Rapid determination of biogenic amines in ossotide injections by microfluidic chip-mass spectrometry platform: Optimization of microfluidic chip derivatization using response surface methodology

被引:0
|
作者
Tang, Minmin [1 ,2 ]
Tan, Li [3 ]
Zhang, Mei [3 ]
Shi, Haiwei [3 ]
Zhao, Yaju [4 ]
Xu, Danke [1 ]
Zou, Jie [2 ]
机构
[1] Nanjing Univ, Sch Chem & Chem Engn, State Key Lab Analyt Chem Life Sci, Nanjing 210023, Peoples R China
[2] Jiangsu Prod Qual Testing & Inspect Inst, Nanjing 210007, Jiangsu, Peoples R China
[3] Jiangsu Inst Food & Drug Control, NMPA Key Lab Impur Profile Chem Drugs, Nanjing 210008, Peoples R China
[4] Zhejiang Gongshang Univ, Zhejiang Engn Res Inst Food & Drug Qual & Safety, Sch Management & Ebusiness, Hangzhou 310018, Peoples R China
基金
中国国家自然科学基金;
关键词
Microfluidic chip; MS; Biogenic amines; Ossotide injections; Response surface design; SPE; QUADRUPOLE-TIME;
D O I
10.1016/j.microc.2024.109989
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The microfluidic-chip mass spectrometry (MS) platform was developed for the rapid and automatic determination of 10 biogenic amines (BAs) in ossotide injections. The microfluidic chip was primarily consisted of a square unit for derivatization and a solid phase extraction (SPE) unit. The derivatization unit could achieve automatic mixing and reaction between sample and derivatization reagents, after which the targets were purified and enriched in SPE unit, further improving the sensitivity. To select the optimal derivatization conditions, four major parameters affecting derivatization in the microfluidic chip were optimized using Box-Behnken response surface design. On -chip derivatization unit enabled the shortest derivatization time by thorough solution mixing. There is no additional pretreatment required for the entire process. The developed method achieved satisfactory limits of detection (0.045-0.855 ng/mL) and limits of quantitation (0.156-3.11 ng/mL). The recoveries of the method ranged from 75.0 % to 106 % when coupled in -line with MS. This pretreatment chip -MS platform was successfully applied to BAs detection in the commercially available ossotide injections, demonstrating the prospects of this technique as a potential method for the rapid determination. The results of BAs in ossotide injections provide a basis for the formulation of the limit standard in pharmaceutical preparations.
引用
收藏
页数:8
相关论文
共 26 条
  • [21] Headspace Liquid-Phase Microextraction Followed by Gas Chromatography-Mass Spectrometry for Determination of Furanic Compounds in Baby Foods and Method Optimization Using Response Surface Methodology
    Habibi, Hossein
    Mohammadi, Abdorreza
    Hoseini, Hedayat
    Mohammadi, Mehrdad
    Azadniya, Ebrahim
    [J]. FOOD ANALYTICAL METHODS, 2013, 6 (04) : 1056 - 1064
  • [22] Simultaneous Determination of Seven Biogenic Amines in Foodstuff Samples Using One-Step Fluorescence Labeling and Dispersive Liquid-Liquid Microextraction Followed by HPLC-FLD and Method Optimization Using Response Surface Methodology
    Wu, Hongliang
    Li, Guoliang
    Liu, Shucheng
    Ji, Zhongyin
    Zhang, Qiulong
    Hu, Na
    Suo, Yourui
    You, Jinmao
    [J]. FOOD ANALYTICAL METHODS, 2015, 8 (03) : 685 - 695
  • [23] Optimization of HS-SPME Using Artificial Neural Network and Response Surface Methodology in Combination with Experimental Design for Determination of Volatile Components by Gas Chromatography-Mass Spectrometry in Korla Pear Juice
    Fang Zhang
    Ping Zhan
    Honglei Tian
    Zhisheng Wei
    Peng Wang
    [J]. Food Analytical Methods, 2018, 11 : 2218 - 2228
  • [24] Optimization of HS-SPME Using Artificial Neural Network and Response Surface Methodology in Combination with Experimental Design for Determination of Volatile Components by Gas Chromatography-Mass Spectrometry in Korla Pear Juice
    Zhang, Fang
    Zhan, Ping
    Tian, Honglei
    Wei, Zhisheng
    Wang, Peng
    [J]. FOOD ANALYTICAL METHODS, 2018, 11 (08) : 2218 - 2228
  • [25] Highly sensitive and selective pre-column derivatization high-performance liquid chromatography approach for rapid determination of triterpenes oleanolic and ursolic acids and application to Swertia species: Optimization of triterpenic acids extraction and pre-column derivatization using response surface methodology
    Li, Guoliang
    Zhang, Xiaolong
    You, Jinmao
    Song, Cuihua
    Sun, Zhiwei
    Xia, Lian
    Suo, Yourui
    [J]. ANALYTICA CHIMICA ACTA, 2011, 688 (02) : 208 - 218
  • [26] Method development and optimization for dispersive liquid-liquid microextraction factors using the response surface methodology with desirability function for the ultra-high performance liquid chromatography quadrupole time of flight mass spectrometry determination of organic contaminants in water samples: risk and greenness assessment
    Makwakwa, Tlou Auguston
    Moema, Elsie Dineo
    Makudali Msagati, Titus Alfred
    [J]. Analytical Methods, 2024, 16 (44) : 7598 - 7612