Effect of active chilled beam layouts on ventilation performance and thermal comfort under variable heat gain conditions

被引:5
|
作者
Ming, Ru [1 ,2 ]
Mustakallio, Panu [3 ,4 ]
Kosonen, Risto [4 ,5 ]
Kaukola, Tuomas [3 ]
Kilpelainen, Simo [4 ]
Li, Baizhan [1 ,2 ]
Wu, Yuxin [6 ]
Yao, Runming [1 ,2 ,7 ]
机构
[1] Chongqing Univ, Minist Educ, Joint Int Res Lab Green Bldg & Built Environm, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Minist Sci & Technol, Natl Ctr Int Res Low Carbon & Green Bldg, Chongqing 400045, Peoples R China
[3] Halton Oy, Helsinki, Finland
[4] Aalto Univ, Dept Mech Engn, Espoo 02150, Finland
[5] Nanjing Tech Univ, Coll Urban Construct, Nanjing 211899, Peoples R China
[6] Zhejiang Sci Tech Univ, Sch Civil Engn & Architecture, Hangzhou 310018, Peoples R China
[7] Univ Reading, Sch Built Environm, Reading RG6 6DB, Berks, England
关键词
4-way active chilled beam system; Thermal comfort; Air distribution; Terminal layout; Heat gain level; AIR-FLOW PATTERN; SYSTEMS; QUALITY; ENVIRONMENT; DRAFT;
D O I
10.1016/j.buildenv.2022.109872
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The active chilled beam system has been popularly used in office and meeting rooms. There are very few studies of their terminal configuration on the thermal comfort and ventilation performance of systems with different heat gains. A comparative experimental study was implemented in mock-up office and meeting rooms to provide a comprehensive evaluation of the airflow patterns, air distribution, ventilation effectiveness, and local thermal comfort of the 4-way system. Four different terminal layouts with two types of the chilled beams (600 unit and 1200 unit sized 0.6 m x 0.6 m and 1.2 m x 0.6 m, respectively) were tested at three heat gain levels: low (46W/ m2) and medium (66W/m2) heat gains in the office room, and high (92W/m2) heat gain in the meeting room. The results revealed that the terminal layouts and heat gain levels had significant effects on air distribution and local thermal comfort. The increased heat gains generated lower heat removal effectiveness, worse indoor thermal uniformity, and increased risk of draught. Generally, the 1200-unit system performed better than that with 600 units for heat removal effectiveness and contaminant removal effectiveness. In terms of local thermal comfort, the 600-unit system generally provided higher performance than that with the 1200-unit system. The practical recommendations for the system design and operation stages are provided based on the operating range of the 4-way systems under variable terminal layouts and heat gain conditions.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Heat source effects on thermal comfort for active chilled beam systems
    Wu, Bingjie
    Cai, Wenjian
    Ji, Ke
    BUILDING AND ENVIRONMENT, 2018, 141 : 91 - 102
  • [2] Optimization Study On The Location Of An Active Chilled Beam: Effect On Thermal Comfort And Energy Consumption
    Ghanta, Nikhilesh
    Coflan, Barry
    Glicksman, Leon
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 663 - 671
  • [3] Thermal and ventilation performance of combined passive chilled beam and displacement ventilation systems
    Shan, Wenyu
    Rim, Donghyun
    ENERGY AND BUILDINGS, 2018, 158 : 466 - 475
  • [4] Effect of heat loads and ambient conditions on thermal comfort for single-sided ventilation
    David Park
    Francine Battaglia
    Building Simulation, 2015, 8 : 167 - 178
  • [5] Effect of heat loads and ambient conditions on thermal comfort for single-sided ventilation
    Park, David
    Battaglia, Francine
    BUILDING SIMULATION, 2015, 8 (02) : 167 - 178
  • [6] Comparing thermal comfort and air quality performance of two active chilled beam systems in an open-plan office
    Cehlin, Mathias
    Karimipanah, Taghi
    Larsson, Ulf
    Ameen, Arman
    JOURNAL OF BUILDING ENGINEERING, 2019, 22 : 56 - 65
  • [7] Experimental comparison of thermal conditions in office rooms: Diffuse ceiling ventilation, chilled beam system, and chilled ceiling combined with mixing ventilation
    Lestinen, Sami
    Mustakallio, Panu
    Kilpelainen, Simo
    Kosonen, Risto
    Jokisalo, Juha
    Koskela, Hannu
    Melikov, Arsen Krikor
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2020, 26 (05) : 631 - 642
  • [8] A multi-objective optimization of energy consumption and thermal comfort for active chilled beam systems
    Wu, Bingjie
    Cai, Wenjian
    PROCEEDINGS OF THE 2021 IEEE 16TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2021), 2021, : 1719 - 1723
  • [9] Evaluation of thermal comfort criteria of an active chilled beam system in tropical climate: A comparative study
    Azad, Abdus Salam
    Rakshit, Dibakar
    Wan, Man Pun
    Babu, Sushanth
    Sarvaiya, Jatin N.
    Kumar, D. E. V. S. Kiran
    Zhang, Zhe
    Lamano, Adrian S.
    Krishnasayee, Krithika
    Gao, Chun Ping
    Valliappan, Selvam
    Goh, Alice
    Seoh, Alvin
    BUILDING AND ENVIRONMENT, 2018, 145 : 196 - 212
  • [10] Numerical investigation of the thermal and ventilation performance of a combined impinging jet ventilation and passive chilled beam system
    Hu, Jun
    Kang, Yanming
    Lu, Yihang
    Yu, Jia
    Li, He
    Zhong, Ke
    BUILDING AND ENVIRONMENT, 2022, 226