1190 nm Fourier domain mode locked (FDML) laser for optical coherence tomography (OCT)

被引:0
|
作者
Bashir, A. [1 ]
Lotz, S. [1 ]
Klufts, M. [1 ]
Krestnikov, I. [3 ]
Jirauschek, C. [4 ]
Huber, R. [1 ,2 ]
机构
[1] Univ Lubeck, Inst Biomed Opt, D-23562 Lubeck, Germany
[2] Med Laserzentrum Lubeck GmbH, Peter Monnik Weg 4, D-23562 Lubeck, Germany
[3] Innolume GmbH, Konrad Adenauer Allee 11, D-44263 Dortmund, Germany
[4] Tech Univ Munich, Hans Piloty Str 1, D-85748 Garching, Germany
基金
欧盟地平线“2020”;
关键词
FDML; laser; swept source; OCT; SS-OCT; LOCKING;
D O I
10.1117/12.2652884
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We demonstrate a Fourier domain mode locked (FDML) laser centered at 1190 nm with 2x410 kHz sweep repetition rate, a sweeping range of 100 nm and 2.5 mW output power. The laser is based on a quantum dot-semiconductor optical amplifier with small linewidth enhancement factor. The laser could be used as a probe laser in stimulated Raman scattering microscopy and it may be attractive for optical coherence tomography due to low water absorption and the spectral signature of lipids around 1200nm. Moreover, it is ideal to close the gap between FDML lasers at 1064 nm and 1300 nm. Combining these three lasers can enable ultrawideband sweeping to improve the axial OCT resolution down to 2 mu m.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Fourier domain functional optical coherence tomography
    Zhang, J
    Rao, B
    Chen, ZP
    SARATOV FALL MEETING 2004: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE VI, 2005, 5771 : 8 - 14
  • [42] Dispersion, coherence and noise of Fourier domain mode locked lasers
    Biedermann, Benjamin R.
    Wieser, Wolfgang
    Eigenwillig, Christoph M.
    Klein, Thomas
    Huber, Robert
    OPTICS EXPRESS, 2009, 17 (12): : 9947 - 9961
  • [43] Coherence length extension of Fourier domain mode locked lasers
    Adler, Desmond C.
    Wieser, Wolfgang
    Trepanier, Francois
    Schmitt, Joseph M.
    Huber, Robert A.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVI, 2012, 8213
  • [44] Fourier phase in Fourier-domain optical coherence tomography
    Uttam, Shikhar
    Liu, Yang
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2015, 32 (12) : 2286 - 2306
  • [45] Swept laser source at 1 μm for Fourier domain optical coherence tomography
    Zhang, Jun
    Wang, Qiang
    Rao, Bin
    Chen, Zhongping
    Hsu, Kevin
    APPLIED PHYSICS LETTERS, 2006, 89 (07)
  • [46] Blood oxygen saturation measurement in human retina by using 1060 nm Fourier Domain Optical Coherence Tomography (FD-OCT)
    Reddikumar, Maddipatla
    Bose, Kingshuk
    Poddar, Raju
    2013 Workshop on Recent Advances in Photonics (WRAP), 2013,
  • [47] Phase and frequency dynamics of Fourier domain mode locked OCT lasers
    Kelleher, B.
    Goulding, D.
    Slepneva, S.
    O'Shaughnessy, B.
    Butler, T.
    Hegarty, S. P.
    Vladimirov, A. G.
    Huyet, G.
    PHYSICS AND SIMULATION OF OPTOELECTRONIC DEVICES XXIII, 2015, 9357
  • [48] Fourier Domain Mode Locked Laser and Its Applications
    Huang, Dongmei
    Shi, Yihuan
    Li, Feng
    Wai, P. K. A.
    SENSORS, 2022, 22 (09)
  • [49] Detection of Glaucoma by Spectral Domain-scanning Laser Ophthalmoscopy/Optical Coherence Tomography (SD-SLO/OCT) and Time Domain Optical Coherence Tomography
    Cho, Jung Woo
    Sung, Kyung Rim
    Hong, Jung Taeck
    Um, Tae Woong
    Kang, Sung Yong
    Kook, Michael S.
    JOURNAL OF GLAUCOMA, 2011, 20 (01) : 15 - 20
  • [50] Dispersion compensation in Fourier domain optical coherence tomography
    Al-Saeed, Tarek A.
    Shalaby, Mohamed Y.
    Khalil, Diaa A.
    APPLIED OPTICS, 2014, 53 (29) : 6643 - 6653