Evaluating Fire Performance: An Experimental Comparison of Dovetail Massive Wooden Board Elements and Cross-Laminated Timber

被引:4
|
作者
Ilgin, Hueseyin Emre [1 ]
Karjalainen, Markku [1 ]
Alanen, Mika [1 ]
Malaska, Mikko [1 ]
机构
[1] Tampere Univ, Fac Built Environm, POB 600, FI-33014 Tampere, Finland
来源
FIRE-SWITZERLAND | 2023年 / 6卷 / 09期
基金
欧盟地平线“2020”;
关键词
dovetail massive wooden board elements; CLT; fire performance; char depth; charring rate; PANELS;
D O I
10.3390/fire6090352
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
The use of adhesives and metal connectors is vital in engineered wood product (EWP) composition. However, the utilization of adhesives poses sustainability and recyclability challenges due to the emission of toxic gases. Similarly, metal fasteners negatively impact the disposal, reusability, and recyclability of EWPs. An alternative solution that exclusively employs pure wood, known as dovetail massive wooden board elements (DMWBEs), eliminates the need for adhesives and metal fasteners. This paper presents an experimental comparative assessment of the fire/charring performance of DMWBEs and cross-laminated timber (CLT). Model-scale test specimens measuring 200 mm in thickness, 950 mm in width, and 950 mm in length were vertically tested according to EN 1363-1. The charring behavior of DMWBEs closely resembled that of solid timber, with only a slight increase in the charring rate. Charring primarily occurred in the third lamella layer out of five, with no observable flames or hot gases on the unexposed side. The dovetail detail effectively prevented char fall-off with the tested lamella thickness. CLT specimens exhibited a notable rise in the charring rate due to the fall-off of the first lamellae layer.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] An Experimental Comparison of Airborne Sound Insulation between Dovetail Massive Wooden Board and Cross-Laminated Timber Elements
    Ilgin, Huseyin Emre
    Lietzen, Jesse
    Karjalainen, Markku
    [J]. BUILDINGS, 2023, 13 (11)
  • [2] Experimental analysis of cross-laminated timber panels in fire
    Frangi, Andrea
    Fontana, Mario
    Hugi, Erich
    Joebstl, Robert
    [J]. FIRE SAFETY JOURNAL, 2009, 44 (08) : 1078 - 1087
  • [3] Fire behaviour of cross-laminated timber
    Klippel, Michael
    Frangi, Andrea
    [J]. BAUTECHNIK, 2016, 93 (08) : 567 - 572
  • [4] Design of Cross-Laminated Timber in Fire
    Klippel, Michael
    Schmid, Joachim
    [J]. STRUCTURAL ENGINEERING INTERNATIONAL, 2017, 27 (02) : 224 - 230
  • [5] Behaviour of Loaded Cross-Laminated Timber Wall Elements in Fire Conditions
    Joachim Schmid
    Agnese Menis
    Massimo Fragiacomo
    Isaia Clemente
    Giovanna Bochicchio
    [J]. Fire Technology, 2015, 51 : 1341 - 1370
  • [6] Behaviour of Loaded Cross-Laminated Timber Wall Elements in Fire Conditions
    Schmid, Joachim
    Menis, Agnese
    Fragiacomo, Massimo
    Clemente, Isaia
    Bochicchio, Giovanna
    [J]. FIRE TECHNOLOGY, 2015, 51 (06) : 1341 - 1370
  • [7] Structural response of cross-laminated timber compression elements exposed to fire
    Wiesner, Felix
    Randmael, Fredrik
    Wan, Wing
    Bisby, Luke
    Hadden, Rory M.
    [J]. FIRE SAFETY JOURNAL, 2017, 91 : 56 - 67
  • [8] Experimental and numerical analysis of the fire behaviour of cross-laminated timber panels
    Frangi, Andrea
    Fontana, Mario
    Bochicchio, Giovanna
    [J]. BAUPHYSIK, 2007, 29 (06) : 387 - 397
  • [9] Thermal performance of cross-laminated timber (CLT) and cross-laminated bamboo and timber (CLBT) panels
    Shan, Bo
    Chen, Bozhang
    Wen, Jie
    Xiao, Yan
    [J]. ARCHITECTURAL ENGINEERING AND DESIGN MANAGEMENT, 2023, 19 (05) : 511 - 530
  • [10] Experimental verification of design procedure for elements from cross-laminated timber
    Buka-Vaivade, Karina
    Serdjuks, Dmitrijs
    Goremikins, Vadims
    Vilguts, Aivars
    Pakrastins, Leonids
    [J]. MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, 2017, 172 : 1212 - 1219