Prediction of Hemodynamic-Related Hemolysis in Carotid Stenosis and Aiding in Treatment Planning and Risk Stratification Using Computational Fluid Dynamics

被引:2
|
作者
Jedrzejczak, Krystian [1 ]
Orciuch, Wojciech [1 ]
Wojtas, Krzysztof [1 ]
Kozlowski, Michal [2 ]
Piasecki, Piotr [3 ]
Narloch, Jerzy [3 ]
Wierzbicki, Marek [3 ]
Makowski, Lukasz [1 ]
机构
[1] Warsaw Univ Technol, Fac Chem & Proc Engn, Warynskiego 1, PL-00645 Warsaw, Poland
[2] Med Univ Silesia, Dept Cardiol & Struct Heart Dis, Ziolowa 47, PL-40635 Katowice, Poland
[3] Natl Res Inst, Mil Inst Med, Intervent Radiol Dept, Szaserow 128, PL-04141 Warsaw, Poland
关键词
arteriosclerosis; hemolysis; blood; CFD; coronary artery; carotid artery; percutaneous coronary intervention; hemoglobin; NONHOMOGENEOUS CONSTITUTIVE MODEL; OPTICAL COHERENCE TOMOGRAPHY; NEWTONIAN BLOOD-FLOW; NANOPARTICLE CLUSTERS; MECHANICAL HEMOLYSIS; NUMERICAL-SIMULATION; COMPUTED-TOMOGRAPHY; MAGNETIC-RESONANCE; HEART-VALVE; IN-VIVO;
D O I
10.3390/biomedicines12010037
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Atherosclerosis affects human health in many ways, leading to disability or premature death due to ischemic heart disease, stroke, or limb ischemia. Poststenotic blood flow disruption may also play an essential role in artery wall impairment linked with hemolysis related to shear stress. The maximum shear stress in the atherosclerotic plaque area is the main parameter determining hemolysis risk. In our work, a 3D internal carotid artery model was built from CT scans performed on patients qualified for percutaneous angioplasty due to its symptomatic stenosis. The obtained stenosis geometries were used to conduct a series of computer simulations to identify critical parameters corresponding to the increase in shear stress in the arteries. Stenosis shape parameters responsible for the increase in shear stress were determined. The effect of changes in the carotid artery size, length, and degree of narrowing on the change in maximum shear stress was demonstrated. Then, a correlation for the quick initial diagnosis of atherosclerotic stenoses regarding the risk of hemolysis was developed. The developed relationship for rapid hemolysis risk assessment uses information from typical non-invasive tests for treated patients. Practical guidelines have been developed regarding which stenosis shape parameters pose a risk of hemolysis, which may be adapted in medical practice.
引用
收藏
页数:20
相关论文
共 25 条
  • [1] Examination of hemodynamic environments of carotid stenosis with computational fluid dynamics
    Fukuda, Shunichi
    Shimogonya, Yuji
    FASEB JOURNAL, 2019, 33
  • [2] Hemodynamic effects of stenosis with varying severity in different segments of the carotid artery using computational fluid dynamics
    Yang, Jingxi
    Zhang, Yang
    Xue, Junzhen
    Guo, Yuxin
    Liu, Siyu
    Yao, Yixin
    Zhong, Huimin
    Quan, Anlong
    Yang, Jianbao
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [3] Unveiling hemodynamic pulsatile flow dynamics in carotid artery stenosis: Insights from computational fluid dynamics
    Kaid, Noureddine
    Benyamina, Leila
    Menni, Younes
    Alkhafaji, Mohammed Ayad
    Bayram, Mustafa
    Alshammari, Badr M.
    Kolsi, Lioua
    AIP ADVANCES, 2024, 14 (06)
  • [4] Hemodynamic predictors for the onset of ischemic stroke due to carotid artery stenosis using a computational fluid dynamics analysis
    Fukuda, Shunichi
    Shimogonya, Yuji
    PHYSIOLOGY, 2023, 38
  • [5] A role of hemodynamic stress in carotid stenosis; a study using computational fluid dynamic analyses
    Fukuda, Shunichi
    Shimogonya, Yuji
    FASEB JOURNAL, 2016, 30
  • [6] A role of hemodynamic stress in carotid stenosis; a study using computational fluid dynamic analyses
    Fukuda, Shunichi
    Shimogonya, Yuji
    FASEB JOURNAL, 2016, 30
  • [7] A Computational Fluid Dynamics Analysis Of Hemodynamic Differences In Patients With High Grade Asymptomatic Carotid Artery Stenosis
    Braet, Drew
    Assi, Ismael
    Dandu, Vivek
    Ranjane, Sid
    Carrera, Joseph
    Srinivasan, Ashok
    Osborne, Nicholas H.
    Burris, Nicholas S.
    Figueroa, C. A.
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2024, 44
  • [9] Prediction of shear stress-related hemolysis in centrifugal blood pumps by computational fluid dynamics
    Wang, FQ
    Li, L
    Feng, ZG
    Qian, KX
    PROGRESS IN NATURAL SCIENCE-MATERIALS INTERNATIONAL, 2005, 15 (10) : 951 - 955
  • [10] INFLUENCE OF CAROTID ARTERY STENOSIS LOCATION ON LESION PROGRESSION USING COMPUTATIONAL FLUID DYNAMICS
    Albadawi, Muhamed
    Abuouf, Yasser
    Ookawara, Shinichi
    Ahmed, Mahmoud
    PROCEEDINGS OF THE ASME 2020 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2020, VOL 5, 2020,