Lung-Optimized Deep- Learning-Based Reconstruction for Ultralow-Dose CT

被引:13
|
作者
Goto, Makoto [1 ]
Nagayama, Yasunori [2 ]
Sakabe, Daisuke [1 ]
Emoto, Takafumi [1 ]
Kidoh, Masafumi [2 ]
Oda, Seitaro [2 ]
Nakaura, Takeshi [2 ]
Taguchi, Narumi [2 ]
Funama, Yoshinori [3 ]
Takada, Sentaro [2 ]
Uchimura, Ryutaro [2 ]
Hayashi, Hidetaka [2 ]
Hatemura, Masahiro [1 ]
Kawanaka, Koichi [2 ]
Hirai, Toshinori [2 ]
机构
[1] Kumamoto Univ Hosp, Dept Cent Radiol, Chuo Ku, Kumamoto 8608556, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, 1-1-1 Honjo,Chuo Ku, Kumamoto 8608556, Japan
[3] Kumamoto Univ, Fac Life Sci, Dept Med Radiat Sci, Chuo Ku, Kumamoto 8620976, Japan
关键词
CT; Lung; Deep-learning; Image reconstruction; Ultralow-dose; FILTERED BACK-PROJECTION; SUBMILLISIEVERT CHEST CT; TASK-BASED PERFORMANCE; ITERATIVE-RECONSTRUCTION; IMAGE QUALITY; COMPUTED-TOMOGRAPHY; ALGORITHMS; PHANTOM;
D O I
10.1016/j.acra.2022.04.025
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To evaluate the image properties of lung-specialized deep-learning-based reconstruction (DLR) and its appli-cability in ultralow-dose CT (ULDCT) relative to hybrid-(HIR) and model-based iterative-reconstructions (MBIR).Materials and Methods: An anthropomorphic chest phantom was scanned on a 320-row scanner at 50-mA (low-dose-CT 1 [LDCT-1]), 25-mA (LDCT-2), and 10-mA (ULDCT). LDCT were reconstructed with HIR; ULDCT images were reconstructed with HIR (ULDCT-HIR), MBIR (ULDCT-MBIR), and DLR (ULDCT-DLR). Image noise and contrast-to-noise ratio (CNR) were quantified. With the LDCT images as reference standards, ULDCT image qualities were subjectively scored on a 5-point scale (1 = substantially inferior to LDCT-2, 3 = compara-ble to LDCT-2, 5 = comparable to LDCT-1). For task-based image quality analyses, a physical evaluation phantom was scanned at seven doses to achieve the noise levels equivalent to chest phantom; noise power spectrum (NPS) and task-based transfer function (TTF) were evaluated. Clinical ULDCT (10-mA) images obtained in 14 nonobese patients were reconstructed with HIR, MBIR, and DLR; the subjective acceptability was ranked. Results: Image noise was lower and CNR was higher in ULDCT-DLR and ULDCT-MBIR than in LDCT-1, LDCT-2, and ULDCT-HIR (p < 0.01). The overall quality of ULDCT-DLR was higher than of ULDCT-HIR and ULDCT-MBIR (p < 0.01), and almost comparable with that of LDCT-2 (mean score: 3.4 +/- 0.5). DLR yielded the highest NPS peak frequency and TTF50% for high-contrast object. In clinical ULDCT images, the subjective acceptability of DLR was higher than of HIR and MBIR (p < 0.01).Conclusion: DLR optimized for lung CT improves image quality and provides possible greater dose optimization opportunity than HIR and MBIR.
引用
收藏
页码:431 / 440
页数:10
相关论文
共 50 条
  • [31] Validation of deep learning-based CT image reconstruction for treatment planning
    Keisuke Yasui
    Yasunori Saito
    Azumi Ito
    Momoka Douwaki
    Shuta Ogawa
    Yuri Kasugai
    Hiromu Ooe
    Yuya Nagake
    Naoki Hayashi
    Scientific Reports, 13
  • [32] A Deep Learning-Based End-To-End CT Reconstruction Method
    Lu, K.
    Ren, L.
    Yin, F.
    MEDICAL PHYSICS, 2020, 47 (06) : E507 - E508
  • [33] A Machine Learning Approach to Construct a Tissue-Specific Texture Prior from Previous Full-Dose CT for Bayesian Reconstruction of Current Ultralow-Dose CT Images
    Gao, Yongfeng
    Tan, Jiaxing
    Shi, Yongyi
    Lu, Siming
    Liang, Zhengrong
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [34] LUNG THORAX - Deep Learning Reconstruction of Low-dose CT Images
    Grawert, Stephanie
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2024, 196 (08): : 783 - 784
  • [35] DEEP LEARNING-BASED SINOGRAM COMPLETION FOR LOW-DOSE CT
    Ghani, Muhammad Usman
    Karl, W. Clem
    PROCEEDINGS 2018 IEEE 13TH IMAGE, VIDEO, AND MULTIDIMENSIONAL SIGNAL PROCESSING WORKSHOP (IVMSP), 2018,
  • [36] Abdominal CT With Model-Based Iterative Reconstruction (MBIR): Initial Results of a Prospective Trial Comparing Ultralow-Dose With Standard-Dose Imaging
    Pickhardt, Perry J.
    Lubner, Meghan G.
    Kim, David H.
    Tang, Jie
    Ruma, Julie A.
    del Rio, Alejandro Munoz
    Chen, Guang-Hong
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) : 1266 - 1274
  • [37] Model-Based Iterative Reconstruction Technique for Ultralow-Dose Chest CT Comparison of Pulmonary Nodule Detectability With the Adaptive Statistical Iterative Reconstruction Technique
    Katsura, Masaki
    Matsuda, Izuru
    Akahane, Masaaki
    Yasaka, Koichiro
    Hanaoka, Shohei
    Akai, Hiroyuki
    Sato, Jiro
    Kunimatsu, Akira
    Ohtomo, Kuni
    INVESTIGATIVE RADIOLOGY, 2013, 48 (04) : 206 - 212
  • [38] Deep learning-based lung cancer detection using CT images
    Mariappan, Suguna
    Moses, Diana
    INTERNATIONAL JOURNAL OF AD HOC AND UBIQUITOUS COMPUTING, 2024, 47 (03) : 143 - 157
  • [39] Performance of ultralow-dose CT with iterative reconstruction in lung cancer screening: limiting radiation exposure to the equivalent of conventional chest X-ray imaging
    Adrian, Huber
    Julia, Landau
    Ebner, Lukas
    Yanik, Butikofer
    Lars, Leidolt
    Barbara, Brela
    Michelle, May
    Johannes, Heverhagen
    Andreas, Christe
    EUROPEAN RADIOLOGY, 2016, 26 (10) : 3643 - 3652
  • [40] Deep Learning-Based Pseudo CT Reconstruction for MR Only-Guided Radiation Therapy of Lung SBRT
    Olberg, S.
    Zhang, H.
    Green, O. L.
    Mazur, T. R.
    Yang, D.
    Hugo, G. D.
    Bradley, J. D.
    Mutic, S.
    Park, J.