Anatomical and Biomechanical Characteristics of the Anterolateral Ligament: A Descriptive Korean Cadaveric Study Using a Triaxial Accelerometer

被引:2
|
作者
Suh, Dae Keun [1 ]
Cho, Il-Yup [2 ]
Noh, Sehyun [3 ]
Yoon, Dong Joo [3 ]
Jang, Ki-Mo [4 ]
机构
[1] Sungkyunkwan Univ Sch Med, Samsung Med Ctr, Dept Orthopaed Surg, Seoul 06351, South Korea
[2] Seoul Barunsesang Hosp, Joint Ctr, Seoul 08523, South Korea
[3] Korea Univ, Coll Med, Seoul 02841, South Korea
[4] Korea Univ Coll Med, Anam Hosp, Dept Orthopaed Surg, Seoul 02841, South Korea
来源
MEDICINA-LITHUANIA | 2023年 / 59卷 / 02期
关键词
knee; anterolateral ligament; anterior cruciate ligament; rotatory instability; cadaver study; triaxial accelerometer; ANTERIOR CRUCIATE LIGAMENT; PIVOT-SHIFT PHENOMENON; FEMORAL ORIGIN; LENGTH CHANGES; KNEE; RECONSTRUCTION; ACL; TRANSLATION; INSTABILITY; PREVALENCE;
D O I
10.3390/medicina59020419
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: The anterolateral ligament (ALL) could be the potential anatomical structure responsible for rotational instability after anterior cruciate ligament (ACL) reconstruction. The purpose of this study was to investigate the anatomical and biomechanical characteristics of the ALL in Korean cadaveric knee joints. Materials and Methods: Twenty fresh-frozen cadaveric knees were dissected and tested. Femoral and tibial footprints of the ALL were recorded. Pivot shift and Lachman tests were measured with KiRA. Results: The prevalence of ALL was 100%. The average distance of the tibial footprint to the tip of the fibular head was 19.85 +/- 3.41 mm; from the tibial footprint to Gerdy's tubercle (GT) was 18.3 +/- 4.19 mm; from the femoral footprint to the lateral femoral epicondyle was 10.25 +/- 2.97 mm. ALL's footprint distance was the longest at 30 degrees of flexion (47.83 +/- 8.05 mm, p < 0.01) in a knee with intact ALL-ACL and neutral rotation. During internal rotation, the footprint distance was the longest at 30 degrees of flexion (50.05 +/- 8.88 mm, p < 0.01). Internal rotation produced a significant increase at all three angles after ACL-ALL were transected (p = 0.022), where the footprint distance was the longest at 30 degrees of flexion (52.05 +/- 7.60 mm). No significant difference was observed in KiRA measurements between intact ALL-ACL and ALL-transected knees for pivot shift and Lachman tests. However, ACL-ALL-transected knees showed significant differences compared to the intact ALL-ACL and ALL-transected knees (p < 0.01). Conclusions: The ALL was identified as a distinct ligament structure with a 100% prevalence in this cadaveric study. The ALL plays a protective role in internal rotational stability. An isolated ALL transection did not significantly affect the ALL footprint distances or functional stability tests. Therefore, the ALL is thought to act as a secondary supportive stabilizer for rotational stability of the knee joint in conjunction with the ACL.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] An anatomical and biomechanical study for the repair and reconstruction of the scapholunate interosseous ligament
    李秀忠
    ChinaMedicalAbstracts, 2005, (03) : 179 - 180
  • [42] Length Changes of the Anterolateral Ligament During Passive Knee Motion: A Human Cadaveric Study
    Zens, Martin
    Niemeyer, Philipp
    Ruhhammer, Johannes
    Bernstein, Anke
    Woias, Peter
    Mayr, Herrmann O.
    Suedkamp, Norbert P.
    Feucht, Matthias J.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2015, 43 (10): : 2545 - 2552
  • [43] Anatomical Characteristics of Extensor Hallucis Longus Tendon Variations and Its Clinical Implications: A Korean Cadaveric Study
    Park, Jeong-Hyun
    Choi, Yu-Jin
    Lee, Mijeong
    Kim, Digud
    Kwon, Hyung-Wook
    Park, Kwang-Rak
    Park, Sa-Beom
    Cho, Jaeho
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (16)
  • [44] Editorial Commentary: Knee Anterolateral Ligament Cadaveric, Biomechanical Analysis Should Include Tensioning of All Knee Dynamic Structures
    Kim, Sung-Hwan
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2021, 37 (04): : 1192 - 1193
  • [45] CORR Insights®: High Interspecimen Variability in Engagement of the Anterolateral Ligament: An In Vitro Cadaveric Study
    Aroen, Asbjorn
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2017, 475 (10) : 2445 - 2446
  • [46] Minimal influence of the anterolateral knee ligament on anterior and rotational laxity of the knee: a cadaveric study
    Jenny J.-Y.
    Puliero B.
    Schockmel G.
    Harnoist S.
    Clavert P.
    European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (5) : 955 - 958
  • [47] Rotational Laxity Control by the Anterolateral Ligament and the Lateral Meniscus Is Dependent on Knee Flexion Angle: A Cadaveric Biomechanical Study (vol 475, pg 2401, 2017)
    Lording, Timothy
    Corbo, Gillian
    Bryant, Dianne
    Burkhart, Timothy A.
    Getgood, Alan
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2017, 475 (10) : 2613 - 2613
  • [48] Biomechanical evaluation against calcaneofibular ligament repair in the Brostrom procedure: a cadaveric study
    Lee, Kyung-Tai
    Lee, Jung Il
    Sung, Ki Sun
    Kim, J-Young
    Kim, Eung Soo
    Lee, Sang-Heon
    Wang, Joon Ho
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (08) : 781 - 786
  • [49] Biomechanical and anatomical effects of an external rotational torque applied to the knee - A cadaveric study
    Csintalan, Rick P.
    Ehsan, Amirhesam
    McGarry, Michelle H.
    Fithian, Donald F.
    Lee, Thay Q.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (10): : 1623 - 1629
  • [50] Internal Bracing Augmentation for Scapholunate Interosseous Ligament Repair: A Cadaveric Biomechanical Study
    Park, Il-Jung
    Maniglio, Mauro
    Shin, Steven S.
    Lim, Dohyung
    McGarry, Michelle H.
    Lee, Thay Q.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2020, 45 (10): : 985.e1 - 985.e9