Parameter optimization strategy of LLC converter soft start-up process based on a simplified numerical calculation model

被引:2
|
作者
Li, Ning [1 ]
Cao, Yujie [1 ]
Zhang, Yan [2 ]
Li, Zhuang [1 ]
Jiang, Lin [3 ]
Zhang, Xiao-Ping [4 ]
机构
[1] Xian Univ Technol, Sch Elect Engn, Xian 710048, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Elect Engn, Xian 710049, Peoples R China
[3] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
[4] Univ Birmingham, Sch Engn, Dept Elect Elect & Syst Engn, Birmingham B15 2TT, W Midlands, England
关键词
LLC converter; Soft start-up; Numerical model; Current limiting; OPTIMAL TRAJECTORY CONTROL; RESONANT CONVERTER;
D O I
10.1016/j.egyr.2023.05.118
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
High-frequency start-up strategy is usually used to limit the current overshoot in the resonant tank of LLC converter. However, the strong coupling among start-up frequency, initial duty cycle, and current limit increases the design complexity of parameters. This paper proposes a parameter optimization strategy of the LLC converter soft start-up process based on the numerical calculation method. With this strategy, the initial switching frequency and duty cycle are determined adaptively according to the given maximum current requirements during the start-up process. The current overshoot is suppressed and soft switching is achieved in the whole process. After the second switching period, 50% duty cycle operation occurs without oscillation. Furthermore, exponential frequency reduction is used in the process, and the current overshoot limiting condition in the initial period is discussed. Finally, a 240 W LLC converter prototype is built to verify the correctness of the theoretical analysis in this paper. In terms of current limiting, soft switching, and initial switching frequency, the comprehensive performance of the soft start-up control strategy proposed in this paper is better. Compared to the traditional control strategy, the current overshoot is reduced by 45.6%. The theoretical calculation, simulation, and experimental results are consistent. (c) 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CCBY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:909 / 919
页数:11
相关论文
共 45 条
  • [21] Current Stress Optimisation Strategy for Three-phase Dual Active Bridge Converter during the Start-Up Process
    Chen, Guofu
    Mu, Xiaobin
    Wang, Xiang
    Jiao, Honglin
    Hao, Ruixiang
    Zhu, Wu
    2020 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL, AUTOMATION AND MECHANICAL ENGINEERING, 2020, 1626
  • [22] Enhanced Soft Start-up Strategy of Dual Active Bridge Converter with Constant Current Stress and Dynamically Balanced Flux Linkage
    Huang, Yao
    Hu, Jingxin
    Wang, Jingyuan
    He, Yuying
    Liu, Fei
    Ruan, Xinbo
    IEEE 15TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS, PEDG 2024, 2024,
  • [23] Multi-Structure Parameter Optimization Analysis of Soft Actuator Based on Numerical Calculation
    Wang, Songtao
    Yu, Yimeng
    Jiang, Shiyu
    Chen, Sisi
    IEEE ACCESS, 2024, 12 : 9648 - 9658
  • [24] Predictive Model-Based Process Start-Up in Pharmaceutical Continuous Granulation and Drying
    Pauli, Victoria
    Kleinebudde, Peter
    Krumme, Markus
    PHARMACEUTICS, 2020, 12 (01)
  • [25] Closed-Form Optimal Current-Limiting Curve-Based Variable Duty-Cycle Soft Start-Up Strategy for the LLC DC Transformer
    Wang, Wei
    Yin, Yanxiang
    Liu, Tong
    Wang, Nan
    Ren, Qicai
    Chen, Alian
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (10) : 12524 - 12538
  • [26] Research on start-up strategy optimization for a compact megawatt nuclear power system based on surrogate model construction and genetic algorithm
    Wang, Zheng
    Gou, Junli
    Wang, Zhenlan
    Wu, Hexin
    Jiang, Dingyu
    Shan, Jianqiang
    APPLIED THERMAL ENGINEERING, 2025, 261
  • [27] A model-based optimisation strategy for the start-up of anaerobic co-digestion processes
    Garcia-Gen, Santiago
    Wouwer, Alain Vande
    RENEWABLE ENERGY, 2021, 170 : 693 - 702
  • [28] A model-based optimisation strategy for the start-up of anaerobic co-digestion processes
    García-Gen, Santiago
    Wouwer, Alain Vande
    Renewable Energy, 2021, 170 : 693 - 702
  • [29] Start-Up Strategy-Based Resilience Optimization of Onsite Monitoring Systems Containing Multifunctional Sensors
    Zhao, Jiangbin
    Zhang, Zaoyan
    Liang, Mengtao
    Cao, Xiangang
    Cai, Zhiqiang
    MATHEMATICS, 2023, 11 (19)
  • [30] Soft Start-up Output Current of PDM-based Series-Resonant Converter for Induction Heating Application
    Herasymenko, Pavlo
    2019 IEEE 2ND UKRAINE CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (UKRCON-2019), 2019, : 570 - 575