Performance assessment for fiber tracking of unidirectional carbon fiber reinforced plastic by digital image correlation of X-ray computed-tomography

被引:5
|
作者
Morita, Shiryu [1 ]
Ueda, Masahito [1 ]
Takahashi, Takuya [2 ]
Kajiwara, Kentaro [3 ]
Yoshimura, Akinori [4 ]
Sugiura, Naoki [5 ]
机构
[1] Nihon Univ, Coll Sci & Technol, Dept Mech Engn, Chiyoda Ku, 1-8-14 Kanda Surugadai, Tokyo 1018308, Japan
[2] Tokyo Inst Technol, Dept Mech Engn, Meguro Ku, 2-12-1 Ookayama, Tokyo 1528550, Japan
[3] Japan Synchrotron Radiat Res Inst, 1-1-1 Kouto, Sayo, Hyogo 6795198, Japan
[4] Nagoya Univ, Dept Aerosp Engn, Chikusa Ku, Furo Cho, Nagoya, Aichi 4648603, Japan
[5] Mitsubishi Chem Corp, 4-1-2 Ushikawadori, Toyohashi, Aichi 4408601, Japan
基金
日本学术振兴会;
关键词
Polymer matrix composites; carbon fibers; fiber waviness; digital twin; KINK-BAND FORMATION; POLYMER COMPOSITES; ORIENTATION; SIMULATION; DAMAGE; MODEL; CFRP;
D O I
10.1080/09243046.2022.2071117
中图分类号
TB33 [复合材料];
学科分类号
摘要
Cross-sectional X-ray computed tomography of unidirectional carbon fiber reinforced plastic (CFRP) composites was performed at a synchrotron radiation facility. Fiber locations in each tomogram were identified and connected longitudinally via updated digital image correlation, from which a CFRP numerical model was automatically developed. Fiber-tracking accuracy was important for obtaining exact duplicates; thus, the performance was experimentally analyzed with two types of unidirectional CFRPs formed with circular or kidney-shaped cross-sectional carbon fibers. The accuracy improved and then converged to a certain value with decreasing distance between each tomogram. Better accuracy was obtained for the circular fibers. Average error in the estimated fiber locations was less than in the fiber diameter. However, errors caused overlapped fibers. The experimental results thus indicated that fiber-tracking accuracy had to be improved to develop duplicates without overlapped fibers.
引用
收藏
页码:35 / 47
页数:13
相关论文
共 50 条
  • [41] Development of a lightweight X-ray mirror using Thin Carbon-Fiber-Reinforced Plastic (CFRP)
    Awaki, Hisamitsu
    Oue, Chisato
    Iwakiri, Hayao
    Omatsu, Maki
    Yoshida, Tessei
    Yokota, Tsubasa
    Ishida, Naoki
    Matsumoto, Hironori
    SPACE TELESCOPES AND INSTRUMENTATION 2018: ULTRAVIOLET TO GAMMA RAY, 2018, 10699
  • [42] Bulk resistance and internal contacts of carbon fiber paper determined via X-ray computed tomography
    Shi, Qitong
    Feng, Cong
    Tang, Fumin
    Li, Bing
    Ming, Pingwen
    Zhang, Cunman
    MATERIALS CHEMISTRY AND PHYSICS, 2023, 296
  • [43] Porosity Content Evaluation in Carbon-Fiber/Epoxy Composites Using X-ray Computed Tomography
    Yang, Peng
    Elhajjar, Rani
    POLYMER-PLASTICS TECHNOLOGY AND ENGINEERING, 2014, 53 (03) : 217 - 222
  • [44] Microstructural analysis of short glass fiber reinforced thermoplastics based on x-ray micro-computed tomography
    Hessman, Patrick Arthur
    Riedel, Thomas
    Welschinger, Fabian
    Hornberger, Kurt
    Boehlke, Thomas
    COMPOSITES SCIENCE AND TECHNOLOGY, 2019, 183
  • [45] Microstructure analysis of quartz fiber reinforced SiO2 matrix composites by X-ray computed tomography
    Li, Chenxiao
    Xia, Tao
    Gao, Shitao
    Yan, Manling
    Chen, Yurong
    Wan, Binghong
    Li, Junsheng
    Wan, Fan
    MATERIALS CHARACTERIZATION, 2024, 209
  • [46] Porosity characterization of fiber-reinforced ceramic matrix composite using synchrotron X-ray computed tomography
    Zou, C.
    Marrow, T. J.
    Reinhard, C.
    Li, B.
    Zhang, C.
    Wang, S.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [47] Analysis of the mechanical and fracture behavior of heated ultra-high-performance fiber-reinforced concrete by X-ray computed tomography
    Rios, Jose D.
    Cifuentes, Hector
    Leiva, Carlos
    Seitl, Stanislav
    CEMENT AND CONCRETE RESEARCH, 2019, 119 : 77 - 88
  • [48] X-ray computed tomography used to measure fiber orientation in CFRP laminates
    Yoshimura, Akinori
    Hosoya, Ryohei
    Koyanagi, Jun
    Ogasawara, Toshio
    ADVANCED COMPOSITE MATERIALS, 2016, 25 (01) : 19 - 30
  • [49] Fiber orientation quantification utilizing X-ray micro-computed tomography
    Sietins, Jennifer M.
    Sun, Jessica C.
    Knorr, Daniel B., Jr.
    JOURNAL OF COMPOSITE MATERIALS, 2021, 55 (08) : 1109 - 1118
  • [50] Fiber based fast sparse sampling X-ray luminescence computed tomography
    Zhang, Wei
    Lun, Michael
    Li, Changqing
    MULTIMODAL BIOMEDICAL IMAGING XII, 2017, 10057