TL-SDA: A designed toolkit for the deconvolution analysis of thermoluminescence glow curves

被引:3
|
作者
Sadek, A. M. [1 ]
Farag, M. A. [1 ]
Abd El-Hafez, A. I. [1 ]
Kitis, G. [2 ]
机构
[1] Natl Inst Stand, Ionizing Radiat Metrol Dept, Giza, Egypt
[2] Aristotle Univ Thessaloniki, Phys Dept, Nucl Phys & Elementary Particles Phys Sect, Thessaloniki, Greece
关键词
Thermoluminescence; Deconvolution analysis; OTOR; THERMO-LUMINESCENCE; CRITICAL-LOOK; LEVENBERG-MARQUARDT; KINETIC-MODELS; EXPRESSIONS; ALGORITHM; SYSTEMS; 1ST;
D O I
10.1016/j.apradiso.2024.111202
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In the present study, a graphical user interface (GUI) toolkit has been developed to analyze the thermoluminescence (TL) glow -curve and evaluate the trapping parameters using TL expression based on the one -trap onerecombination model. The basic idea of the deconvolution analysis in the developed toolkit is based on performing a sequence of successful fits, where the information provided by each fit is used by the next fit until the deconvolution of the entire glow curve approaches an optimum solution. The starting values and ranges of the fitting parameters can be controlled and adjusted to improve the deconvolution analysis of complex structure glow curves. The designed toolkit is also supported by the background -subtraction option to improve the analysis at low irradiation dose levels. The expanded uncertainty at the 95 % confidence level of the fitted trapping parameters is also provided. All the evaluations performed using the designed toolkit are allowed to be extracted into an Excel spreadsheet. The TL-SDA toolkit can be freely downloaded from: TLSDA_v1 - File ExchangeMATLAB Central (https://www.mathworks.com/matlabcentral/fileexchange/154136-tlsda_v1-1)
引用
收藏
页数:10
相关论文
共 50 条
  • [31] ANALYSIS OF THERMOLUMINESCENCE KINETICS OF CAF2(TM) PEAKS WITH GLOW CURVE DECONVOLUTION
    BACCI, C
    BERNARDINI, P
    DIDOMENICO, A
    FURETTA, C
    RISPOLI, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 286 (1-2): : 295 - 300
  • [32] Thermoluminescence glow curve deconvolution and its statistical analysis using the flexibility of spreadsheet programs
    van Dijk, J. W. E.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 332 - 338
  • [33] KINETIC ANALYSIS OF THERMOLUMINESCENCE GLOW CURVES IN FELDSPAR: EVIDENCE FOR A CONTINUOUS DISTRIBUTION OF ENERGIES
    Pagonis, Vasilis
    Morthekai, P.
    Kitis, George
    GEOCHRONOMETRIA, 2014, 41 (02): : 168 - 177
  • [34] STUDY OF AGING EFFECTS IN LIF-MG, TI BY ANALYSIS OF THERMOLUMINESCENCE GLOW CURVES
    BOS, AJJ
    PITERS, TM
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 21 (01): : 163 - 167
  • [35] Thermoluminescence analysis for detection of irradiated food -: Effects of dose rate on the glow curves of quartz
    Soika, C
    Delincée, H
    LEBENSMITTEL-WISSENSCHAFT UND-TECHNOLOGIE-FOOD SCIENCE AND TECHNOLOGY, 2000, 33 (06): : 440 - 443
  • [36] Simultaneous analysis of the glow curves of thermoluminescence and thermally stimulated exo-electron emission
    Sakurai, T
    Tomita, A
    Fukuda, Y
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1999, 32 (17) : 2290 - 2295
  • [37] Use of a Machine Learning based method to detect anomalous Thermoluminescence Glow Curves (TL-GC) in routine Dosimetry Services
    Arquero, O.
    Berenguer-Antequera, J.
    Benavente, J. F.
    RADIATION MEASUREMENTS, 2024, 178
  • [38] Recent Developments in Computerised Analysis of Thermoluminescence Glow Curves: Software Codes, Mechanisms and Dosimetric Applications
    Horowitz, Y. S.
    Oster, L.
    Reshes, G.
    Nemirovsky, D.
    Ginzburg, D.
    Biderman, S.
    Bokobza, Y.
    Sterenberg, M.
    Eliyahu, I
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (12) : 821 - 842
  • [39] Analysis of the thermoluminescence glow curves of a brown microcline - Effects of optical bleaching upon the trap distribution
    Sakurai, T
    Gartia, RK
    RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) : 479 - 482
  • [40] A comparative study of glow curves in photo-transferred and pre-dose sensitized thermoluminescence (PTTL and TL) in LiF:Mg, Ti
    Piters, TM
    Yoshimura, EM
    Sunta, CM
    Okuno, E
    Umisedo, NK
    Diaz, MP
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 1995, 136 (1-4): : 301 - 306