Experimental investigation on characteristics of Multiple-Loops coupled natural circulation system

被引:4
|
作者
Wang, Chang [1 ]
Li, Xiaohui [1 ]
Chen, Jiaming [1 ]
Wang, Guanghuai [1 ]
机构
[1] China Ship Dev & Design Ctr, Wuhan 430000, Peoples R China
基金
中国国家自然科学基金;
关键词
DESIGN;
D O I
10.1016/j.nucengdes.2023.112283
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The passive safety design is advantageous because it simplifies the system and brings higher safety features. Passive residual heat removal system (PRHRS) is one of the most important passive safety systems, which is designed to cool down the reactor during accidental conditions. For floating nuclear power platforms, seawater could be utilized as the final heat sink of PRHRS through multiple-loops coupled natural circulation. To study the operating characteristics and thermal hydraulic behavior of multiple-loops coupled natural circulation system, the Natural Circulation Mechanism Experimental System (NCMES) has been constructed. The station blackout accident (SBO) scenario is simulated in NCMES, which leads to the stopping of circulation pump and operation of PRHRS. Based on the experimental data, an analysis was carried out using the thermal hydraulic system code RELAP5, aiming to validate applicability and accuracy, as well as predict the operating characteristics of the experiment facility. The comprehensive analysis of experimental and calculated results shows that when it comes to the SBO scenario, the releasing residual heat and sensible heat of fluid can be removed to seawater through triple-loops coupled natural circulation; the calculated results fit the experimental data quite well and the RELAP5 code is applicable to predict operating characteristics of multiple-loops coupled natural circulation and PRHRS. As a result of self-adaptive characteristic of natural circulation, with the heating power decreasing, the response rate of natural circulation flow rate and fluid temperature is slow.
引用
收藏
页数:12
相关论文
共 50 条
  • [42] Investigation on system - Flow resistance in a natural circulation loop
    Huang, YP
    Wang, LM
    Mu, QH
    Jia, DN
    HEAT TRANSFER SCIENCE AND TECHNOLOGY 1996, 1996, : 753 - 759
  • [43] An experimental investigation of flow boiling instability in a natural circulation loop
    Chen, Xianbing
    Gao, Puzhen
    Tan, Sichao
    Yu, Zhiting
    Chen, Chong
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 117 : 1125 - 1134
  • [44] Experimental investigation of effect of height difference on natural circulation capability
    Wang, Fei
    Peng, Xin-Jian
    Yang, Zu-Mao
    Huang, Yan-Pin
    Hedongli Gongcheng/Nuclear Power Engineering, 2002, 23 (04): : 25 - 28
  • [45] EXPERIMENTAL AND ANALYTICAL INVESTIGATION OF A PWR NATURAL CIRCULATION LOOP.
    Anon
    Electric Power Research Institute (Report) EPRI NP, 1980, (1364 -SR):
  • [46] Numerical and experimental investigations of the static characteristics of a natural circulation system at nuclear heating reactor conditions
    Jiang, SY
    Yang, X
    Zhang, Y
    KERNTECHNIK, 2002, 67 (5-6) : 266 - 270
  • [47] INVESTIGATION OF STEADY-STATE CHARACTERISTICS OF NATURAL CIRCULATION LOOP
    Huang, Zheng
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 4, 2014,
  • [48] Experimental study on geysering in an open natural circulation system
    Hou X.
    Sun Z.
    Sun Q.
    Fan G.
    Lei W.
    Sun, Zhongning (sunzhongning@hrbeu.edu.cn), 1600, Editorial Board of Journal of Harbin Engineering (37): : 556 - 561
  • [49] STUDY ON THE FLOW CHARACTERISTICS FOR AN OPEN NATURAL CIRCULATION SYSTEM
    Guo, Xueqing
    Sun, Zhongning
    Wang, Jianjun
    Su, Jiqiang
    PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 2B, 2014,
  • [50] A generalized flow equation for single phase natural circulation loops obeying multiple friction laws
    Swapnalee, B. T.
    Vijayan, P. K.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (11-12) : 2618 - 2629