    Koo, Jahyun J.
    Evans, Alan C.
    Gross, Warren J.
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2009, 18 (12) : 2735 - 2746